StartseiteMCPWorkbenchSkills
StartseiteWorkbenchBenachrichtigungenMein Bereich
llms.txt · MCP-AnleitungDatenschutz · Nutzungsbedingungen · Supportv1.8.3
  1. Startseite
  2. /Verbindung

Bleibis(tetrafluoroborat)

Lead fluoroborate

HCID 12598180
Neue Reaktion
Drucken

Daten werden ergänzt – lade die Seite später neu, um den aktuellen Stand zu sehen

GrundinformationenÜberblickNamen und BezeichnerEigenschaftenSicherheit und RegulatorischesChemie und IndustrieZugehörige ReaktionenNotizen zur Verbindung
TeilstruktursucheÄhnliche Strukturen suchen

Grundinformationen

CAS
13814-96-5
Standard-SMILES
F[B-](F)(F)F.F[B-](F)(F)F.[Pb+2]
InChIKey
UQGXAENNKXXYNF-UHFFFAOYSA-N
Summenformel
Pb(BF4)2
Durchschnittliche Molmasse
381 g/mol
Monoisotopische Masse
381,98249

Überblick

Lead fluoborate is an odorless colorless liquid. An aqueous solution. Sinks and mixes with water. (USCG, 1999)

Namen und Bezeichner

Bevorzugter Name
Lead fluoroborate
IUPAC
lead(2+) ditetrafluoroborate
Lokaler Name
Bleibis(tetrafluoroborat)
Englischer Name
Lead(II) tetrafluoroborate
Summenformel
BF4Pb+
Molmasse
294

Namen und Synonyme

13814-96-5LEAD FLUOROBORATELead tetrafluoroborateLead bis(tetrafluoroborate)DTXSID9065651LEAD FLUOROBORATE [HSDB]Lead fluoborateLead borofluorideUNII-WAX1E0VJ84HSDB 1991Fluoborato de plomoEINECS 237-486-0
Weitere Namen anzeigen
50t. % in H2OEADFLUOBORATEleadborofluorideleadboronfluorideLEAD(+2)BOROFLUORIDELEAD(II) FLUOROBORATEleadtetrafluoroborateLeadFluoborateSolution
UN2291Lead fluoroboric acidRefChem:152636EC 237-486-0Lead(2+) tetrafluoroborateBorate(1-), tetrafluoro-, lead (2+) (2:1)Fluoborato de plomo (Spanish)DTXCID601477292

Datenbank-Bezeichner

CAS
13814-96-5
PubChem CID
12598180
DTXSID
DTXSID9065651
UNII
WAX1E0VJ84

Eigenschaften

Berechnete StruktureigenschaftenWird ergänzt

Polarare Oberfläche (TPSA)
0 Ų
H-Brücken-Donoren
0
H-Brücken-Akzeptoren
10
Frei drehbare Bindungen
0
Schwere Atome
11
Formalladung
0
Komplexität
19,1

Experimentelle und physikochemische Eigenschaften

Chemical Classes · 2 Einträge

Metals -> Lead Compounds, Inorganic

Carcinogens

Density · 2 Einträge

1.75 at 68 °F (USCG, 1999) - Denser than water; will sink

1.75 @ 20°C

SolubilitySoluble in water
CorrosivityCorrosive to aluminum
DecompositionWhen heated to decomposition it emits very toxic fumes of /lead, hydrogen fluoride and boron oxides/.
Physical Description · 2 Einträge

Lead fluoborate is an odorless colorless liquid. An aqueous solution. Sinks and mixes with water. (USCG, 1999)

Crystalline powder; [HSDB]

Other Experimental Properties · 5 Einträge

Colorless, faint odored liquid; will corrode most metals; Specific gravity: 1.75 at 20 °C (liq) /Solution/

Only stable in aqueous solution.

Natural lead is a mixture of four stable isotopes: Pb-204 (1.4%), Pb-206 (25.2%), Pb-207 (21.7%) and Pb-208 (51.7%). Lead isotopes are the end-products of each of the three series of naturally occurring radioactive elements: Pb-206 for the uranium series, Pb-207 for the actinium series and Pb-208 for the thorium series. Forty-three other isotopes of lead, all of which are radioactive, are recognized.

