Dichlorofluoromethane

HCID 6370
New reaction
Print

Completing data — refresh the page later to see the latest

Basic informationOverviewNames & identifiersPropertiesSafety & regulationChemistry & industryRelated reactionsCompound notes
Substructure searchFind similar structures

Basic information

CAS
75-43-4
Standard SMILES
FC(Cl)Cl
InChIKey
UMNKXPULIDJLSU-UHFFFAOYSA-N
Molecular formula
CHCl2F
Average molar mass
102.92 g/mol
Monoisotopic mass
101.94393361

Overview

Dichlorofluoromethane is a colorless, odorless gas. It is shipped as a liquid under its own vapor pressure. Contact with the liquid may cause frostbite to unprotected skin. It can asphyxiate by displacement of air. Exposure of the container to prolonged heat or fire may cause it to rupture violently and rocket.

Names & identifiers

Preferred name
Dichlorofluoromethane
IUPAC
dichloro(fluoro)methane
English name
Dichloromonofluoromethane
Molecular formula
CHCl2F
Molecular weight
102.92

Names & synonyms

DichlorofluoromethaneFluorodichloromethane75-43-4DichloromonofluoromethaneAlgofrene type 5Arcton 7Genetron 21MonofluorodichloromethaneRefrigerant 21HCFC-21Methane, dichlorofluoro-Fluorocarbon 21
Show more names
CHCl2FCHFCl2f21F 21f-21fc21AF22FC 21
FREON 21Freon F 21R 21 (refrigerant)Halon 112DwuchlorofluorometanRacon 21FC-21HCFC 21

Database identifiers

CAS
75-43-4
PubChem CID
6370
DTXSID
DTXSID7052498
ChEMBL
CHEMBL116813
UNII
7GAO4CRJ0B
EC Number
200-869-8
Nikkaji
J1.454K

Properties

Computed structural propertiesFilling in

XLogP
2
Topological polar surface area
0 Ų
Hydrogen bond donors
0
Hydrogen bond acceptors
1
Rotatable bonds
0
Heavy atoms
4
Formal charge
0
Complexity
13.5

Experimental & physicochemical properties

Chemical ClassesVolatile Organic Compound (VOC)
SolventsSolvents -> Chlorofluorocarbons
SpringerMaterials PropertiesSchoenflies notation
LogP · 3 items

log Kow = 1.55

1.55

1.55

Odor... Slight ether-like odor ...
Density · 5 items

1.48 at 68 °F (USCG, 1999) - Denser than water; will sink

Density: 1.405 g/cu cm 9 °C

1.48

1.405 @ 9°C

3.57(relative gas density)

Viscosity0.313 cP at 25 °C (liq); 0.0114 cP at 25 °C, 101.3 kPa ... /gas/
Color/Form · 2 items

Colorless heavy gas

Colorless gas ... [Note: A liquid below 48 degrees F. Shipped as a liquefied compressed gas]

Solubility · 6 items

Safety & regulation

Safety information is for reference only and does not replace the supplier’s Safety Data Sheet (SDS), applicable regulations, or professional assessment.

GHS classification

GHS Classification · 6 items

This chemical does not meet GHS hazard criteria for 0.9% (1 of 114) of reports.

Warning

H280 (99.1%): Contains gas under pressure; may explode if heated [Warning Gases under pressure]

P410+P403, and P502 (click each P-code to see the statement)

Aggregated GHS information provided per 114 reports by companies from 6 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Danger

Hazard information

Regulatory Information · 3 items

Chemical: Methane, dichlorofluoro-

Dichlorofluoromethane: Does not have an individual approval but may be used as a component in a product covered by a group standard. It is not approved for use as a chemical in its own right.

The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)

DOT LabelNon-Flammable Gas
Fire Hazards · 3 items

Special Hazards of Combustion Products: Toxic fumes of chlorine and fluorine may be produced in fire. (USCG, 1999)

· Some may burn but none ignite readily.

Not combustible. Gives off irritating or toxic fumes (or gases) in a fire.

Fire PotentialWEAKLY FLAMMABLE.
Health Hazards · 2 items

INHALATION: May cause giddiness, light-headedness, disorientation, nausea, vomiting, narcosis, cardiac dysrhythmias, hypotension, and death. SKIN: May cause frostbite or irritation. EYES: May cause irritation or cold injury. (USCG, 1999)

· Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas.

