Zurück
HuagongsheHuagongshe Chemie-Druckbericht · Nur für Forschungszwecke
HCID 9633Erstellt: 26. Oktober 2026

Pentafluorethan

r125 · HFC-125 · 1,1,1,2,2-Pentafluoroethane · C2F5H · HCFC-125 · f125 · R-125 · CFC125

https://huagongshe.com/de/chemical/9633

Molekülstruktur von Pentafluorethan

Identifikatoren & physikalische Daten

CAS No.354-33-6
SummenformelC2HF5
Durchschnittliche Molmasse120,02 g/mol
Monoisotopische Masse119,99984113 g/mol
SMILESFC(F)C(F)(F)F
InChIKeyGTLACDSXYULKMZ-UHFFFAOYSA-N
PubChem CID9633
EC No.206-557-8
DTXSIDDTXSID1024251
Lokaler NamePentafluorethan

Chemische & physikalische Eigenschaften

XLogP2,2
Polarare Oberfläche (TPSA)0
H-Brücken-Donoren0
H-Brücken-Akzeptoren5
Frei drehbare Bindungen0
Schwere Atome7
Formalladung0
Komplexität51,6
PFASPFAS -> PFAS with analytical method availablePFAS -> Intentionally added food contact chemicalsPFAS -> Other NonpolymersPFAS -> Other/unspecifiedPFAS -> PFAS identified in REACH Regulation EC No. 1272/2008PFAS -> non-polymer
SolventsSolvents -> Chlorofluorocarbons
SpringerMaterials PropertiesSchoenflies notation
PestizidePesticide -> EPA IRIS
DichteLiquid density = 1.23 g/cu cm at 20 °C1,248 g/cm3
Flame RetardantsFlame retardants -> Flame retardants and extinguishing agents
Color/FormColorless gas
Siedepunkt-48.1 °C-48.5°C
DecompositionWhen heated to decomposition it emits toxic vapors of /flouride/.All fluorocarbons will undergo thermal decomposition when exposed to flame or red-hot metal. /Fluorocarbons/
Schmelzpunkt-100.6 °C-103°C
Dampfdruck9501 mm Hg at 25 °C1375.8kPa at 25℃
BrechungsindexLiquid refractive index = 1.5012 at 19 °C/D
Löslichkeit430mg/L at 25℃
Henry-Konstante3.1×10-4 mol/(m3Pa) at 25℃, Miguel et al. (2000)
StabilitätStable.
LogP (Verteilungskoeffizient)1.48 at 20℃
CAS Datenbank354-33-6(CAS DataBase Reference)
NIST chemische InformationenFc-125(354-33-6)
EPA chemische InformationenHFC-125 (354-33-6)
ECETOC JACC REPORTPentafluoroethane (354-33-6)

