Beteiligte Stoffe
| Rolle | Name | HCID | Einwaage |
|---|
| Edukt | Methylhydroquinone | HCID 7253 | — |
| Edukt | Trimethylhydroquinone | HCID 12785 | — |
| Edukt | 2,3-Dimethylhydroquinone | HCID 69100 | — |
| Katalysator | Zinc | HCID 23994 | — |
| Lösungsmittel | Methanol | HCID 887 | — |
| Produkt | Durohydroquinone | HCID 136346 | — |
Reaktionsschritte
Into an autoclave (inner volume: 9 ml, made of SUS 316, equipped with a manometer) were charged 0.092 g of methylhydroquinone, 3.895 g of methanol and 7.2 mg of zinc powders (manufactured by High Purity Chemicals Co.). The reaction was started by elevating the temperature up to 350° C. with sand bath. The pressure during the reaction was 17 MPa. After 2 hours, the autoclave was quickly cooled and the reaction solution was taken out from the autoclave when the temperature was cooled back to the room temperature. The measurement according to the process described above revealed that the conversion of methylhydroquinone was 23% by mole, the selectivity of dimethylhydroquinone was 92% by mole, the selectivity of trimethylhydroquinone was 8% by mole and no tetramethylhydroquinone was produced.
Herkunft & Nachweise
| DOI | 10.6084/m9.figshare.5104873.v1 |
|---|
| Patentnummer | US06303801B1 |
|---|
| Quelldatensatz | uspto-grants-2001_10 |
|---|
| ORD ID | ord-2e8d7521a058424daad922cc8427032b |
|---|
| Quellennotiz | uspto-grants-2001_10 |
|---|