HRID1963352

反应详情

EQUATION

反应方程式

HRID 1963352 的结构方程式

AUXILIARIES

试剂、催化剂与溶剂

1

CONDITIONS

反应条件

温度
50 °C

PROCEDURE

实验过程

Ethyl potassium malonate (1.75 g, 10.3 mmol) and MgCl2 (0.665 g, 6.88 mmol) were added to dry THF (50 mL). The reaction flask was stirred vigorously 4 h at 50° C. (flask 1). 2-(Cyclohexylmethyl)-1-(methoxycarbonyl)piperidine-4-carboxylic acid (1.95 g, 6.88 mmol) (Reference Compound 8) and carbonyldiimidazole (1.34 g, 8.26 mmol) were added to dry THF (50 mL) at 5° C. (flask 2). The contents of flask 2 was added to flask 1 at room temperature. The reaction mixture was evaporated to remove most of the THF. The crude was partitioned between water and diethyl ether. The organic phase was isolated, dried with MgSO4, filtered through Celite® and the solvent was evaporated. The residue was purified by automated column chromatography using the Biotage equipment. Gradient eluation using ethylacetate-heptane, started 15-85 and ended 40-60 which gave trans-methyl 2-(cyclohexylmethyl)-4-(3-ethoxy-3-oxopropanoyl)piperidine-1-carboxylate (0.38 g, 16%) and cis-methyl 2-(cyclohexylmethyl)-4-(3-ethoxy-3-oxopropanoyl)piperidine-1-carboxylate (1.28 g, 53%). Trans-isomer: 1H NMR (600 MHz, cdcl3) δ 0.88 (d, 2H), 0.99-1.32 (m, 8H), 1.38-1.56 (m, 2H), 1.68 (dd, 8H), 2.80 (t, 2H), 3.45 (s, 2H), 3.66 (s, 3H), 3.93-4.21 (m, 3H), 4.47 (d, 1H). Cis-isomer 1H NMR (600 MHz, cdcl3) δ 0.72-0.95 (m, 2H), 1.04-1.31 (m, 8H), 1.38-1.49 (m, 1H), 1.53-1.69 (m, 6H), 1.70-1.92 (m, 3H), 2.02 (dt, 1H), 2.61-2.71 (m, 1H), 2.95-3.07 (m, 1H), 3.48 (s, 2H), 3.66 (s, 3H), 3.85 (dd, 1H), 4.09-4.21 (m, 3H).

WORKUP

后处理

  1. additionThe contents of flask 2 was added to flask 1 at room temperature
  2. customThe reaction mixture was evaporated
  3. customto remove most of the THF
  4. customThe crude was partitioned between water and diethyl ether
  5. customThe organic phase was isolated
  6. dry with materialdried with MgSO4
  7. filtrationfiltered through Celite®
  8. customthe solvent was evaporated
  9. customThe residue was purified by automated column chromatography