Sicherheit & Vorschriften

GHS-EinstufungWarningH280 (100%): Contains gas under pressuremay explode if heated [Warning Gases under pressure]P410+P403</a, and a href="https://pubchem.ncbi.nlm.nih.gov/ghs/#P410+P403">P410+P403 (click each P-code to see the statement)Aggregated GHS information provided per 205 reports by companies from 4 notifications to the ECHA C&L Inventory.H280: Contains gas under pressure
Regulatorische InformationenChemical: Ethane, 1,1,1,2,2-pentafluoro-Ethane, 1,1,1,2,2-pentafluoro- is listed on the EPA's Chemical Data Reporting (CDR) system. Manufacturers and importers of Ethane, 1,1,1,2,2-pentafluoro- are required to report information about their production and use of this chemical to the EPA under the Toxic Substances Control Act (TSCA). (40 eCFR Part 711)PMN - indicates a commenced PMN (Pre-Manufacture Notices) substance.Status: Active Update: 14-12-2022 https://echa.europa.eu/registration-dossier/-/registered-dossier/15415Pentafluoroethane: Does not have an individual approval but may be used as a component in a product covered by a group standard. It is not approved for use as a chemical in its own right.
Weitere SicherheitsinformationenIMAP assessments - Ethane, pentafluoro-: Environment tier II assessment
DOT-KennzeichnungNon-Flammable Gas
BrandgefahrenExcerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:· Some may burn but none ignite readily.
GesundheitsgefahrenExcerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:· Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas.
GefahrenübersichtEvaporating liquid can cause frostbiteA simple asphyxiant[CAMEO] Evaporating liquid can cause frostbiteIn confined space spill, may displace air and act as simple asphyxiant[MSDSonline]
DOT-Nummer und Handbuch3220 126
Reaktive GruppeFluorinated Organic Compounds
Special ReportsDanish EPASurvey of selected fluorinated green-house gases (2015)[Available from, as of March 3, 2016: http://eng.mst.dk/]Zakhari S, Aviado DMCardiovascular Toxicology of Aerosol Propellants, Refrigerants and Related SolventsTarget Organ Toxicology Series: Cardiovascular Toxicology, XII+ 388 pagesRaven Press: New York, NY 281-326 (1982). Review of the toxicology of aerosol propellants, refrigerants and related solvents on the cardiovascular system of humans.
TSCA-AnforderungenPursuant to section 8(d) of TSCA, EPA promulgated a model Health and Safety Data Reporting Rule. The section 8(d) model rule requires manufacturers, importers, and processors of listed chemical substances and mixtures to submit to EPA copies and lists of unpublished health and safety studies. Ethane, pentafluoro- is included on this list. Effective date: 10/15/90Sunset date: 11/9/93.
Reactivity ProfilePENTAFLUOROETHANE may be incompatible with strong oxidizing and reducing agents. May be incompatible with many amines, nitrides, azo/diazo compounds, alkali metals, and epoxides.
DOT Emergency Guidelines/GUIDE 126 GASES - COMPRESSED or LIQUEFIED (Including Refrigerant Gases)/ Fire or Explosion: Some may burn but none ignite readily. Containers may explode when heated. Ruptured cylinders may rocket./GUIDE 126 GASES - COMPRESSED or LIQUEFIED (Including Refrigerant Gases)/ Health: Vapors may cause dizziness or asphyxiation without warning. Vapors from liquefied gas are initially heavier than air and spread along ground. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. Fire may produce irritating, corrosive and/or toxic gases./GUIDE 126 GASES - COMPRESSED or LIQUEFIED (Including Refrigerant Gases)/ Public Safety: CALL Emergency Response Telephone Number on Shipping Paper first. If Shipping Paper not available or no answer, refer to appropriate telephone number listed on the inside back cover. As an immediate precautionary measure, isolate spill or leak area for at least 100 meters (330 feet) in all directions. Keep unauthorized personnel away. Stay upwind. Many gases are heavier than air and will spread along ground and collect in low or confined areas (sewers, basements, tanks). Keep out of low areas. Ventilate closed spaces before entering./GUIDE 126 GASES - COMPRESSED or LIQUEFIED (Including Refrigerant Gases)/ Protective Clothing: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing will only provide limited protection.For more DOT Emergency Guidelines (Complete) data for PENTAFLUOROETHANE (8 total), please visit the HSDB record page.
BrandbekämpfungExcerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:
Freisetungsmaßnahmen· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.· Do not touch or walk through spilled material.
Erste HilfeExcerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:General First Aid:
Expositionsschutz und Persönliche Schutzausrüstung· Wear positive pressure self-contained breathing apparatus (SCBA).
Freisetung ohne BrandExcerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:
EntsorgungsverfahrenSRP: Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air qualitypotential migration in air, soil or watereffects on animal, aquatic and plant lifeand conformance with environmental and public health regulations. If it is possible or reasonable use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination.
Isolation and EvacuationExcerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:Immediate precautionary measure
Personal Protective Equipment (PPE)Excerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:
Emergency Response Planning Guidelines· Use extinguishing agent suitable for type of surrounding fire.
Other Standards Regulations and GuidelinesGlobal Warming Potential (GWP): Chemical: HFC-125GWP: 3,500 (100-Year Time Horizon)Workplace Environmental Exposure Level (WEEL): 8-hr Time-weighted Average (TWA) 1000 ppm. Last Revised: 2009.
UmweltverhaltenTERRESTRIAL FATE: Based on a classification scheme(1), an estimated Koc value of 140(SRC), determined from a structure estimation method(2), indicates that pentafluoroethane is expected to have high mobility in soil(SRC). Volatilization of pentafluoroethane from moist soil surfaces is expected to be an important fate process(SRC) given an estimated Henry's Law constant of 0.049 atm-cu m/mole(SRC), using a fragment constant estimation method(2). Pentafluoroethane is expected to volatilize from dry soil surfaces(SRC) based upon a vapor pressure of 9501 mm Hg at 25 °C(3). Pentafluoroethane may biodegrade slowly under aerobic conditions(4), but is not expected to biodegrade under anaerobic conditions(5).AQUATIC FATE: Based on a classification scheme(1), an estimated Koc value of 140(SRC), determined from a structure estimation method(2), indicates that pentafluoroethane is expected to adsorb to suspended solids and sediment(SRC). Volatilization from water surfaces is expected(3) based upon an estimated Henry's Law constant of 0.049 atm-cu m/mole(SRC), developed using a fragment constant estimation method(2). Using this Henry's Law constant and an estimation method(3), volatilization half-lives for a model river and model lake are 3.2 hours and 4.3 days, respectively(SRC). Pentafluoroethane is not expected to undergo hydrolysis in the environment based on estimated hydrolysis half-lives of 3.2 years and 120 days at pH values of 7 and 8, respectively(2). According to a classification scheme(4), an estimated BCF of 5(SRC), from an estimated log Kow of 1.55(2) and a regression-derived equation(2), suggests the potential for bioconcentration in aquatic organisms is low(SRC). Pentafluoroethane may biodegrade slowly under aerobic conditions(5), but is not expected to biodegrade under anaerobic conditions(6).ATMOSPHERIC FATE: According to a model of gas/particle partitioning of semivolatile organic compounds in the atmosphere(1), pentafluoroethane, which has a vapor pressure of 9501 mm Hg at 25 °C(2), is expected to exist solely as a gas in the ambient atmosphere. Gas-phase pentafluoroethane is degraded in the atmosphere by reaction with photochemically-produced hydroxyl radicals(SRC)the half-life for this reaction in air is estimated to be 23 years(SRC), calculated from its rate constant of 1.9X10-15 cu cm/molecule-sec at 25 °C(3). Pentafluoroethane does not contain chromophores that absorb at wavelengths >290 nm(4) and, therefore, is not expected to be susceptible to direct photolysis by sunlight(SRC). Pentafluoroethane has an atmospheric life-time of 26-36.5 years(5-10). Pentafluoroethane has estimated 20, 100 and 500 year Global Warming Potentials of 4600-5738, 2800-3800 and 920-1100, respectively(6-10).
Unerwünschte WirkungenNeurotoxin - Acute solvent syndrome
