29656-63-1CCCCCClSQCZQTSHSZLZIQ-UHFFFAOYSA-N29656-63-1、543-59-9DTXSID40870603CHEMBL3480390.8834 at 68 °F (USCG, 1999) - Less dense than water; will float
0.8820 g/cu cm at 20 °C
Straw- to purple-colored liquid. Density: 0.88 at 20 °C, 95% distills between 85 and 109 °C, wt/gal 7.33 lb. Refractive index (20 °C) 1.406. Insoluble in water; water azeotrope at 77-82 °C approx 90% C5H11Cl, miscible with alcohol and ether /Amyl chlorides, mixed/
Liquid
Colorless liquid
In water, 197 mg/L at 25 °C
Insoluble in water
Miscible with alcohol, ether
Miscible with ethanol, ethyl ether; soluble in benzene, carbon tetrachloride; very soluble in chloroform
34 °F (USCG, 1999)
13 °C
12 °C (54 °F) - closed cup
55 °F (13 °C) - closed cup
55 °F (13 °C) (Open Cup)
Sicherheitsangaben dienen nur zur Orientierung und ersetzen weder das Sicherheitsdatenblatt (SDB) des Lieferanten noch geltende Vorschriften oder eine fachliche Bewertung.
Danger
H225: Highly Flammable liquid and vapor [Danger Flammable liquids];H302: Harmful if swallowed [Warning Acute toxicity, oral];H312: Harmful in contact with skin [Warning Acute toxicity, dermal];H332: Harmful if inhaled [Warning Acute toxicity, inhalation]
P210, P233, P240, P241, P242, P243, P261, P264, P270, P271, P280, P301+P317, P302+P352, P303+P361+P353, P304+P340, P317, P321, P330, P362+P364, P370+P378, P403+P235, and P501 (click each P-code to see the statement)
Danger
Chemical: Pentane, 1-chloro-
Pentane, 1-chloro-: HSNO Approval: HSR001020 Approved with controls
The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)
Special Hazards of Combustion Products: Irritating hydrogen chloride and toxic phosgene may be formed in fires. (USCG, 1999)
· HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.;· Vapors may form explosive mixtures with air.;· Vapors may travel to source of ignition and flash back.;· Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.).;· Vapor explosion hazard indoors, outdoors or in sewers.;· Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.;· Runoff to sewer may create fire or explosion hazard.;· Containers may explode when heated.;· Many liquids will float on water.
Used as a chemical intermediate; [Hawley]
For amyl mercaptan (USEPA/OPP Pesticide Code: 100701) there are 0 labels match. /SRP: Not registered for current use in the USA, but approved pesticide uses may change periodically and so federal, state and local authorities must be consulted for currently approved uses./
Chemical intermediate.
Prepared from 1-pentanol and concentrated HCl in sealed tube at 120 °C.
(1) Distillation of amyl alcohol with salt and sulfuric acid, (2) addition of hydrochloric acid to alpha-amylene.
Wird geladen…
226 °F at 760 mmHg (USCG, 1999)
107.9 °C
-146 °F (USCG, 1999)
-99 °C
32.9 [mmHg]
32.9 mm Hg at 25 °C
Dangerous fire hazard when exposed to heat or flame ... .
Flammable.
Inhalation causes mild irritation of mucous membranes. Ingestion of liquid or contact with skin or eyes causes mild irritation. (USCG, 1999)
· May cause toxic effects if inhaled or absorbed through skin.;· Inhalation or contact with material may irritate or burn skin and eyes.;· Fire will produce irritating, corrosive and/or toxic gases.;· Vapors may cause dizziness or asphyxiation, especially when in closed or confined areas.;· Runoff from fire control or dilution water may cause environmental contamination.
Flammable liquid; High concentrations may be narcotic; [Hawley] A skin, eye, nose, and throat irritant; Emergency medical treatment: see Hydrocarbons; [HSDB] A mild mucous membrane irritant; May cause CNS depression at high vapor concentrations; [CAMEO]
This action promulgates standards of performance for equipment leaks of Volatile Organic Compounds (VOC) in the Synthetic Organic Chemical Manufacturing Industry (SOCMI). The intended effect of these standards is to require all newly constructed, modified, and reconstructed SOCMI process units to use the best demonstrated system of continuous emission reduction for equipment leaks of VOC, considering costs, non air quality health and environmental impact and energy requirements. Amyl chloride is produced, as an intermediate or final product, by process units covered under this subpart.
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient.;SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. Do not use dry chemical extinguishers to control fires involving nitromethane (UN1261) or nitroethane (UN2842).;LARGE FIRE: Water spray, fog or alcohol-resistant foam. Avoid aiming straight or solid streams directly onto the product. If it can be done safely, move undamaged containers away from the area around the fire.;FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.;· Keep unauthorized personnel away.;· Stay upwind, uphill and/or upstream.;· Ventilate closed spaces before entering, but only if properly trained and equipped.
· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.;· All equipment used when handling the product must be grounded.;· Do not touch or walk through spilled material.;· Stop leak if you can do it without risk.;· Prevent entry into waterways, sewers, basements or confined areas.;· A vapor-suppressing foam may be used to reduce vapors.;· Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers.;· Use clean, non-sparking tools to collect absorbed material.;Large Spill;· Dike far ahead of liquid spill for later disposal.;· Water spray may reduce vapor, but may not prevent ignition in closed spaces.
INHALATION: remove to fresh air; apply artificial respiration if required.;EYES: flush with water.;SKIN: wash well with soap and water.;INGESTION: induce vomiting; give water. (USCG, 1999)
General First Aid:;· Call 911 or emergency medical service.;· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.;· Move victim to fresh air if it can be done safely.;· Administer oxygen if breathing is difficult.;· If victim is not breathing:;-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.;-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).;-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.;· Remove and isolate contaminated clothing and shoes.;· For minor skin contact, avoid spreading material on unaffected skin.;· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.;· For severe burns, immediate medical attention is required.;· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.;· Keep victim calm and warm.;· Keep victim under observation.;· For further assistance, contact your local Poison Control Center.;· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.;Specific First Aid:;· Wash skin with soap and water.
Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Advice for firefighters: Wear self contained breathing apparatus for fire fighting if necessary.
Use water spray to cool unopened containers.
To fight fire, use foam, /carbon dioxide/, dry chemical.
If material on fire or involved in fire: Do not extinguish fire unless flow can be stopped. Use water in flooding quantities as fog. Solid streams of water may spread fire. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible. Use foam, dry chemical, or carbon dioxide.
ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapors accumulating to form explosive concentrations. Vapors can accumulate in low areas. Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Methods and materials for containment and cleaning up: Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet-brushing and place in container for disposal according to local regulations.
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material.;LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)
SRP: Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in air, soil or water; effects on animal, aquatic and plant life; and conformance with environmental and public health regulations. If it is possible or reasonable use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination.
Product: Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting as this material is highly flammable. Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material; Contaminated packaging: Dispose of as unused product.
ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapors accumulating to form explosive concentrations. Vapors can accumulate in low areas. Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Precautions for safe handling: Avoid contact with skin and eyes. Avoid inhalation of vapor or mist. Use explosion-proof equipment. Keep away from sources of ignition - No smoking. Take measures to prevent the build up of electrostatic charge.
Appropriate engineering controls: Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
For more Preventive Measures (Complete) data for n-Amyl chloride (6 total), please visit the HSDB record page.
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.;LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).;FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Immediate precautionary measure;· Isolate spill or leak area for at least 50 meters (150 feet) in all directions.;Large Spill;· Consider initial downwind evacuation for at least 300 meters (1000 feet).;Fire;· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.
Protective goggles or face shield; rubber gloves. (USCG, 1999)
Eye/face protection: Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection: Handle with gloves.
Body Protection: Complete suit protecting against chemicals. Flame retardant antistatic protective clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection: Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multipurpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
TERRESTRIAL FATE: Based on a classification scheme(1), an estimated Koc value of 240(SRC), determined from a log Kow of 2.73(2) and a regression-derived equation(3), indicates that n-amyl chloride is expected to have moderate mobility in soil(SRC). Volatilization of n-amyl chloride from moist soil surfaces is expected to be an important fate process(SRC) given a estimated Henry's Law constant of 2.38X10-2 atm-cu m/mole(4). n-Amyl chloride is expected to volatilize from dry soil surfaces(SRC) based upon a vapor pressure of 32.9 mm Hg at 25 °C(5). Using sewage sludge from domestic sewage treatment plants, a 2.8% Theoretical BOD was reported in 24 hours(6), suggesting that biodegradation is not an important environmental fate process in soil(SRC).
AQUATIC FATE: Based on a classification scheme(1), an estimated Koc value of 240(SRC), determined from a log Kow of 2.73(2) and a regression-derived equation(3), indicates that n-amyl chloride is expected to adsorb to suspended solids and sediment(SRC). Volatilization from water surfaces is expected(4) based upon a Henry's Law constant of 2.38X10-2 atm-cu m/mole(5). Using this Henry's Law constant and an estimation method(4), volatilization half-lives for a model river and model lake are 3 hours and 4 days, respectively(SRC). According to a classification scheme(6), an estimated BCF of 30(SRC), from its log Kow(2) and a regression-derived equation(3), suggests the potential for bioconcentration in aquatic organisms is low to moderate(SRC). Using sludge from domestic sewage treatment plants, a 2.8% Theoretical BOD was reported in 24 hours(7), suggesting that biodegradation is not an important environmental fate process in water(SRC).
ATMOSPHERIC FATE: According to a model of gas/particle partitioning of semivolatile organic compounds in the atmosphere(1), n-amyl chloride, which has a vapor pressure of 32.9 mm Hg at 25 °C(2), is expected to exist solely as a vapor in the ambient atmosphere. Vapor-phase n-amyl chloride is degraded in the atmosphere by reaction with photochemically-produced hydroxyl radicals(SRC); the half-life for this reaction in air is estimated to be 5 days(SRC), calculated from its rate constant of 3.36X10-12 cu cm/molecule-sec at 25 °C(3). n-Amyl chloride does not contain chromophores that absorb at wavelengths >290 nm(4) and, therefore, is not expected to be susceptible to direct photolysis by sunlight(SRC).