Chemistry & industry

Pharmacology

Metabolism/MetabolitesInhalation pharmacokinetics of dichlorofluoromethane (CFC 21) and chlorodifluoromethane (CFC 22) were studied in male Wistar rats by use of a closed inhalation chamber system. CFC 21 was readily eliminated via metabolism....
Absorption, Distribution and Excretion · 4 items

... Main factor affecting fate of fluorocarbons is body fat, where they are concentrated and slowly released into blood at concentrations that should not cause any risk of cardiac sensitization. /Fluorocarbons/

... Both trichlorofluoromethane and dichlorofluoromethane admin as high acute inhalation dosages were expired unchanged by dogs and rabbits.

There is a significant accumulation of propellants in brain, liver and lung compared to blood levels, signifying a tissue distribution of fluorocarbons similar to that of chloroform. /Fluorocarbons/

Absorption of fluorocarbons is much lower after oral ingestion (35-48 times) than after inhalation. ... The lung generally have the highest fluorocarbon concn on autopsy. /Fluorocarbons/

Uses & manufacturing

Uses · 5 items

CFC-21 has been used as a solvent, refrigerant, and propellant. [ACGIH]

See CHLOROFLUOROCARBONS

Fully halogenated chlorofluorocarbons (CFCs) such as dichlorofluoromethane were scheduled for production phase-out in 1987 by the Montreal Protocol. Although originally scheduled for 50% production phase-out by the year 2000 in developed countries, the worsening ozone depletion has forced acceleration of the CFC phase-out.

Dichlorofluoromethane /HCFC-21/ has much less usage than other chlorofluorocarbons ... however, it has had application as a refrigerant in the aerospace industry, as a solvent, as propellant gas, and as a heat exchange fluid in geothermal energy applications.

Used as a refrigerant, solvent, propellant and heat-exchange fluid

Impurities · 1 item

Chlorofluoroalkanes (and also the alternative HCFCs and HFCs) produced on an industrial scale are subject to stringent standards. Impurities must not exceed the following limits (vol%): acids, 0; moisture, <0.001; higher-boiling fractions, <0.05; other gases, 2. /Chlorofluoroalkanes/

Related reactions

3 records
New reaction record
HRID 152880 reaction equation
HRID 152880As reactantTraining data from https://doi.org/10.1039/C8SC04228D (9/10)
HRID 848925 reaction equation
HRID 848925As reactantuspto-grants-1981_10
HRID 939611 reaction equation
HRID 939611As reactantValidation data from https://doi.org/10.1039/C8SC04228D

Compound notes

On this pageBasic informationOverviewNames & identifiersPropertiesSafety & regulationChemistry & industryRelated reactionsCompound notes

0.7 % at 86 °F (NIOSH, 2024)

In water, 1.88X10+04 mg/L at 25 °C

Soluble in carbon tetrachloride

69 parts/100 parts acetic acid; 108 parts/100 parts dioxane

> 10% in ethyl alcohol; > 10% in ethyl ether;> 10% in chloroform

0.95% weight at 25 deg in water

CorrosivityLiquid Refrigerant 21 will attack some forms of plastics, rubber, and coatings
Boiling Point · 6 items

48 °F at 760 mmHg (USCG, 1999)

8.9 °C

Heat of vaporization = 5.79 Kcal/mol at 25 °C; 6.01 kcal/mol at the boiling point

8.9 °C

48 °F

8.9 °C @760 [mm Hg]

Decomposition · 2 items

When heated to decomposition it emits very toxic fumes of chloride and fluoride.

Toxic gases and vapors (such as hydrogen chloride, phosgene, and hydrogen fluoride) may be released when it decomposes.