ToxizitätsübersichtIDENTIFICATION AND USE: Pentafluoroethane (HFC-125) is a colorless gas. More than 99% of HFC-125 produced worldwide used as a blend component for commercial refrigeration and air conditioning systems. The use as a fire-extinguishing agent in total flooding systems is another application of HFC-125. Minor applications include the use of HFC-125 in plastic foam blowing and as a solvent in special applications. HUMAN EXPOSURE AND TOXICITY: A chromosomal aberration test was carried out in human lymphocytes exposed up to 700,000 ppm (3,436,000 mg/cu m) HFC-125 for 3, 24 and 48 hours, with and without metabolic activation. This study gave clearly negative results. ANIMAL STUDIES: Rats (males and females) were exposed to 800,000 ppm (3,927,000 mg/cu m) HFC-125 in atmosphere for 4 hours. No mortality was observed within 14 days after the exposure. During the exposure, clinical signs typical of an anesthetic effect, such as abnormal respiration and ataxic gait, were observed. These effects disappeared within 1 hour after the end of the exposure period. Cardiac sensitization potential of HFC-125 following adrenaline injection was studied in beagle dogs. Two dogs exposed respectively to 200,000 and 300,000 ppm HFC-125 showed fatal ventricular fibrillation. In 13-week study, groups of male and female rats were exposed to 0, 5,000, 15,000 and 50,000 ppm (0, 24.544, 73,632 and 245,440 mg/cu m) HFC-125 (6 hrs/day, 5 days/week). Additional groups of male and female rats were designated for a 4-week recovery period. No mortality was found at any dose. Pregnant female rabbits were exposed to levels of 0, 5,000, 15,000 or 50,000 ppm (0, 24.544, 73,632 and 245,440 mg/cu m) for 6 hrs/day during the gestation days 6-18 and sacrificed on day 29 of gestation. There was no evidence of any treatment-related morphological change or of increased incidence of visceral and skeletal anomalies or variants. Pregnant female rats were exposed to levels of 0, 5,000, 15,000 or 50,000 ppm (0, 24.544, 73,632 and 245,440 mg/cu m) for 6 hrs/day during the gestation days 6-15 and sacrificed on day 20 of gestation. No statistically-significant differences in the incidence of anomalies and variants were observed during visceral and skeletal examination of fetuses among the control and the treated groups. An erythrocyte micronucleus test was performed in mice. No significant changes were observed in the ratio of polychromated to mature cells among the control group and the groups treated with HFC-125. A cytogenetic assay for the study of chromosomal aberrations was carried out in Chinese hamster ovary cells exposed to concentrations up to 700,000 ppm (3,436,000 mg/cu m) for 4 hours and up to 600,000 ppm (2,945,000 mg/cu m) for 24 and 48 hours, with and without metabolic activation. Positive results were observed only after 48 hours of exposure to 600,000 ppm HFC-125 in the absence of metabolic activation. However, the increased incidence of chromosomal aberration, observed under this experimental condition was concurrent with clear evidence of cytotoxicity. HFC-125 up to 200,000 ppm (982,000 mg/cu m) was tested in 2 strains of Salmonella typhimurium, with and without metabolic activation. Negative results were obtained with both strains.
Effluent ConcentrationsPentafluoroethane was detected in the emissions of hydrofluorocarbon packaging in The Netherlands in 1990 at a rate of 56 metric kilo tons CO2 equivalents/year(1).Estimated release of pentafluoroethane into the atmosphere over Europe was inferred from atmospheric measurements collected April to Oct 2009 from locations in Italy, Ireland and Switzerland(1). Regions were defined as: central west (Belgium, France, Luxembourg), central north (Denmark, Germany, The Netherlands), northwest (Ireland, United Kingdom), central south (Austria, Italy, Switzerland), southeast (Albania, Bulgaria, parts of Greece, Hungary, Romania, former Yugoslavia), northeast (Czech Republic, Poland, Slovakia), east (Belarus, Latvia, Lithuania, Moldova, western part of Ukraine), and southwest (Portugal, Spain)(1).[Table#6248]
EPA IRIS InformationPentafluoroethane
Soil Adsorption/MobilityUsing a structure estimation method based on molecular connectivity indices(1), the Koc of pentafluoroethane can be estimated to be 140(SRC). According to a classification scheme(2), this estimated Koc value suggests that pentafluoroethane is expected to have high mobility in soil.
