Hydrazoic acid

HCID 24530

Basic information

CAS
7782-79-8
Standard SMILES
[N-]=[N+]=N
InChIKey
JUINSXZKUKVTMD-UHFFFAOYSA-N
Molecular formula
HN3
Average molar mass
43.029 g/mol
Monoisotopic mass
43.01704703

Overview

Hydrogen azide is a nitrogen hydride. It is a conjugate acid of an azide anion.

Names & identifiers

Preferred name
Hydrazoic acid
IUPAC
Triaza-1,2-dien-2-ium-1-ide
English name
Hydrazoic acid
Molecular formula
HN3
Molecular weight
43.02804

Names & synonyms

HYDRAZOIC ACIDHydrogen azideTriazoic acidAzoimideHydronitric acid7782-79-8DiazoimideStickstoffwasserstoffsaeure6P5C4D5D7IAZIDIC ACIDCHEBI:29449DTXSID20884425
Show more names
1H-TriazirineAzide acidHydrazoic acid (as vapour)Hydrazoic acid ISO 9001:2015 REACH
RefChem:147036DTXCID701023866231-965-8[NNNH]CHEMBL186537N3HStickstoffwasserstoffsaeure [German]EINECS 231-965-8

Database identifiers

CAS
7782-79-8
PubChem CID
24530
DTXSID
DTXSID20884425
ChEMBL
CHEMBL186537
ChEBI
CHEBI:29449
UNII
6P5C4D5D7I
EC Number
231-965-8
Nikkaji
J2.255.096I、J59.889E

Properties

Computed structural properties

XLogP
1.7
Topological polar surface area
25.9 Ų
Hydrogen bond donors
1
Hydrogen bond acceptors
2
Rotatable bonds
0
Heavy atoms
3

Experimental & physicochemical properties

Chemical ClassesOther Uses -> Explosives
Odor · 2 items

Obnoxious odor

Intolerable pungent odor

Density · 2 items

Specific gravity: 1.09 at 25 °C/4 °C

1.09

Color/FormColorless liquid
Boiling Point · 2 items

35.7 °C

96.26 °F

DecompositionWhen heated to decomposition it emits toxic fumes of /nitrogen oxide/.

Physicochemical properties

Melting point
-80 ° · -80°
Boiling point
37 ° · bp 37°
Density
1.092 · 1.092
solubility
2 O · soluble in H2O
pka
4.72 · 4.72(at 25℃)
form
colorless liquid

Safety & regulation

GHS classification

GHS Classification · 3 items

Danger

H200: (Deleted) Unstable Explosive [Danger Explosives]

P201, P202, P260, P261, P264, P264+P265, P270, P271, P280, P281, P304+P340, P305+P351+P338, P308+P316, P319, P321, P337+P317, P372, P373, P380, P401, P403+P233, P405, and P501 (click each P-code to see the statement)

Hazard information

Regulatory InformationChemical: Hydrazoic acid
Fire PotentialDangerously explosive material.
Hazards Summary · 1 item

Causes convulsions and structural or functional changes in trachea or bronchi in inhalation lethal-concentration studies of mice; Human inhalation of 300 ppb (0.3 ppm) causes changes in recordings from specific areas of the CNS, somnolence, and change in cardiac rate; [RTECS] Extremely explosive; An eye irritant; May cause cough, headache, fall in blood pressure, weakness, and collapse; Chronic exposure may cause hypotension, palpitation, and ataxia; [Merck Index] A severe skin, eye, and mucous membrane irritant; [HSDB] See Sodium azide.

Toxic Combustion ProductsPoisonous gases, including nitrogen oxides, are produced in fire.
NIOSH RecommendationsRecommended Exposure Limit: Ceiling Value: 0.1 ppm (as NH3); skin. /Sodium azide/
Hazard Classes and CategoriesExplosives - Unstable Explosive

Safety & protection

Exposure Control and Personal Protection0.18 [mg/m3]
Fire Fighting Procedures · 1 item

Containers may explode in fire. Storage containers and parts of containers may rocket great distances, in many directions. If material or contaminated runoff enters waterways, notify downstream users or potentially contaminated waters. Notify local health and fire officials and pollution control agencies. From a secure, explosion-proof location use water spray to cool exposed containers. If cooling streams are ineffective (venting sound increases in volume and pitch, tank discolors or shows any signs of deforming), withdraw immediately to a secure position ... The only respirators recommended for fire fighting are self-contained breathing apparatuses that have full facepieces and are operated in a pressure-demand or other positive-pressure mode.

Storage ConditionsStore in tightly closed containers in a cool, well ventilated area away from incompatible materials ... Protect from heat or shock.
Cleanup Methods · 1 item

Evacuate and restrict persons not wearing protective equipment from area of spill or leak until clean-up is complete. Remove all ignition sources. Ventilate area of spill or leak. Absorb liquids in vermiculite, dry sand, earth, peat, carbon, or a similar material and deposit in sealed containers. Keep the chemical out of a confined space, such as a sewer, because of the possibility of an explosion, unless the sewer is designed to prevent the build-up of explosive concentrations. It may be necessary to contain and dispose of this chemical as a hazardous waste. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Contact your Department of Environmental Protection or your regional office of the federal EPA for specific recommendations.