IDENTIFICATION AND USE: 1-Chloropentane is a liquid which is used as a chemical intermediate. HUMAN STUDIES: There are no data available. ANIMAL STUDIES: Significant dose related decreases in serum triglyceride levels at 2 hours was observed following the administration of 1-chloropentane in male mice and rats. This effect was also observed in vitro in freshly prepared isolated hepatocytes. 1-Chloropentane induced positive genotoxic effects in wing spot number frequency test in Drosophila melanogaster even though it showed only moderate toxicity.
The Koc of n-amyl chloride is estimated as 240(SRC), using a log Kow of 2.73(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that n-amyl chloride is expected to have moderate mobility in soil(SRC).
AEROBIC: Aerobic cultures containing n-amyl chloride inoculated with sewage from three different treatment plants, reached 1.5, 1.8, and 2.8% of the theoretical oxygen demand in 6, 12, and 24 hours, respectively(1).
PURE CULTURE: Corynebacterium sp., Acinetobacter sp., Arthrobacter sp.(1), and Alcaligenes faecalis(2) have been shown to degrade n-amyl chloride.
An estimated BCF of 30 was calculated in fish for n-amyl chloride(SRC), using a log Kow of 2.73(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low to moderate(SRC).
The Henry's Law constant for n-amyl chloride is 2.38X10-2 atm-cu m/mole(1). This Henry's Law constant indicates that n-amyl chloride is expected to volatilize rapidly from water surfaces(2). Based on this Henry's Law constant, the volatilization half-life from a model river (1 m deep, flowing 1 m/sec, wind velocity of 3 m/sec)(2) is estimated as 3 hours(SRC). The volatilization half-life from a model lake (1 m deep, flowing 0.05 m/sec, wind velocity of 0.5 m/sec)(2) is estimated as 4 days(SRC). n-Amyl chloride's Henry's Law constant indicates that volatilization from moist soil surfaces may occur(SRC). n-Amyl chloride is expected to volatilize from dry soil surfaces(SRC) based upon a vapor pressure of 32.9 mm Hg(3).
/GENOTOXICITY/ Halogenated aliphatic compounds were evaluated for toxic and genotoxic effects in the somatic mutation and recombination test employing Drosophila melanogaster. ... Toxicity was evaluated as the number of hatched adulthood in the presence of tested chemicals and the lethal concentration of 50% (LC50) was then calculated. ... 1,2-dichloroethane, 1,2- dichloropropane, 1,2- dichlorobutane and 1-chloropentane induced positive effects in wing spot number frequency even though these chemicals showed only moderate toxicity in our test.
/OTHER TOXICITY INFORMATION/ The role of the chlorinated alkane solvent effect on the inhibition of hepatic triglyceride secretion was investigated using male Swiss Webster mice and male Sprague Dawley rats. Triglycerides were measured in serum of treated animals or in supernatants of isolated hepatocytes exposed to solvents and tritiated glycerol. Two hours following carbon tetrachloride injection, triglyceride levels were reduced significantly to 42 percent of control values and to 15 percent by 8 hours. Methylene chloride caused a more rapid decline in serum triglyceride concentration. Significant dose related decreases in serum triglyceride levels at 2 hours followed the administration of 1-chloropropane, 1-chlorobutane, 1-chloropentane, 1-chlorohexane, 1,2-dichloroethane, 1,3-dichloropropane, 1,4-dichlorobutane, and 1,5-dichloropentane. The shorter chain, less lipid soluble solvents were the more potent at decreasing triglyceride secretion in vivo. In freshly prepared isolated hepatocyte systems, the relationship between 50 percent inhibitory concentration and lipid solubility was opposite to that observed in-vivo. The more lipid soluble solvents were the more potent at decreasing secretion in-vitro. The authors suggest from this finding that nonspecific solvent effects on membrane integrity may be important in the inhibition of triglyceride secretion. The chlorinated alkane induced development of fatty liver through inhibition of triglyceride secretion may be related to lipid solubility of the chemical rather than to its metabolism to free radicals.
Chemical: Pentane, 1-chloro-
Pentane, 1-chloro-: HSNO Approval: HSR001020 Approved with controls
The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)
This action promulgates standards of performance for equipment leaks of Volatile Organic Compounds (VOC) in the Synthetic Organic Chemical Manufacturing Industry (SOCMI). The intended effect of these standards is to require all newly constructed, modified, and reconstructed SOCMI process units to use the best demonstrated system of continuous emission reduction for equipment leaks of VOC, considering costs, non air quality health and environmental impact and energy requirements. Amyl chloride is produced, as an intermediate or final product, by process units covered under this subpart.