Sicherheit und Regulatorisches

Sicherheitsangaben dienen nur zur Orientierung und ersetzen weder das Sicherheitsdatenblatt (SDB) des Lieferanten noch geltende Vorschriften oder eine fachliche Bewertung.

GHS-Klassifizierung

GHS Classification · 6 Einträge

Danger

H302+H332 (86.7%): Harmful if swallowed or if inhaled [Warning Acute toxicity, oral; acute toxicity, inhalation]

P203, P260, P261, P264, P270, P271, P273, P280, P301+P317, P301+P330+P331, P302+P361+P354, P304+P340, P305+P354+P338, P316, P317, P318, P319, P321, P330, P363, P391, P403+P233, P405, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 45 reports by companies from 4 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Danger

H341: Suspected of causing genetic defects [Warning Germ cell mutagenicity]

Gefahrenhinweise

Regulatory Information · 6 Einträge

Chemical: Borate(1-), tetrafluoro-, lead(2+) (2:1)

REACH registered substance: Lead bis(tetrafluoroborate) (EC: 237-486-0)

Restricted substance: Lead bis(tetrafluoroborate)

Substance: Lead bis(tetrafluoroborate)

Borate(1-), tetrafluoro-, lead(2+) (2:1): Does not have an individual approval but may be used as a component in a product covered by a group standard. It is not approved for use as a chemical in its own right.

The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)

Other Safety InformationIMAP assessments - Borate(1-), tetrafluoro-, lead(2+) (2:1): Human health tier II assessment
DOT LabelPoison
Fire HazardsSpecial Hazards of Combustion Products: Toxic and irritating hydrogen fluoride gas may form in fire. (USCG, 1999)

Chemie und Industrie

Pharmakologische Informationen

Metabolism/Metabolites · 1 Eintrag

Lead is absorbed following inhalation, oral, and dermal exposure. It is then distributed mainly to the bones and red blood cells. In the blood lead may be found bound to serum albumin or the metal-binding protein metallothionein. Organic lead is metabolized by cytochrome P-450 enzymes, whereas inorganic lead forms complexes with delta-aminolevulinic acid dehydratase. Lead is excreted mainly in the urine and faeces. (L136)

Verwendung und Herstellung

Uses · 6 Einträge

Electroplating solution for coating metal objects with lead; curing agent for epoxy resins; catalyst in production of linear polyesters; [HSDB]

Electroplating [Category: Plate]

Electroplating soln for coating metal objects with lead; curing agent for epoxy resins; catalyst in production of linear polyesters

In metal finishing

Electroplating where speed and quality are important. Sound insulators are made as lead-plastic laminates by plating lead from a fluoroborate bath to 0.5 mm on a copper-coated nylon or polypropylene film. Solder is plated in solutions containing a mixture of lead and tin fluoroborate, coating the solder with a Pb-Sn alloy.

Salt for electroplating lead; can be mixed with stannous fluoborate to electroplate any composition of tin and lead as an alloy.

U.S. Exports(1984) 2.53X10+9 g
U.S. Imports(1984) 1.75X10+9 g
U.S. ProductionProduction volume for non-confidential chemicals reported under the 2006 Inventory Update Rule. Chemical: Borate(1-), tetrafluoro-, lead(2+) (2:1). Aggreated National Production Volume: <500,000 pounds.
Methods of Manufacturing · 2 Einträge

Reaction of lead, lead oxide, lead hydroxide, or lead carbonate with fluoroboric acid

Electrolytic dissolution

Zugehörige Reaktionen

0
Reaktionsaufzeichnung erstellen
Noch keine zugehörigen Reaktionen

Notizen zur Verbindung

Auf dieser SeiteGrundinformationenÜberblickNamen und BezeichnerEigenschaftenSicherheit und RegulatorischesChemie und IndustrieZugehörige ReaktionenNotizen zur Verbindung
EC Number
237-486-0

Lead is derived from the decay of radon. /Inorganic lead/

Divalent lead has a strong affinity for inorganic ions containing oxygen (eg, carbonate) or sulfur (sulfide). Lead can also complex with electron rich ligands in many organic cmpd such as amino acids, proteins, and humic acid.

