HuagongsheHuagongshe Chemie-Druckbericht · Nur für Forschungszwecke
HCID 17721Erstellt: 3. November 2026
Di-tert-butyl-α,α,α',α'-tetramethyl-(p-phenylendimethylen)diperoxid
Hodgsons Luperco 802-PP-10 · Hodgsons Luperco 802-PP-40 · 1,4-Di-(tert.-butylperoxyisopropyl)-benzol · 1,4-bis(2-tert-butylperoxypropan-2-yl)benzene · 1,4-bis(alpha-(t-butyldioxy)isopropyl)benzene · 1,4-bis(alpha-(tert-butyldioxy)isopropyl)benzene · alpha,alpha'-bis(tert-butyldioxy)-p-diisopropylbenzene · 1,4-Bis (tert butylperoxyisopropyl) benzene (peroxide F40)
https://huagongshe.com/de/chemical/17721
Identifikatoren & physikalische Daten
| CAS No. | 25155-25-3 |
|---|
| Summenformel | C20H34O4 |
|---|
| Durchschnittliche Molmasse | 338,5 g/mol |
|---|
| Monoisotopische Masse | 338,24570956 g/mol |
|---|
| SMILES | CC(C)(C)OOC(C)(C)c1ccc(C(C)(C)OOC(C)(C)C)cc1 |
|---|
| InChIKey | GWQOYRSARAWVTC-UHFFFAOYSA-N |
|---|
| PubChem CID | 17721 |
|---|
| ChEMBL | CHEMBL3185297 |
|---|
| EC No. | 220-479-1 |
|---|
| DTXSID | DTXSID60881110 |
|---|
| Lokaler Name | Di-tert-butyl-α,α,α',α'-tetramethyl-(p-phenylendimethylen)diperoxid |
|---|
Chemische & physikalische Eigenschaften
| XLogP | 4,5 |
|---|
| Polarare Oberfläche (TPSA) | 36,9 |
|---|
| H-Brücken-Donoren | 0 |
|---|
| H-Brücken-Akzeptoren | 4 |
|---|
| Frei drehbare Bindungen | 8 |
|---|
| Schwere Atome | 24 |
|---|
| Formalladung | 0 |
|---|
| Komplexität | 341 |
|---|
| Stoffklassen | Other Classes -> Peroxides, Organic |
|---|
| SpringerMaterials Properties | Boiling point |
|---|
| Schmelzpunkt | 79 °C |
|---|
| Dampfdruck | 0.0000171 [mmHg]0.01Pa at 50℃ |
|---|
| Siedepunkt | 434.61°C (rough estimate) |
|---|
| Dichte | 1.0256 (rough estimate) |
|---|
| Brechungsindex | 1.6000 (estimate) |
|---|
| Löslichkeit | 40μg/L at 20℃ |
|---|
| Henry-Konstante | 1.0×10-1 mol/(m3Pa) at 25℃, Zhang et al. (2010) |
|---|
| LogP (Verteilungskoeffizient) | 7.3 at 20℃ |
|---|
| EPA chemische Informationen | Peroxide, [1,4-phenylenebis(1-methylethylidene)]bis[(1,1-dimethylethyl) (2781-00-2) |
|---|
Sicherheit & Vorschriften
| GHS-Einstufung | DangerH242 (100%): Heating may cause a fire [Danger Self-reactive substances and mixturesOrganic peroxides]P210, P234, P235, P240, P273, P280, P370+P378, P403, P410, P411, P420, and P501 (click each P-code to see the statement)The GHS information provided by 1 company from 1 notification to the ECHA C&L Inventory. |
|---|
| Regulatorische Informationen | Chemical: Peroxide, [1,4-phenylenebis(1-methylethylidene)]bis[(1,1-dimethylethyl)Hazard Traits - BioaccumulationEnvironmental PersistenceREACH registered substance: Di-tert-butyl α,α,α',α'-tetramethyl-(p-phenylenedimethylene) diperoxide (EC: 220-479-1)Peroxide, [1,3(or 1,4)-phenylenebis(1-methylethylidene)]bis[(1,1-dimethylethyl): Does not have an individual approval but may be used under an appropriate group standard |
|---|
| Gefahrenübersicht | Emergency treatment: Irritants[HSDB] |
|---|
| Hazard Classes and Categories | Org. Perox. D (100%) |
|---|
| Brandbekämpfungsverfahren | In case of fire, water should be applied by the sprinkler system or by hose from a safe distance, preferably with a fog nozzle. Foam may be necessary instead if the peroxide is diluted in a low density flammable solvent. Portable extinguishers should not be used except for very small fires. Peroxides threatened by fire should be wetted from a safe distance for cooling. /Peroxides, Organic and Inorganic/ |
|---|
| Reinigungsverfahren | Spills should be cleaned up promptly using non-sparking tools and an inert, moist diluent such as vermiculite or sand. Sweepings may be placed in open containers or polyethylene bags and the area washed with water and detergent. Spilled, contaminated, waste or questionable peroxides should be destroyed. /Peroxides, Organic and Inorganic/Most peroxides can be hydrolyzed by adding them slowly with stirring to about ten times their weight of cold 10% sodium hydroxide solution. The reaction may require several hours. /Peroxides, Organic and Inorganic/Dilute and drain into the sewer with abundant water. /Hydrogen peroxide/ |
|---|
| Entsorgungsverfahren | SRP: At the time of review, criteria for land treatment or burial (sanitary landfill) disposal practices are subject to significant revision. Prior to implementing land disposal of waste residue (including waste sludge), consult with environmental regulatory agencies for guidance on acceptable disposal practices. |
|---|