Physicochemical properties

Melting point
-135 °C · -135°C
Boiling point
8.9 °C · 8.9°C
Density
1 · 1,354 g/cm3
vapor pressure
1 · 1,216 at 11.8 °C (NIOSH, 1997)
refractive index
1.354 · 1.3540
solubility
Soluble in acetic acid, alcohol, and ether (Weast, 1986)
form
Colorless gas
color
Colorless liquid or gas with an ether-like odor
Water Solubility
0.7 wt · 0.7 wt % at 30 °C (NIOSH, 1997)
Thermal Conductivity
0.07 W/ · 0.07 W/(m·K)
Specific Heat Capacity
0.59 J/ · Cp(gas): 0.59 J/(g·K), at 25℃
Henry's Law Constant
9.1 · 9.1×10-4 mol/(m3Pa) at 25℃, HSDB (2015)
Exposure limits
10 ppm · ACGIH:TLV-TWA 10 ppm (42 mg/m3)OSHA:PEL-TWA 1000 ppm (4200 mg/m3)NIOSH:REL-TWA 10 ppm
Dielectric constant
5.3 · 5.3(28℃)
FDA UNII
7 GAO4CRJ0B · 7GAO4CRJ0B
NIST Chemistry Reference
Methane, dichlorofluoro-(75-43-4)
EPA Substance Registry System
-21 · HCFC-21 (75-43-4)
ECETOC JACC REPORT
Dichloromonofluoromethane (75-43-4)
Symbol(GHS)
4 · GHS04
Signal word
Danger
Hazard statements
280 · H280
Precautionary statements
410 · P410+P403
Hazard Codes
N
Risk Statements
59 · 59
Safety Statements
59 · 59
OEB
A
OEL
10 ppm · TWA: 10 ppm (40 mg/m3)
RIDADR
1029 · UN 1029 (DICHLOROFLUOROMETHANE (REFRIGERANT GAS R 21))
RTECS
8400000 · PA8400000
TSCA
TSCA listed
HazardClass
2.2 · 2.2
Hazardous Substances Data
75 · 75-43-4(Hazardous Substances Data)
Toxicity
50 · LC50 (inhalation) for rats 49,900 ppm/4-h (quoted, RTECS, 1985).
IDLA
5 · 5,000 ppm
Hazards SummarySee CHLOROFLUOROCARBONS; Possible frostbite from contact with liquid; [NIOSH] Inhalation of high concentrations may cause CNS effects; [ICSC] The substance may have effects on the liver. [ICSC]
DOT ID and Guide · 2 items

1029 126

1029 126

Reactive GroupFluorinated Organic Compounds
UN ClassificationUN Hazard Class: 2.2
Special Reports[WHO; Environmental Health Criteria 126: Partially Halogenated Chlorofluorocarbons (Methane Derivatives) (1991)]
TSCA Requirements · 1 item

Pursuant to section 8(d) of TSCA, EPA promulgated a model Health and Safety Data Reporting Rule. The section 8(d) model rule requires manufacturers, importers, and processors of listed chemical substances and mixtures to submit to EPA copies and lists of unpublished health and safety studies. Dichloromonofluoromethane is included on this list. Effective date: 4/13/89; Sunset date: 12/19/95.

OSHA Standards · 2 items

Permissible Exposure Limit: Table Z-1 8-hr Time Weighted Avg: 1000 ppm (4200 mg/cu m).

Vacated 1989 OSHA PEL TWA 10 ppm (40 mg/cu m) is still enforced in some states.

Safety & protection

Fire Fighting · 2 items

Excerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:

In case of fire in the surroundings, use appropriate extinguishing media. In case of fire: keep cylinder cool by spraying with water.

First Aid Measures · 3 items

Fresh air, rest. Artificial respiration may be needed. Refer for medical attention.

ON FROSTBITE: rinse with plenty of water, do NOT remove clothes. Refer for medical attention .

First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.

Accidental Release Measures · 2 items

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Do not touch or walk through spilled material.

First Aid · 3 items

Excerpt from NIOSH Pocket Guide for Dichloromonofluoromethane:

General First Aid:

(General first aid procedures)

Safe StorageFireproof if in building.
Exposure Control and Personal Protection · 2 items

· Wear positive pressure self-contained breathing apparatus (SCBA).

10.0 [ppm]

Fire Fighting Procedures · 1 item

If material involved in fire: Extinguish fire using agent suitable for type of surrounding fire. (Material itself does not burn or burns with difficulty.) Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible.