Physikochemische Eigenschaften

Dichte
1.62 g/mL · 1.62 g/mL at 20 °C
Löslichkeit
soluble in Water
Aggregatzustand
Liquid
Farbe
Clear colorless
Wasserlöslichkeit
Soluble
InChI
1S/2BF4.Pb/c2*2-1(3,4)5;/q2*-1;+2
InChIKey
UQGXAENNKXXYNF-UHFFFAOYSA-N
SMILES
[PbH2++].F[B-](F)(F)F.F[B-](F)(F)F
CAS Datenbank
13814 · 13814-96-5(CAS DataBase Reference)
EPA chemische Informationen
Lead fluoroborate (13814-96-5)
Health Hazards · 1 Eintrag

Early symptoms of lead intoxication via inhalation or ingestion are most commonly gastrointestinal disorders, colic, constipation, etc.; weakness, which may go on to paralysis, chiefly of the extensor muscles of the wrists and less often of the ankles, is noticeable in the most serious cases. Ingestion of a large amount causes local irritation of the alimentary tract; pain, leg cramps, muscle weakness, paresthesias, depression, coma, and death may follow in 1 or 2 days. Contact with eyes or skin may cause burns and/or irritation. (USCG, 1999)

Hazards SummaryA severe skin, eye, and respiratory tract irritant; May cause fluorosis; [HSDB] See Potassium tetrafluoroborate. See Lead and linked occupational diseases.
Reactive GroupNon-Redox-Active Inorganic Compounds
Special Reports · 1 Eintrag

National Toxicology Program. Eleventh Report on Carcinogens (2005). The Report on Carcinogens is an informational scientific and public health document that identifies and discusses substances (including agents, mixtures, or exposure circumstances) that may pose a carcinogenic hazard to human health. Lead and Lead Compounds are listed as reasonably anticipated to be human carcinogens. /Lead and Lead Compounds/[Available from, as of July 31, 2009: http://ntp.niehs.nih.gov/ntp/roc/eleventh/profiles/s101lead.pdf]

RCRA Requirements · 2 Einträge

D008; A solid waste containing lead may or may not become characterized as a hazardous waste when subjected to the Toxicity Characteristic Leaching Procedure listed in 40 CFR 261.24, and if so characterized, must be managed as a hazardous waste. /Lead/

The Environmental Protection Agency is ... /promulgated/ regulations concerning ground-water monitoring with regard to screening suspected contamination at land based hazardous waste treatment, storage, and disposal facilities. ... /There are/ new requirements to analyze for a specified core list of chemicals plus those chemicals specified by the Regional Administrator on a site-specific basis. ... /Total lead (all species) is included on this list./ /Total lead (all species)/

OSHA Standards · 5 Einträge

Permissible Exposure Limit: The employer shall assure that no employee is exposed to lead at concentrations greater than 50 ug/cu m of air averaged over an 8-hr period. If an employee is exposed to lead for more than 8 hr in any work day, the permissible exposure limit, as a TWA for that day, shall be reduced according to the following formula: Maximum permissible limit (in ug/cu m)=400 divided by the number of hours worked in the day. /Lead, inorganic, as Pb/

The employer shall remove an employee from work having an exposure to lead at or above the action level on each occasion that a periodic and a follow-up blood sampling test conducted pursuant to this section indicate that the employee's blood lead level is at or above 60 ug/100 g of whole blood; and, the employer shall remove an employee from work having an exposure to lead at or above the action level on each occasion that the average of the last three blood sampling tests conducted pursuant to this section (or the average of all blood sampling tests conducted over the previous six (6) months, whichever is longer) indicates that the employee's blood lead level is at or above 50 ug/100 g of whole blood; provided, however, that an employee need not be removed if the last blood sampling test indicates a blood lead level at or below 40 ug/100 g of whole blood. ... The employer shall return an employee to his or her former job status: ... when two consecutive blood sampling tests indicate that the employee's blood lead level is at or below 40 ug/100 g of whole blood. ... The employer shall provide to an employee up to eighteen (18) months of medical removal protection benefits on each occasion that an employee is removed from exposure to lead or otherwise limited pursuant to this section. /Lead, inorganic, as Pb/

Permissible Exposure Limit: The employer shall assure that no employee is exposed to lead at concentrations greater than 50 ug/cu m of air averaged over an 8-hr period. If an employee is exposed to lead for more than 8 hr in any work day, the permissible exposure limit, as a TWA for that day, shall be reduced according to the following formula: Maximum permissible limit (in ug/cu m)=400 divided by the number of hours worked in the day. /Lead, inorganic, as Pb; Shipyard Employment/

