521-31-3Nc1cccc2c(=O)[nH][nH]c(=O)c12HWYHZTIRURJOHG-UHFFFAOYSA-NO-aminophthalyl hydrazide appears as yellow crystals or light beige powder. (NTP, 1992)
521-31-3DTXSID5024504CHEMBL442329O-aminophthalyl hydrazide appears as yellow crystals or light beige powder. (NTP, 1992)
Yellow or light beige solid; [CAMEO] Light yellow powder; [Sigma-Aldrich MSDS]
This chemical does not meet GHS hazard criteria for 1.7% (1 of 59) of reports.
Warning
H302 (15.3%): Harmful if swallowed [Warning Acute toxicity, oral]
P261, P264, P264+P265, P270, P271, P280, P301+P317, P302+P352, P304+P340, P305+P351+P338, P319, P321, P330, P332+P317, P337+P317, P362+P364, P403+P233, P405, and P501 (click each P-code to see the statement)
Aggregated GHS information provided per 59 reports by companies from 11 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.
Chemical: 1,4-Phthalazinedione, 5-amino-2,3-dihydro-
5-Amino-2,3-dihydro-1,4-phthalazinedione: Does not have an individual approval but may be used under an appropriate group standard
Substances used for the detection, identification, analysis, etc. of chemical, biological, or pathologic processes or conditions. Indicators are substances that change in physical appearance, e.g., color, at or approaching the endpoint of a chemical titration, e.g., on the passage between acidity and alkalinity. Reagents are substances used for the detection or determination of another substance by chemical or microscopical means, especially analysis. Types of reagents are precipitants, solvents, oxidizers, reducers, fluxes, and colorimetric reagents. (From Grant & Hackh's Chemical Dictionary, 5th ed, p301, p499)
Compound such as LUMINESCENT PROTEINS that cause or emit light (PHYSICAL LUMINESCENCE).
Uses1. It can be used as chemical analysis reagents, indicators. 2. It can be used for chemiluminescence analysis such as measurement of metal cations, blood and glucocorticoids
UsesLuminol is a chemiluminescent probe that has been used to detect myeloperoxidase-mediated oxidative events in granulocytes and for chemiluminescence analysis of metal cations and blood.
UsesLuminol is used in the detection of copper, iron, peroxides and cyanides. It exhibits chemiluminescence and utilized to measure opsonic and phagocytic function. It acts as a biological sensor and involved in the detection of polymorphonuclear leukocytes response in a patient with a myeloperoxidase deficiency. Further, it is used as a forensic test for blood.
UsesDetection of copper, iron, peroxides, cyanides.
Loading…
EYES: First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop.
SMALL SPILLS AND LEAKAGE: If you spill this chemical, FIRST REMOVE ALL SOURCES OF IGNITION, then dampen the solid spill material with toluene, then transfer the dampened material to a suitable container. Use absorbent paper dampened with toluene to pick up any remaining material. Your contaminated clothing and absorbent paper should be sealed in a vapor-tight plastic bag for eventual disposal. Solvent-wash all contaminated surfaces with toluene followed by washing with a soap and water solution. Do not reenter the contaminated area until the Safety Officer (or other responsible person) has verified that the area has been properly cleaned.
RECOMMENDED RESPIRATOR: Where the neat test chemical is weighed and diluted, wear a NIOSH-approved half face respirator equipped with an organic vapor/acid gas cartridge (specific for organic vapors, HCl, acid gas and SO2) with a dust/mist filter. (NTP, 1992)
General DescriptionYellow crystals or light beige powder.