Storage Conditions... MATERIALS MUST BE STORED IN PLACES THAT ARE COOL ... PROVIDE ADEQUATE VENTILATION ... FURTHER PRECAUTION IS TO LOCATE ... AREA ... AWAY FROM AREAS OF FIRE HAZARD ... .
Cleanup MethodsIf Refrigerant 21 is spilled or leaked, the following steps should be taken: 1. Ventilate area of spill or leak. 2. If the gas is leaking, stop the flow. 3. If the liquid is spilled or leaked, allow to vaporize.
Nonfire Spill ResponseExcerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]:
Disposal Methods · 2 items

SRP: Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in air, soil or water; effects on animal, aquatic and plant life; and conformance with environmental and public health regulations. If it is possible or reasonable use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination.

Incineration, preferably after mixing with another combustible fuel. Care must be exercised to assure complete combustion to prevent the formation of phosgene. An acid scrubber is necessary to remove the halo acids produced.

Spillage DisposalPersonal protection: self-contained breathing apparatus. Do NOT let this chemical enter the environment. Ventilation. NEVER direct water jet on liquid.

Toxicology

Body Burden · 2 items

Personal air samples were collected from firefighters in Buffalo, NY while responding to 3 wood-frame building structure fires and one car fire; the range of dichlorofluoromethane detected in the breathing space varied from 0.67 to 12.1 ppm(1).

Dichlorofluoromethane was found in the expired air of 2 of 8 male volunteers; the amounts exhaled in these two subjects were 0.14 and 0.062 fg/hr(1). Dichlorofluoromethane was detected, but not quantified, in the expired air of a nonsmoking population of 62 males and females, suburban and urban residents(2). The percentage of subjects whose breath contained dichlorofluoromethane was not reported.

Interactions · 2 items

If inhalation occurs, epinephrine or other sympathomimetic amines and adrenergic activators should not be administered since they will further sensitize heart to development of arrhythmias. /Fluorocarbons/

Adrenaline should not be admin, because of the possibility of inducing cardiac arrhythmias or arrest. /Flourocarbons/

Target Organsrespiratory system, cardiovascular system
Environmental Fate · 3 items

TERRESTRIAL FATE: Based on a classification scheme(1), an estimated Koc value of 32(SRC), determined from a structure estimation method(2), indicates that dichlorofluoromethane is expected to have very high mobility in soil(SRC). Volatilization of dichlorofluoromethane from moist soil surfaces is expected to be an important fate process(SRC) given an estimated Henry's Law constant of 1.08X10-02 atm-cu m/mole(SRC), derived from its vapor pressure, 1.36X10+03 mm Hg(3), and water solubility, 1.88X10+04 mg/L(4). Dichlorofluoromethane exists as a gas above 9 °C and is expected to volatilize rapidly from dry soil surfaces based upon its vapor pressure(SRC). Dichlorofluoromethane has been observed to biodegrade under both aerobic and anaerobic conditions in various microcosm experiments using soil and sediment(5-7). Complete aerobic biodegradation of dichlorofluoromethane in soil by methanotrophic bacteria in 5-19 days has been reported(5).

AQUATIC FATE: Based on a classification scheme(1), an estimated Koc value of 32(SRC), determined from a structure estimation method(2), indicates that dichlorofluoromethane is not expected to adsorb to suspended solids and sediment(SRC). Volatilization from water surfaces is expected(3) based upon an estimated Henry's Law constant of 1.08X10-02 atm-cu m/mole derived from its vapor pressure, 1.36X10+03 mm Hg(4), and water solubility, 1.88X10+04 mg/L(5). Using this Henry's Law constant and an estimation method(3), volatilization half-lives for a model river and model lake are 3 hours and 4 days, respectively(SRC). According to a classification scheme(6), an estimated BCF of 2(SRC), from an estimated log Kow of 1.55(7) and a regression-derived equation(2), suggests the potential for bioconcentration in aquatic organisms is low(SRC). Dichlorofluoromethane has been observed to biodegrade under both aerobic and anaerobic conditions in various microcosm experiments using soil, aquatic sediment and sewage sludge(8-10). Approximately 93% and 50% degradation of dichlorofluoromethane in anoxic sediment samples collected from freshwater and saltwater wetlands occurred within 27 and 43 days, respectively, at 20 degrees(8). Rate constants for the neutral and alkaline hydrolysis reactions for dichlorofluoromethane are 2.1X10-10 and 5.4X10-09 L/mole-min, respectively(11); these rates correspond to a half-life of approximately 230 years(11).