Human Toxicity Excerpts/SIGNS AND SYMPTOMS/ Freons are toxic to humans by several mechanisms. Inhaled fluorocarbons sensitize the myocardium to catecholamines, frequently resulting in lethal ventricular arrhythmias. Because they are gases heavier than air, fluorocarbons can displace atmospheric oxygen, thus resulting in asphyxiation. These compounds also have a central nervous system anesthetic effect analogous to a structurally similar general anesthetic, halothane. Pressurized refrigerant or liquid fluorocarbons with a low boiling point have a cryogenic effect on exposed tissues, causing frostbite, laryngeal or pulmonary edema, and gastrointestinal perforation. /Freons//GENOTOXICITY/ A ... chromosomal aberration test was carried out in human lymphocytes exposed up to 700,000 ppm (3,436,000 mg/cu m) HFC-125 for 3, 24 and 48 hours, with and without metabolic activation. This study gave clearly negative results.
Artificial Pollution SourcesPentafluoroethane's production and use as a fire extinguisher and dry etching agent(1) may result in its release to the environment through various waste streams(SRC).
Environmental BiodegradationAEROBIC: Pentafluoroethane, present at 2.99 mg/L, reached 10% of its theoretical oxygen demand in 28 days using an activated sludge inoculum in the OECD 301D test(1).ANAEROBIC: Bacterial consortia were able to dechlorinate 1,1,2-trichloro-1,2,2-trifluoroethane under anaerobic conditions to chlorotrifluoroethane, but no biologically catalyzed defluorination reactions were observedthis indicates that pentafluoroethane is not likely to be biodegraded anaerobically(1).PURE CULTURE: Pentafluoroethane was not biodegraded in an aerobic degradation analysis using Mycobacterium vaccae JOB5. M. vaccae is a naturally occurring bacteria that has been shown to biodegrade chlorinated compounds(1).
Environmental BioconcentrationAn estimated BCF of 5 was calculated in fish for pentafluoroethane(SRC), using an estimated log Kow of 1.55 and a regression-derived equation(1). According to a classification scheme(2), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).
Volatilization from Water/SoilThe Henry's Law constant for pentafluoroethane is estimated as 0.049 atm-cu m/mole(SRC) using a fragment constant estimation method(1). This Henry's Law constant indicates that pentafluoroethane is expected to volatilize rapidly from water surfaces(2). Based on this Henry's Law constant, the volatilization half-life from a model river (1 m deep, flowing 1 m/sec, wind velocity of 3 m/sec)(2) is estimated as 3.2 hours(SRC). The volatilization half-life from a model lake (1 m deep, flowing 0.05 m/sec, wind velocity of 0.5 m/sec)(2) is estimated as 4.3 days(SRC). Pentafluoroethane's Henry's Law constant indicates that volatilization from moist soil surfaces may occur(SRC). Pentafluoroethane is expected to volatilize from dry soil surfaces(SRC) based upon a vapor pressure of 9501 mm Hg(3).
Non-Human Toxicity Excerpts/LABORATORY ANIMALS: Acute Exposure/ ... 10 Sprague Dawley rats (5 males and 5 females) were exposed to 800,000 ppm (3,927,000 mg/cu m) HFC-125 in atmosphere for 4 hours. Another 10 animals were exposed to normal air for control. No mortality was observed within 14 days after the exposure. During the exposure, clinical signs typical of an anesthetic effect, such as abnormal respiration and ataxic gait, were observed. These effects disappeared within 1 hour after the end of the exposure period. A slight decrease in mean body weight was registered in the exposed males, in comparison with the control males. No remarkable findings were observed during the autopsy. The lowest lethal dose (LDLo) was > 800,000 ppm (highest dose tested) for this study./LABORATORY ANIMALS: Acute Exposure/ Cardiac sensitization potential of HFC-125 following adrenaline injection was studied in beagle dogs. The animals were initially tested for cardiac sensitivity to adrenaline alone, in order to establish the response dose (varying from 1 to 12 ug/kg for different animals). HFC-125 effects were compared to Halon 13B1 and to the reference (positive control) CFC-11. CFC-11 at a concentration of 25,000 ppm (122,720 mg/cu m) in air gave fatal ventricular fibrillation and multiple ectopic beats in 2/2 tested dogs. Six dogs were first exposed to 50,000 Halon 13B1, and then the same dogs were exposed to 100,000 HFC 125these dogs were alternately exposed to increasing concentrations of Halon 13B1 and HFC 125. The same dogs were used for each successive exposure until a clear positive response was observed (5 or more apparently multifocal ventricular ectopic beats or ventricular fibrillation). Any dog with a positive