The employer shall remove an employee from work having an exposure to lead at or above the action level on each occasion that a periodic and a follow-up blood sampling test conducted pursuant to this section indicate that the employee's blood lead level is at or above 60 ug/100 g of whole blood; and, the employer shall remove an employee from work having an exposure to lead at or above the action level on each occasion that the average of the last three blood sampling tests conducted pursuant to this section (or the average of all blood sampling tests conducted over the previous six (6) months, whichever is longer) indicates that the employee's blood lead level is at or above 50 ug/100 g of whole blood; provided, however, that an employee need not be removed if the last blood sampling test indicates a blood lead level at or below 40 ug/100 g of whole blood. ... The employer shall return an employee to his or her former job status: ... when two consecutive blood sampling tests indicate that the employee's blood lead level is at or below 40 ug/100 g of whole blood. ... The employer shall provide to an employee up to eighteen (18) months of medical removal protection benefits on each occasion that an employee is removed from exposure to lead or otherwise limited pursuant to this section. /Lead, inorganic, as Pb; Shipyard Empolyment/

For more OSHA Standards (Complete) data for LEAD FLUOROBORATE (6 total), please visit the HSDB record page.

Reactivity ProfileSolution is acidic and will corrode most metals (USCG, 1999). Toxic and irritating hydrogen fluoride gas may form in fire (USCG, 1999).
Atmospheric Standards · 2 Einträge

National primary and secondary ambient air quality standards for lead and its compounds, measured as elemental lead by a reference method based on appendix G to this part, or by an equivalent method, are: 1.5 micrograms per cubic meter, maximum arithmetic mean averaged over a calendar quarter. /Lead and its compounds, as Pb/

Listed as a hazardous air pollutant (HAP) generally known or suspected to cause serious health problems. The Clean Air Act, as amended in 1990, directs EPA to set standards requiring major sources to sharply reduce routine emissions of toxic pollutants. EPA is required to establish and phase in specific performance based standards for all air emission sources that emit one or more of the listed pollutants. Lead compounds are included on this list. /Lead compounds/

Sicherheit und Schutzausrüstung

Fire FightingExcerpt from ERG Guide 151 [Substances - Toxic (Non-Combustible)]:
First AidRemove at once all cases of lead intoxication from further exposure until the blood level is reduced to a safe value; immediately place the individual under medical care.
Exposure Control and Personal ProtectionBiological Exposure Indices (BEI) [ACGIH] - Lead in blood = 200 ug/L (20 ug/100 ml); sampling time not critical; [ACGIH]
Fire Fighting Procedures · 2 Einträge

Lead fluoborate itself does not burn. Use any agent suitable for type of surrounding fire ... Containers may explode in fire. Storage containers and parts of containers may rocket great distances, in many directions. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Notify local health and fire officials and pollution contol agencies. From a secure, explosion-proof location, use water spray to cool exposed containers. If cooling streams are ineffective (venting sound increases in volume and pitch, tank discolors or shows any signs of deforming), withdraw immediately to a secure position.

Wear positive pressure self-contained breathing apparatus when fighting fires involving this material.

Storage Conditions · 1 Eintrag

Lead fluoborate must be stored to avoid contact with oxidizers (such as perchlorates, peroxides, permanganates, chlorates, and nitrates) and chemically active metals (such as potassium, sodium, magnesium, and zinc) since violent reactions occur. A regulated, marked area should be established where this chemical is handled, used, or stored ...

Cleanup Methods · 4 Einträge

Evacuate and restrict persons not wearing protective equipment from area of spill or leak until cleanup is complete. Remove all ignition sources. Absorb liquids in vermiculite, dry sand, earth, peat, carbon, or a similar material and deposit in sealed containers. Collect powdered material in the most convenient and safe manner and deposit in sealed containers. Ventilate and wash area after clean-up is complete. It may be necessary to to contain and dispose of this chemical as a hazardous waste. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters.

Enviromental considerations-land spills: Dig a pit, pond, lagoon, or holding area to contain liquid or solid material. /SRP: If time permits, pits, ponds, lagoons, soak holes, or holding areas should be contained with a flexible impermeable membrane liner./ Cover solids with a plastic sheet to prevent dissolving in rain or fire fighting water. /Lead fluoride/

Wastewater at pH 1.3 containing 8000 ppm fluorine as Pb(BF4)2 and Sn(BF4)2 is adjusted to pH 8 with sodium hydroxide, filtered, evaporated to 1/16.