ATMOSPHERIC FATE: According to a model of gas/particle partitioning of semivolatile organic compounds in the atmosphere(1), dichlorofluoromethane, which has a vapor pressure of 1.36X10+03 mm Hg at 25 °C(2), is expected to exist solely in the gas-phase in the ambient atmosphere. Gas-phase dichlorofluoromethane is degraded in the atmosphere by reaction with photochemically-produced hydroxyl radicals(SRC); the half-life for this reaction in air is estimated to be 1.5 years(SRC), calculated from its rate constant of 2.90X10-14 cu cm/molecule-sec at 25 °C(3).

Adverse EffectsNeurotoxin - Acute solvent syndrome
Exposure Routes · 2 items

The substance can be absorbed into the body by inhalation.

inhalation, skin and/or eye contact (liquid)

Toxicity Summary · 1 item

IDENTIFICATION AND USE: Dichlorofluoromethane is a colorless heavy gas that is used as a refrigerant, solvent, propellant and heat-exchange fluid. It is also referred to as CFC-21 but has fewer uses than other chlorofluorocarbons. HUMAN EXPOSURE AND TOXICITY: Inhalation of dichlorofluoromethane can cause confusion, drowsiness, and unconsciousness; and direct contact with skin can cause frostbite. Limited information was available on the toxicity and exposure to humans. One case study in which dicholorfluoromethane was one of the components of a water-repellent spray that was used in an insufficiently ventilated room by two young people, a 23 year man and his wife aged 21, who were admitted to the hospital with complaints of headache; nausea, dyspnea. Volatiles are frequently abused as inhalants. ANIMAL STUDIES: When administered alone to anesthetized mice at a concentration of 100,000 ppm, CFC-21 induced arrhythmia and sensitized the heart to epinephrine. Tachycardia with hypotension was observed in both monkeys and dogs that were anesthetized and exposed at 50,000-100,000 ppm. Bronchoconstriction was noted at 25,000 ppm. Repeated exposures have produced marked hepatic damage or failure. Ten of ten rats survived exposure at 10,000 ppm CFC-21, 6 hours per day, 5 days per week for 2 weeks, but their livers were grossly pale and heavy. Histopathologic examination showed centrilobular necrosis with related changes. In comparable 90-day series of exposure at 5000 and 1000 ppm levels, rats showed bilateral hair loss and excessive mortality (20 of 54 died at 1000 ppm, 15 of 54 at 5000 ppm). Four dogs exposed at both levels showed weight loss. Cirrhosis was evident in rats exposed at both levels, but with dogs histopathologic changes in the liver were mild and evident only at the 5000 ppm. CFC-21 has produced pre-implantation loss in pregnant rats exposed at 10,000 ppm. After exposure for 6 hr daily, on days 6 to 15 of gestation, 15 or 25 pregnant females had no viable fetuses or implantation sites on the uterine wall. Pregnancy outcome and fetal development in the other 10 rats were unaffected.

Signs and Symptoms · 3 items

Confusion. Drowsiness. Unconsciousness.

ON CONTACT WITH LIQUID: FROSTBITE.

asphyxia, cardiac arrhythmias, cardiac arrest; liquid: frostbite

Effluent Concentrations · 1 item

Dichlorofluoromethane was found in gases emanating from a simulated landfill(1); no quantitation was performed; the material in the simulated landfill consisted of municipal refuse and various loadings of municipal wastewater sludge(1). Dichlorofluoromethane was reported in landfill gas at a concentration of 93 mg/cu m(2); the site was a clay pit that received both municipal and industrial solid wastes, and liquid waste were at the sampling point(2). Dichlorofluoromethane was detected in municipal solid waste landfill gas at seven locations in the United Kingdom at concentrations ranging from 1-85 mg/cu m(3).

ICSC Environmental DataAvoid release to the environment because of its impact on the ozone layer.
Medical SurveillanceConsider the points of attack /respiratory system, lung, cardiovascular system/ in preplacement and periodic physical examinations.
Soil Adsorption/Mobility · 1 item

Using a structure estimation method based on molecular connectivity indices(1), the Koc for dichlorofluoromethane can be estimated to be 32(SRC). According to a classification scheme(2), this estimated Koc value suggests that dichlorofluoromethane is expected to have very high mobility in soil.

