Zurück
HuagongsheHuagongshe Chemie-Druckbericht · Nur für Forschungszwecke
HRID 989069Erstellt: 25. Oktober 2026

Hydrochloric Acid → Paroxetine HCl Ethanol

https://huagongshe.com/reaction/989069

Reaktionsgleichung

Beteiligte Stoffe

RolleNameHCIDEinwaage
EduktHydrochloric AcidHCID 313—
EduktParoxetineHCID 43815—
LösungsmittelEthanolHCID 702—
ProduktParoxetine HCl EthanolHCID 69742865—

Reaktionsschritte

To a reaction flask containing 100 ml of absolute ethanol was added 13.9 g of paroxetine base. The flask was shaken until a clear solution was obtained. To this paroxetine solution, 10 ml of a solution of hydrochloric acid in absolute ethanol (22% v/v) was added dropwise. As the reaction proceeded to completion, the color of the solution changed from a yellow brown to a pink brown. The product was then vacuum dried in a rotary evaporator. A foamy, amorphous solid was obtained (lot # W951027). The produced amorphous solid was subjected to an additional 2.5 days of drying in a desiccator at reduced pressure. The solid, a free-flowing powder, was tested for composition by NMR and FTIR. The findings were consistent with published spectra for paroxetine. Silver nitrate testing of the solid indicated the presence of chloride in the sample. Volatile analysis by gas chromatography revealed that the amount of ethanol present in the amorphous solid was 4% by weight. Residual moisture was determined by Karl-Fisher coulometric method at 0.7%. HPLC analysis revealed the material was >99% pure and essentially free from contamination. X-ray powder crystallography was conducted on the sample and produced the diffraction pattern shown in FIG. 1. X-ray powder diffraction was performed using the powder pack method. The powder patterns were obtained using a Philips PW1710 automated diffractometer, with monochromatized CuKα, (Kα1=1.54060 Å; Kα2=1.54438 Å) radiation. The diffractometer was equipped with a compensating slit and a graphite monochromator. It was calibrated to 0.02° (2θ) using the quartz peak at 26.66θ° (2θ). The minimum peak/background ratio was 0.75. This spectrum is consistent with an amorphous solid form. The halo effect is clearly seen and the intensity is small. Differential scanning calorimetry was performed on the solid at two different heating rates. The results indicate an endotherm at 48 degrees Celsius (heat flow) with and absence of other endotherms (FIG. 3A and FIG. 3B). Visual examination showed a “glassing” of the solid at this temperature.

Herkunft & Nachweise

DOI10.6084/m9.figshare.5104873.v1
PatentnummerUS06638948B1
Quelldatensatzuspto-grants-2003_10
ORD IDord-a19526a788ac44a5a4453e429de627fb
Quellennotizuspto-grants-2003_10