HRID497595

反应详情

EQUATION

反应方程式

HRID 497595 的结构方程式

AUXILIARIES

试剂、催化剂与溶剂

1

CONDITIONS

反应条件

温度
10 °C

PROCEDURE

实验过程

0.23 cm3 of butyryl chloride is added to 1 g of 4-chloro-1H-indazole-3-amine, prepared as described in patent EP 90 972, in 10 cm 3 of pyridine, cooled to about 10° C. The temperature is allowed to return to about 19° C. over 17 hours. The reaction medium is evaporated under reduced pressure (2 kPa; 50° C.). The residue is taken up in 25 cm3 of ethyl acetate and 25 cm3 of distilled water. The organic phase is washed with 2×25 cm3 of distilled water and with 25 cm3 of saturated aqueous sodium chloride solution. The organic phase is dried over magnesium sulphate, filtered through a sinter funnel and then evaporated under reduced pressure (2 kPa; 50° C.). The residue is purified by chromatography under an argon pressure of 50 kPa, on a column of silica gel (particle size 40-60 μm; diameter 4 cm), eluting with a dichloromethane/methanol mixture (99/1 by volume) and collecting 30 cm3 fractions. The fractions containing the expected product are combined and evaporated under reduced pressure (2 kPa; 50° C.). 80 mg of N-[4-chloro-1H-indazol-3-yl]butanamide are thus obtained in the form of a white solid melting at 198° C.

WORKUP

后处理

  1. customprepared
  2. customThe reaction medium is evaporated under reduced pressure (2 kPa; 50° C.)
  3. washThe organic phase is washed with 2×25 cm3 of distilled water and with 25 cm3 of saturated aqueous sodium chloride solution
  4. dry with materialThe organic phase is dried over magnesium sulphate
  5. filtrationfiltered through a sinter funnel
  6. customevaporated under reduced pressure (2 kPa; 50° C.)
  7. customThe residue is purified by chromatography under an argon pressure of 50 kPa
  8. washon a column of silica gel (particle size 40-60 μm; diameter 4 cm), eluting with a dichloromethane/methanol mixture (99/1 by volume)
  9. customcollecting 30 cm3 fractions
  10. additionThe fractions containing the expected product
  11. customevaporated under reduced pressure (2 kPa; 50° C.)