Environmental considerations: Water spill: Neutralize with agricultural lime (CaO), crushed limestone (CaCO3), or sodium bicarbonate (NaHCO3). Adjust pH to neutral (pH= 7). Use mechanical dredges or lifts to remove immobilized masses of pollutants & precipitates.

Nonfire Spill ResponseNeutralizing Agents for Acids and Caustics: Flush with water, rinse with dilute solution of sodium bicarbonate or soda ash. (USCG, 1999)
Disposal MethodsGenerators of waste (equal to or greater than 100 kg/mo) containing this contaminant, EPA hazardous waste number D008, must conform with USEPA regulations in storage, transportation, treatment and disposal of waste. /Lead/
Preventive Measures · 5 Einträge

Avoid breathing dusts, and fumes from burning material. Keep upwind. Avoid bodily contact with material.

If material not involved in fire: Keep material out of water sources & sewers. Build dikes to contain flow as necessary.

SRP: Local exhaust ventilation should be applied wherever there is an incidence of point source emissions or dispersion of regulated contaminants in the work area. Ventilation control of the contaminant as close to its point of generation is both the most economical and safest method to minimize personnel exposure to airborne contaminants.

SRP: The scientific literature for the use of contact lenses in industry is conflicting. The benefit or detrimental effects of wearing contact lenses depend not only upon the substance, but also on factors including the form of the substance, characteristics and duration of the exposure, the uses of other eye protection equipment, and the hygiene of the lenses. However, there may be individual substances whose irritating or corrosive properties are such that the wearing of contact lenses would be harmful to the eye. In those specific cases, contact lenses should not be worn. In any event, the usual eye protection equipment should be worn even when contact lenses are in place.

For more Preventive Measures (Complete) data for LEAD FLUOROBORATE (9 total), please visit the HSDB record page.

Isolation and EvacuationExcerpt from ERG Guide 151 [Substances - Toxic (Non-Combustible)]:
Minimum Risk LevelChronic Inhalation: 0.05 mg/m3 (L134)
Threshold Limit Values (TLV) · 5 Einträge

0.05 [mg/m3], as Pb

8 hr Time Weighted Avg (TWA): 0.05 mg/cu m. /Lead, and inorganic compounds, as Pb/

Excursion Limit Recommendation: Excursions in worker exposure levels may exceed three times the TLV-TWA for no more than a total of 30 min during a work day, and under no circumstances should they exceed five times the TLV-TWA, provided that the TLV-TWA is not exceeded. /Lead, inorganic compounds, as Pb/

A3; Confirmed animal carcinogen with unknown relevance to humans.

Biological Exposure Index (BEI): Determinant: lead in blood; Sampling Time: not critical; BEI: 30 ug/100 mL. [Note: Women of child bearing potential, whose blood Pb exceeds 10 ug/dL, are at risk of delivering a child with a blood Pb over the current Centers for Disease Control guideline of 10 ug/dL. If the blood Pb of such children remains elevated, they may be at increased risk of cognitive deficits. The blood Pb of these children should be closely monitored and appropriate steps should be taken to minimize the child's exposure to environmental lead.] /Lead, and inorganic compounds, as Pb/

Toxikologische Informationen

TreatmentLead poisoning is usually treated with chelation therapy using DMSA, EDTA, or dimercaprol. (L21)
Health Effects · 1 Eintrag

Lead is a neurotoxin and has been known to cause brain damage and reduced cognitive capacity, especially in children. Lead exposure can result in nephropathy, as well as blood disorders such as high blood pressure and anemia. Lead also exhibits reproductive toxicity and can results in miscarriages and reduced sperm production. (L21)

Adverse EffectsNeurotoxin - Predominantly motor
Exposure RoutesOral (L136) ; inhalation (L136); dermal (L136)
Toxicity Summary · 1 Eintrag

