Silicon tetrafluoride
7783-61-1F[Si](F)(F)FABTOQLMXBSRXSM-UHFFFAOYSA-NSilicon tetrafluoride appears as a colorless, nonflammable, corrosive and toxic gas with a pungent odor similar to that of hydrochloric acid. Very toxic by inhalation. Vapor is heavier than air. Under prolonged exposure to heat the containers may rupture violently and rocket.
7783-61-1DTXSID0064830Toxic Gases & Vapors -> Corrosive Gases
Corrosives
VERY PUNGENT ODOR SIMILAR TO THAT OF HYDROGEN CHLORIDE
Suffocating odor
0.00469 g/cu-cm (STP); 1.598 g/cu-cm (liquid at -80 °C); 2.145 g/cu-cm (solid at -195 °C)
DENSITY: 4.69 G/L @ 760 MM HG
SOL IN ABSOLUTE ALCOHOL; SOL IN HYDROGEN FLUORIDE; INSOL IN ETHER
Solubility in water: reaction
Sicherheitsangaben dienen nur zur Orientierung und ersetzen weder das Sicherheitsdatenblatt (SDB) des Lieferanten noch geltende Vorschriften oder eine fachliche Bewertung.
Danger
H280 (58.6%): Contains gas under pressure; may explode if heated [Warning Gases under pressure]
P260, P261, P262, P264, P270, P271, P280, P284, P301+P316, P301+P330+P331, P302+P352, P302+P361+P354, P304+P340, P305+P354+P338, P316, P320, P321, P330, P361+P364, P363, P403+P233, P405, P410+P403, and P501 (click each P-code to see the statement)
Aggregated GHS information provided per 157 reports by companies from 8 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.
Not Classified
Chemical: Silane, tetrafluoro-
Silane, tetrafluoro- is listed on the EPA's Chemical Data Reporting (CDR) system. Manufacturers and importers of Silane, tetrafluoro- are required to report information about their production and use of this chemical to the EPA under the Toxic Substances Control Act (TSCA). (40 eCFR Part 711)
REACH registered substance: Silicon tetrafluoride (EC: 232-015-5)
Silane, tetrafluoro-: HSNO Approval: HSR001067 Approved with controls
The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:
· Some may burn but none ignite readily.
Not combustible. Gives off irritating or toxic fumes (or gases) in a fire.
Used to manufacture silane, silicon for electronics, and fluosilicic acid; Used as a sealant in oil well drilling; [HSDB]
Petroleum Production and Refining [Category: Industry]
MANUFACTURE OF FLUOSILICIC ACID; TO SEAL WATER OUT OF OIL WELLS DURING DRILLINGS; INTERMEDIATE IN MANUFACTURE OF PURE SILICON
Has been used in the manufacture of silane and of photovoltaic or electronic silicon.
COMMERCIAL PREPN FROM WASTE GASES OF PHOSPHATE FERTILIZER PRODN.
ACTION OF HYDROGEN FLUORIDE OR CONCENTRATED SULFURIC ACID & A METALLIC FLUORIDE ON SILICA OR SILICATES.
Silicon & boron burn in fluorine forming SiF4 & BF3, respectively
GRADE: PURE, 99.5% MINIMUM
/Available as/ semiconductor grade, 99.6%; 99.99% min purity grade
Industrial Gas Manufacturing
Silane, tetrafluoro-: ACTIVE
Union Carbide (Matheson Department) is one of the oldest producers. New facilities producing under 100 t/a have been announced by Allied Chemical Company (USA).
Manufacture of fluosilicic acid, intermediate in manufacture of pure silicon, to seal water out of oil wells during drilling.
-90.2 °C (UNDER PRESSURE)
-77 °C
3.57 (gas, air = 1) @ 15 °C
Relative vapor density (air = 1): 3.6
Silicon tetrafluoride appears as a colorless, nonflammable, corrosive and toxic gas with a pungent odor similar to that of hydrochloric acid. Very toxic by inhalation. Vapor is heavier than air. Under prolonged exposure to heat the containers may rupture violently and rocket.