Disposal Methods · 2 items

SRP: The most favorable course of action is to use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination. Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in soil or water; effects on animal and plant life; and conformance with environmental and public health regulations.

May be destroyed by converting hydrazoic acid to sodium azide and the reaction mixture decomposed with nitrous acid.

Preventive Measures · 3 items

SRP: The scientific literature for the use of contact lenses by industrial workers is inconsistent. The benefits or detrimental effects of wearing contact lenses depend not only upon the substance, but also on factors including the form of the substance, characteristics and duration of the exposure, the uses of other eye protection equipment, and the hygiene of the lenses. However, there may be individual substances whose irritating or corrosive properties are such that the wearing of contact lenses would be harmful to the eye. In those specific cases, contact lenses should not be worn. In any event, the usual eye protection equipment should be worn even when contact lenses are in place.

SRP: Contaminated protective clothing should be segregated in such a manner so that there is no direct personal contact by personnel who handle, dispose, or clean the clothing. The completeness of the cleaning procedures should be considered before the decontaminated protective clothing is returned for reuse by the workers. Contaminated clothing should not be taken home at the end of shift, but should remain at employee's place of work for cleaning.

SRP: Wastewater from contaminant suppression, cleaning of protective clothing/equipment, or contaminated sites should be contained and evaluated for subject chemical or decomposition product concentrations. Concentrations shall be lower than applicable environmental discharge or disposal criteria. Alternatively, pretreatment and/or discharge to a permitted wastewater treatment facility is acceptable only after review by the governing authority and assurance that "pass through" violations will not occur. Due consideration shall be given to remediation worker exposure (inhalation, dermal and ingestion) as well as fate during treatment, transfer and disposal. If it is not practicable to manage the chemical in this fashion, it must be evaluated in accordance with EPA 40 CFR Part 261, specifically Subpart B, in order to determine the appropriate local, state and federal requirements for disposal.

Toxicology

Environmental Fate · 3 items

TERRESTRIAL FATE: Based on a classification scheme(1), an estimated Koc value of 3(SRC), determined from a structure estimation method(2), indicates that hydrazoic acid is expected to have very high mobility in soil(SRC). The pKa of hydrazoic acid is 4.72(3), indicating that this compound will exist almost entirely in anion form in the environment and anions generally do not adsorb more strongly to soils containing organic carbon and clay than their neutral counterparts(4). Volatilization from moist soil is not expected because the acid exists as an anion and anions do not volatilize(SRC). Hydrazoic acid is expected to volatilize from dry soil surfaces(SRC) based upon an estimated vapor pressure of 484 mm Hg at 25 °C(SRC), determined from a fragment constant method(5). Biodegradation data in soil were not available(SRC, 2010).

AQUATIC FATE: Based on a classification scheme(1), an estimated Koc value of 3(SRC), determined from a structure estimation method(2), indicates that hydrazoic acid is not expected to adsorb to suspended solids and sediment(SRC). A pKa of 4.72(3) indicates hydrazoic acid will exist almost entirely in the anion form at pH values of 5 to 9 and therefore volatilization from water surfaces is not expected to be an important fate process(4). According to a classification scheme(5), an estimated BCF of 3(SRC), from an estimated log Kow of 1.16(6) and a regression-derived equation(7), suggests the potential for bioconcentration in aquatic organisms is low(SRC). Biodegradation data in water were not available(SRC, 2010).

ATMOSPHERIC FATE: According to a model of gas/particle partitioning of semivolatile organic compounds in the atmosphere(1), hydrazoic acid, which has an estimated vapor pressure of 484 mm Hg at 25 °C(SRC), determined from a fragment constant method(2), is expected to exist solely as a vapor in the ambient atmosphere. Vapor-phase hydrazoic acid is degraded in the atmosphere by reaction with photochemically-produced hydroxyl radicals(SRC); the half-life for this reaction in air is estimated to be 4 to 12 days(SRC), calculated from rate constants of 3.9X10-12(3) and 1.3X10-12(4) cu cm/molecule-sec. Direct photolysis of hydrazoic acid in the gaseous phase by sunlight has a half-life of 52 hours(4).

Adverse EffectsOther Poison - Chemical Asphyxiant
Effluent ConcentrationsHydrazoic acid is released upon deployment of air bags with measured concentrations of 0.15-7.3 ppm (each gram of sodium azide generates 0.56 L nitrogen at 25 °C and 1 atmosphere)(1).
Soil Adsorption/Mobility · 1 item

Using a structure estimation method based on molecular connectivity indices(1), the Koc of hydrazoic acid can be estimated to be 3(SRC). According to a classification scheme(2), this estimated Koc value suggests that hydrazoic acid is expected to have very high mobility in soil. Hydrazoic acid has been reported to be quite mobile and readily leachable in most soils(3).