response was removed from the experimentit was assumed that the dogs exhibiting a positive response would also exhibit positive responses at all higher concentrations of the subject compound. Halon 13B1 and HFC-125 gave positive responses at 200,000 ppm (981,759 mg/cu m) (2/6 animals) and 100,000 ppm (490,879 mg/cu m) (1/6 animals), respectively. In this study the EC50 of HFC-125 for cardiac sensitization potential was between 100,000 and 150,000 ppm (490,879 and 736,319 mg/cu m) in air, and the NOEC was 75,000 ppm (368.160 mg/cu m). Two dogs exposed respectively to 200,000 and 300,000 ppm HFC-125 showed fatal ventricular fibrillation. A similar study was performed with a mixture of 36.5/63.5% v/v HFC-23/HFC-125. Exposure to 100,000 ppm (490,879 mg/cu m) of this mixture in air gave a positive response (fatal ventricular fibrillation) in one of six dogs./LABORATORY ANIMALS: Subchronic or Prechronic Exposure/ In 13-week study, groups of 10 male and 10 female Sprague-Dawley rats were exposed to 0, 5,000, 15,000 and 50,000 ppm (0, 24.544, 73,632 and 245,440 mg/cu m) HFC-125 (6 hrs/day, 5 days/week). Additional groups of 10 male and 10 female rats were designated for a 4-week recovery period. No mortality was found at any dose. There were no treatment-related clinical signs of toxicity or significant differences in body weight gains and food consumption among the control and the treated groups. No statistical differences were observed in hematology, blood biochemistry and urinalysis, in organ weights and in peroxisomal beta-oxidation activities. Gross pathology examinations revealed a white patch in the liver of one male and a cyst in the kidney of another male dosed at 50,000 ppm and thick ear of one female of 5,000 ppm group, one of 50,000 ppm group and one in the control group. Enlargement of the lymph node in one female and a cyst in the ovary of another female were observed in the 50,000 ppm group at the end of the recovery period. These findings were considered incidental. No treatment-related histopathological changes were observed and 50,000 ppm, was considered the NOAEC for this study./LABORATORY ANIMALS: Subchronic or Prechronic Exposure/ Groups of 10 male and 10 female Sprague Dawley rats were exposed to 0, 5000, 15,000 and 50,000 ppm (0, 24.544, 73,632 and 245,440 mg/cu m) HFC-125 for 28 days (6 hours/day, 5 days/week). Two additional groups were exposed to 0 and 50,000 ppm HFC-125 and were allowed to recover for two weeks after the exposure period. No mortality was observed in this study. There were no treatment-related clinical signs of toxicity and differences in body weight and food consumption among the treated and the control groups, neither after the exposure nor after the recovery period. Some effects were observed in the hematology and blood chemistry analysis. In particular, a very slight, not dose-related increase in mean corpuscular hemoglobin concentration was measured in the males of all the treatment groups at the end of the exposure periodonly the increase at the highest dose was statistically significant in comparison with the controls. Males exposed to 5,000 and 15,000, but not to 50,000 ppm, showed a slightly lower serum albumin content. A slight increase in serum phospholipids concentration was measured in the males of high-dosed group, at the end of exposure period. No hematological findings were observed in the recovery groups. Neither macroscopic nor microscopic changes were observed during gross pathology and histological examinations, respectively. Study of peroxisomal proliferation gave equivocal results, since a slightly higher activity of peroxisomal beta-oxidation was measured in the males of the high-dosed group in comparison to controlwhile a lower activity was measured in the females of the same group.For more Non-Human Toxicity Excerpts (Complete) data for PENTAFLUOROETHANE (10 total), please visit the HSDB record page.
TSCA-Inventar-StatusTSCA listed
UN-TransportnummerUN 3220 (PENTAFLUOROETHANE (REFRIGERANT GAS R 125))
Zollcode2903440010
RTECS-Nr.KI6365000
ToxizitätLC50 inhalation in mouse: 2735gm/m3/2H
GefahrensymboleXi
hazard_noteIrritant
Sicherheitshinweise (S)23-38
Gefahrenklasse2.2
Gefahrstoffdaten354-33-6(Hazardous Substances Data)

Anwendungen & Verwendung

Verwenden

HFC 125s main application is as a high-pressure refrigerant. It has also found use as a total flooding fire-extinguishing agent.