Lead mimics other biologically important metals, such as zinc, calcium, and iron, competing as cofactors for many of their respective enzymatic reactions. For example, lead has been shown to competitively inhibit calcium's binding of calmodulin, interferring with neurotransmitter release. It exhibits similar competitive inhibition at the NMDA receptor and protein kinase C, which impairs brain microvascular formation and function, as well as alters the blood-brain barrier. Lead also affects the nervous system by impairing regulation of dopamine synthesis and blocking evoked release of acetylcholine. However, it's main mechanism of action occurs by inhibiting delta-aminolevulinic acid dehydratase, an enzyme vital in the biosynthesis of heme, which is a necesssary cofactor of hemoglobin. (T4, A20, A22, L136)

Signs and Symptoms · 1 Eintrag

Symptions of chronic lead poisoning include reduced cognitive abilities, nausea, abdominal pain, irritability, insomnia, metal taste in the mouth, excess lethargy or hyperactivity, chest pain, headache and, in extreme cases, seizures, comas, and death. There are also associated gastrointestinal problems, such as constipation, diarrhea, vomiting, poor appetite, weight loss, which are common in acute poisoning. (A2, L21)

Human Toxicity Excerpts · 5 Einträge

/SIGNS AND SYMPTOMS/ Lead fluoborate can affect you when breathed in and if swallowed from food, drinks, or cigarettes. Contact can cause skin and eye irritation and burns. Irritates the respiratory tract. Can cause headache, irritability, mood changes, reduced memory, and disturbed sleep.

/SIGNS AND SYMPTOMS/ Acute effects: inhalation-extreme irritation of respiratory tract ... Ingestion-necrosis of esophagus and stomach with nausea, vomiting, diarrhea, circulatory collapse, death. /Aqueous/

/SIGNS AND SYMPTOMS/ Acute effects: external contact: liq or vapor causes severe irritation of eyes and eyelids which may result in prolonged or permanent visual defects or total destruction of eyes. Skin contact may result in severe burns.

/SIGNS AND SYMPTOMS/ Chronic effects: (from inhalation or ingestion), may cause fluorosis. Symptoms: wt loss, malaise, anemia, leukopenia, discoloration of teeth, osteosclerosis.

/SIGNS AND SYMPTOMS/ Contact of skin with anhyd liq produces severe burns that are felt immediately. Concentrated aq soln also cause early sensation of pain, but dilute soln may give no warning of injury.

Carcinogen Classification2A, probably carcinogenic to humans. (L135)
Evidence for Carcinogenicity · 2 Einträge

A3; Confirmed animal carcinogen with unknown relevance to humans.

Lead, lead compounds: Reasonably anticipated to be a human carcinogen

Probable Routes of Human Exposure · 2 Einträge

NIOSH (NOES Survey 1981-1983) has statistically estimated that 6369 workers (1307 of these were female) were potentially exposed to lead fluoroborate in the US(1).

Ceramic artists can be exposed to many hazardous materials, generally related to dry clays, glazes and kiln use. Glazes can contain lead, antimony, arsenic, barium, beryllium, boron, chromium, cobalt, cadmium, copper, vanadium and other materials which all have potential toxic effects.

Antidote and Emergency Treatment · 5 Einträge

Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Lead and related compounds/

Basic treatment: Establish a patent airway (oropharyngeal or nasopharyngeal airway, if needed). Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for shock and treat if necessary ... . Anticipate seizures and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with 0.9% saline (NS) during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool ... . Administer activated charcoal ... . /Lead and related compounds/

Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious or is in severe respiratory distress. Moderate hyperventilation (20 respiration per minute) may be beneficial for increased intracranial pressure. Start IV administration of 0.9% saline (NS) or lactated Ringer's (LR) /SRP: "To keep open", minimal flow rate/. For hypotension ... . Treat seizures with diazepam or lorazepam ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Lead and related compounds/

Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Boron and Related Compounds/

For more Antidote and Emergency Treatment (Complete) data for LEAD FLUOROBORATE (9 total), please visit the HSDB record page.