Regulatory information

TSCA Requirements · 1 item

Pursuant to section 8(d) of TSCA, EPA promulgated a model Health and Safety Data Reporting Rule. The section 8(d) model rule requires manufacturers, importers, and processors of listed chemical substances and mixtures to submit to EPA copies and lists of unpublished health and safety studies. Dichloromonofluoromethane is included on this list. Effective date: 4/13/89; Sunset date: 12/19/95.

Safety data

OEB
A
OEL
TWA: 10 ppm (40 mg/m3)
IDLA
5,000 ppm
tsca
TSCA listed
rtecs
PA8400000
ridadr
UN 1029 (DICHLOROFLUOROMETHANE (REFRIGERANT GAS R 21))
Toxicity
LC50 (inhalation) for rats 49,900 ppm/4-h (quoted, RTECS, 1985).
risk_code
59
Signal word
Danger
Symbol(GHS)
GHS04
hazard_code
N
safety_code
59
hazard_class
2.2
Hazard statements
H280
Precautionary statements
P410+P403
Hazardous Substances Data
75-43-4(Hazardous Substances Data)
U.S. ProductionProduction volume for non-confidential chemicals reported under the 2006 Inventory Update Rule. Chemical: Methane, dichlorofluoro-. Aggregated National Production Volume: < 500,000 pounds.
Consumption Patterns · 2 items

REFRIGERANTS, 39%; FOAM BLOWING AGENTS, 14%; SOLVENTS, 14%; FLUOROPOLYMERS, 14%; STERILANT GAS, 2%; AEROSOL PROPELLANTS, 2%; FOOD FREEZANT, 1%; OTHER, 8%; EXPORTS, 3% (1985) /FLUOROCARBONS/

Refrigeration/air conditioning, 43%; foam blowing agents, 20%; polymer precursors, 13%; solvent cleaning, 12%; aerosol propellants, 2%; medical equipment sterilization, 3%; other, 7% /Fluorocarbons/

Methods of Manufacturing · 2 items

Reaction of chloroform and hydrogen fluoride.

The most important commercial method for manufacturing /chlorofluoro carbons/ is the successive replacement of chlorine by fluorine using hydrogen fluoride ... CHCl2F /Freon 21/ is produced by reacting chloroform with HF

Formulations/PreparationsGrade: Technical
General Manufacturing Information · 2 items

Methane, dichlorofluoro-: ACTIVE

Per 40 CFR 82, which implements the Montreal Protocol, dichlorofluoromethane will no longer be produced or imported in the United States after 2015, except for its use as a refrigerant in equipment manufactured before 1/1/2020; no production or importing after 1/1/2030 will be allowed.

Applications · 4 items

DescriptionDichlorofluoro-methane is a heavy, colorlessgas or liquid (below 9℃) with a slight ether-like odor.Molecular weight=102.92; Boiling point=9℃; Freezing/Melting point=2135℃; Relative vapor density (air-5 1)=3.57; Vapor pressure=1.6 atm at 25℃;Autoignition temperature=522℃. Hazard Identification(based on NFPA-704 M Rating System): Health 1,Flammability 0, Reactivity 0. Poor solubility in water;solubility=0.7% at 30℃.

UsesFire extinguishers; solvent; refrigerant.

UsesRefrigerant gas; propellant gas

General DescriptionDichloromonofluoromethane is a colorless, odorless gas. Dichloromonofluoromethane is shipped as a liquid under its own vapor pressure. Contact with the liquid may cause frostbite to unprotected skin. Dichloromonofluoromethane can asphyxiate by displacement of air. Exposure of the container to prolonged heat or fire may cause Dichloromonofluoromethane to rupture violently and rocket.

Upstream & downstream products

Upstream raw materials

Hydrogen fluorideChlorofluoromethane

Downstream products

2,3,5,6-Tetrafluorobenzotrifluoride1,2-Dichloro-1,2-difluoroethyleneTetrafluoroethylene1,2-Difluorotetrachloroethane