Zurück
HuagongsheHuagongshe Chemie-Druckbericht · Nur für Forschungszwecke
HRID 441282Erstellt: 24. Oktober 2026

Nitrate → Zinc Phosphate

https://huagongshe.com/de/reaction/441282

Reaktionsgleichung

Beteiligte Stoffe

RolleNameHCIDEinwaage
EduktNitrateHCID 943—
EduktNitriteHCID 946—
EduktPhosphoric AcidHCID 1004—
EduktPhosphateHCID 1061—
EduktZincHCID 23994—
EduktFluoride IonHCID 28179—
KatalysatorNickelHCID 935—
LösungsmittelWaterHCID 962—
ProduktZinc PhosphateHCID 24519—

Reaktionsbedingungen

Temperatur150 fahrenheit

Reaktionsschritte

An aqueous acidic zinc phosphate coating solution was prepared in a five-gallon laboratory spray tank to contain 1.2 g/l zinc ions, 1.0 g/l nickel ions, 1.0 g/l fluoride added as silicofluoride, 5.0 g/l phosphate ions, 2.0 g/l nitrate ions, and 0.1 g/l nitrite ions. This solution, when heated to 150° F., and when titrated in the conventional manner, was found to have a total acid of between 13.0 and 14.6 points, and a free acid of between 1.0 and 1.3 points. In a second spray tank, a conventional alkaline cleaner was prepared at a concentration of one ounce per gallon and was heated to 145°-150° F. A third spray tank was used to contain the melamine-formaldehyde resin/tannin post-treatment solutions detailed in Table XVIII. A number of 4 × 12 inch SAE 1010, cold rolled steel panels (CRS) and 4 × 12 inch minimum spangle commercial hot-dipped galvanized panels (GALV), temper rolled one percent, were sprayed in the sequence one minute cleaner, one-half minute fresh warm water spray rinse, 1 minute zinc phosphate solution, one-half minute cold water rinse, and one-half minute melamine-formaldehyde resin/tannin solution detailed in the table, after which they were dried in a circulating air oven for 5 minutes at 325° F. Control panels were prepared in the same manner except that they were oven dried following a one-half minute tap water rinse and a one-half minute deionzed water rinse, or alternatively treated in a commercial post-treatment solution containing about 0.04% chromic acid at a pH of about 4 at 80° F. for one-half minute following the cold water rinse and oven dried. Other control panels were prepared in the same manner except that they were treated in a solution containing 0.25 g/l of tannin T9 at a pH of 4.6 (adjusted with H3PO4) at 80° F. for one-half minute following the cold water rinse and oven dried. In this example, all panels were oven dried for 5 minutes at 325° F.

Herkunft & Nachweise

DOI10.6084/m9.figshare.5104873.v1
PatentnummerUS04039353
Quelldatensatzuspto-grants-1977_08
ORD IDord-f299400b74c84b91b45043d4178269d6
Quellennotizuspto-grants-1977_08