Acceptable Daily Intakes · 2 Einträge

Tolerable intake of lead for preschool children should be less than the 3 mg/wk recommended provisionally for adults. ... /Inorganic lead/

0.007 mg/kg (WHO) /Lead; from table/

Regulatorische Informationen

RCRA Requirements · 2 Einträge

D008; A solid waste containing lead may or may not become characterized as a hazardous waste when subjected to the Toxicity Characteristic Leaching Procedure listed in 40 CFR 261.24, and if so characterized, must be managed as a hazardous waste. /Lead/

The Environmental Protection Agency is ... /promulgated/ regulations concerning ground-water monitoring with regard to screening suspected contamination at land based hazardous waste treatment, storage, and disposal facilities. ... /There are/ new requirements to analyze for a specified core list of chemicals plus those chemicals specified by the Regional Administrator on a site-specific basis. ... /Total lead (all species) is included on this list./ /Total lead (all species)/

Atmospheric Standards · 2 Einträge

National primary and secondary ambient air quality standards for lead and its compounds, measured as elemental lead by a reference method based on appendix G to this part, or by an equivalent method, are: 1.5 micrograms per cubic meter, maximum arithmetic mean averaged over a calendar quarter. /Lead and its compounds, as Pb/

Listed as a hazardous air pollutant (HAP) generally known or suspected to cause serious health problems. The Clean Air Act, as amended in 1990, directs EPA to set standards requiring major sources to sharply reduce routine emissions of toxic pollutants. EPA is required to establish and phase in specific performance based standards for all air emission sources that emit one or more of the listed pollutants. Lead compounds are included on this list. /Lead compounds/

CERCLA Reportable Quantities · 1 Eintrag

Persons in charge of vessels or facilities are required to notify the National Response Center (NRC) immediately, when there is a release of this designated hazardous substance, in an amount equal to or greater than its reportable quantity of 10 lb or 4.54 kg. The toll free number of the NRC is (800) 424-8802. The rule for determining when notification is required is stated in 40 CFR 302.4 (section IV. D.3.b).

Clean Water Act Requirements · 2 Einträge

Lead fluoroborate is designated as a hazardous substance under section 311(b)(2)(A) of the Federal Water Pollution Control Act and further regulated by the Clean Water Act Amendments of 1977 and 1978. These regulations apply to discharges of this substance. This designation includes any isomers and hydrates, as well as any solutions and mixtures containing this substance.

Toxic pollutant designated pursuant to section 307(a)(1) of the Federal Water Pollution Control Act and is subject to effluent limitations. /Lead and compounds/

State Drinking Water Standards(AZ) ARIZONA 50 ug/L /Lead/
State Drinking Water Guidelines · 2 Einträge

(AZ) ARIZONA 20 ug/L /Lead/

(ME) MAINE 10 ug/L /Lead/

Federal Drinking Water StandardsEPA 15 ug/L (Action Level) /Lead/

Sicherheitsdaten

wgk
3
tsca
TSCA listed
ridadr
UN 2922 8/PG 2
hs_code
28269090
RTECS-Nr.
ED2700000
risk_code
61-20/22-33-50/53-62
Toxizität
rat,LDLo,oral,50mg/kg (50mg/kg),Kodak Company Reports. Vol. 21MAY1971,
hazard_code
T,N
safety_code
53-45-60-61-36/37
hazard_class
6.1
packing_group
III
Speicherklasse
6.1C - Combustible acute toxic Cat.3toxic compounds or compounds which causing chronic effects
Giftige Stoffe Daten
13814-96-5(Hazardous Substances Data)
Hazard Classifications
Acute Tox. 4 InhalationAcute Tox. 4 OralAquatic Acute 1Aquatic Chronic 1Repr. 1ASTOT RE 2
Formulations/Preparations · 2 Einträge

Grades of purity: 50-62% solutions in water

51% solution

General Manufacturing Information · 2 Einträge

Borate(1-), tetrafluoro-, lead(2+) (2:1): ACTIVE

The commercial lead fluoroborate solution is 28.9% lead and has a density of 1.75 g/cu cm.

Anwendungen · 1 Eintrag

VerwendenUsed in tin-lead electroplatingLead(II) tetrafluoroborate is used as a catalyst involved in calixarene formation through hydrogen-bonded dimmers and in the preparation of linear polyesters. It is involved in the development and optimization of a bipolar lead-boron tetrafluoride accumulator. It is an electroplating solution for coating metal objects with lead and curing agent for epoxy resins. Further, it is used in printing lines, tin-lead alloy plating, lead soldering and also as a circuit board tin-lead alloy plating.

Vor- und nachgelagerte Produkte

Vorgelagerte Rohstoffe

BleimonoxidBleicarbonatFluoroboric acidAluminiumoxid