Human Toxicity Excerpts · 3 items

/SIGNS AND SYMPTOMS/ Short Term Exposure: Irritating to skin, eyes, and respiratory tract. Continued inhalation causes cough, headache, dizziness, weakness, fall in blood pressure, chills and fever, and collapse. Prolonged exposure to high concentration can cause fatal convulstions and death. Highly toxic. Long Term Exposure: Chronic exposure can affect the central nervous system: hypotension, palpitation, ataxia, and weakness.

/CASE REPORTS/ ... This article is a case report on two young male workers, who were unloading drums of sodium azide powder when they accidentally inhaled the powder while cleaning up the material. Hypotension, nausea, vomiting and weakness were the symptoms experienced, followed by a persistent reactive airway dysfunction syndrome. It has been postulated that both sodium azide and hydrazoic acid contributed to the observed adverse effects.

/SURVEILLANCE/ ... In 1994-1995, the National Institute for Occupational Safety and Health (NIOSH) conducted a cross-sectional study of health complaints reported by sodium azide production workers at the only continuous sodium azide production facility in the United States. The NIOSH evaluation consisted of a plant industrial hygiene survey, a symptom questionnaire, ambulatory blood pressure monitoring, and blood azide analysis. Personal breathing zone air monitoring revealed exposures to sodium azide and hydrazoic acid (a reactant product) at levels greater than the NIOSH Recommended Exposure Limits (RELs). In some cases, exposures exceeded the REL despite the use of air-supplied respirators. The questionnaire revealed that most workers reported headache (10 of 11 [91%]), episodes of low blood pressure (9 of 11 [82%]), and palpitations (8 of 11 [73%]) occurring in the production areas within the 6 months preceding the study. Mild headache (4 of 11 [36%]) was the only symptom reported during our 24-hr medical survey. Ambulatory blood pressure monitoring revealed one asymptomatic employee with a drop in blood pressure (defined as a drop in systolic [at least 20 mm Hg] and diastolic [at least 10 mm Hg] blood pressure) during a period of exposure to sodium azide at a level five times the NIOSH REL. Improvements in plant engineering controls, increased attention to employee hygiene practices, and a more comprehensive respiratory protection program were recommendations made by NIOSH to reduce exposures at the plant. All facilities handling sodium azide should be aware of the potential toxicity of sodium azide and hydrazoic acid.

Artificial Pollution Sources · 1 item

Hydrazoic acid's production and use as a chemical intermediate for heavy metal azides(1) may result in its release to the environment through various waste streams(SRC). It is formed upon deployment of air bags that use sodium azide as an inflating agent and sodium azide also forms hydrazoic acid rapidly in its use as a biocide(2), resulting in its direct release to the environment(SRC).

Safety data

tsca
TSCA listed
ridadr
0473
Toxicity
LD50 in mice (mg/kg): 21.5 i.p. (Graham)
hazard_class
1.1A
Hazardous Substances Data
7782-79-8(Hazardous Substances Data)

Chemistry & industry

Uses & manufacturing

Uses · 2 items

Used to make heavy metal azides for shell detonators; [Merck Index] Produced from sodium azide on deployment of air bags (inflating agent) and from its use as a biocide; [HSDB]

Industrially in preparation of heavy metal azides for shell detonators

Methods of Manufacturing · 2 items

Reaction of hydrazine and nitrous acid, or of nitrous oxide and sodium amide (with heat)

Produced by the action of sulfuric acid on sodium azide.

General Manufacturing InformationHydrazoic acid: ACTIVE
Applications · 3 items

DescriptionHydrazoic acid or hydrogen azide is a dangerous explosion risk when shocked or heated. It is the gas-forming agent in many air bag systems in automobiles and escape chutes in airplanes.

UsesHydrazoic acid is used in making heavymetal azides for detonators. It forms readilywhen sodium azide reacts with acid orhydrazine is mixed with nitrous acid.

UsesIndustrially in preparation of heavy metal azides for shell detonators.

Preparation methods

PreparationHydrazoic acid is prepared by reacting sulfuric acid with sodium azide: H2SO4 + NaN3 → HN3 + Na2SO4 or by treating hydrazine with nitrous acid: N2H4 + HNO2 → HN3 + 2H2O or by heating sodium amide with nitrous oxide: NaNH2 + N2O → HN3 + NaOH

Upstream & downstream products

Suppliers6 total

陕西麟邦实业有限公司17709134430 · [email protected]
陕西缔都医药化工有限公司+86-29-81139210 +86-17392587031 · [email protected]
河南天孚化工有限公司+86-0371-55170693 +86-19937530512 · [email protected]
厦门盈融达化工有限公司+86-0592-6210733 · [email protected]
陕西缔都医药化工有限公司029-029-029-81148696 18161915376 · [email protected]
Additional notes · 1 item

DefinitionA colorless liquid with a nauseating smell. It is highly poisonous and explodes in the presence of oxygen and oxidizing agents. It can be made by distilling a mixture of sodium azide (NaN3) and a dilute acid. It is usually used as an aqueous solution. The salts of hydrazoic acid (azides), especially lead azide (Pb(N3)2), are used in detonators because of their ability to explode when given a mechanical shock.

Related reactions

94 records

Compound notes

Loading…