CBI
Colorless gas with a pungent odor; [HSDB]
COLOURLESS GAS WITH PUNGENT ODOUR.
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:
· TOXIC and/or CORROSIVE; may be fatal if inhaled, ingested or absorbed through skin.
On contact with water, may hydrolyze to form fluosilicic acid and silicon dioxide. May be corrosive to the skin, eyes, and respiratory tract; Inhalation may cause pulmonary edema; Chronic exposure may cause fluorosis; [CHEMINFO MSDS] See Fluorosilic acid. See FLUORIDES.
When heated to decomposition SILICON TETRAFLUORIDE emits toxic fluoride fumes [Lewis, 3rd ed., 1993, p. 1138]. Reacts violently with alcohols to form HF. Attacks many metals in the presence of moisture. Reacts violently to explosively with lithium nitride [Porritt, L. J., Chem. Brit., 1979, 15, p. 282]. Mixtures with sodium are shock-sensitive explosives [Leleu, Cahiers, 1975, (79), p. 270].
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:
NO water. In case of fire in the surroundings, use appropriate extinguishing media. In case of fire: keep cylinder cool by spraying with water. NO direct contact with water.
Fresh air, rest. Half-upright position. Refer for medical attention.
Rinse skin with plenty of water or shower. Refer for medical attention .
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
· Do not touch or walk through spilled material.
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:
General First Aid:
· Wear positive pressure self-contained breathing apparatus (SCBA).
Biological Exposure Indices (BEI) [ACGIH] - Fluorides in urine = 2 mg/L prior to shift or 3 mg/L at end of shift; (Repeated measurements recommended.)
1.0 [mg/m3], as F, inhalable fraction[German Research Foundation (DFG)]
If material involved in fire: Extinguish fire using agent suitable for type of surrounding fire. (Material itself does not burn or burns with difficulty.) Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible. Do not use water on material itself. Use water spray to knock-down vapors.
SILICON TETRAFLUORIDE REMOVAL FROM WASTE GASES BY AQ SCRUBBING.
TRAPPING OF OFFGAS SILICON TETRAFLUORIDE FROM MFR OF FERTILIZERS BY HIGH-SPEED PLATE APPARATUS.
SRP: At the time of review, criteria for land treatment or burial (sanitary landfill) disposal practices are subject to significant revision. Prior to implementing land disposal of waste residue (including waste sludge), consult with environmental regulatory agencies for guidance on acceptable disposal practices.
/For laboratory quantities/ Chemical treatment: Transfer into an evaporating dish containing sodium bicarbonate, spray with ammonia (6 M NH4OH) /6 M-ammonium hydroxide/ while stirring and then spread with crushed ice. Continue spraying with ammonia until the smoke of ammonium chloride partly subsides and add iced water while stirring. Neutralize and slowly transfer the mixture into a drain with running water.
Sore throat. Cough. Burning sensation. Shortness of breath. Laboured breathing. Symptoms may be delayed.
Redness. ON CONTACT WITH LIQUID: FROSTBITE.
Redness.
All silicon tetrahalides are highly toxic by inhalation and ingestion, and extremely irritation to skin and mucous membranes owing to their corrosive nature resulting from hydrolysis in moist tissue to liberate halogen acid. /Silicon Halides/
TOXIC BY INHALATION. STRONG IRRITANT TO MUCOUS MEMBRANES.
Silicon tetrafluoride
15
45
Weapons of Mass Effect chemical material that, if stolen or diverted, can be converted into weapons using simple chemistry, equipment, or techniques.
synthetischeSilicon tetrafluoride is prepared by heating silica with dilute hydrofluoric acid at high temperatures:SiO2 + 4HF → SiF4 + 2H2OAlso, the tetrafluoride may be obtained by heating the elements:Si + 2F2 → SiF4.