HomeMCPWorkbenchSkills
HomeWorkbenchNotificationsMe
llms.txt · MCP GuidePrivacy Policy · Terms of Service · Supportv1.8.3
  1. Home
  2. /Reaction

2-[Benzyl-(5,6-diethyl-indan-2-yl)-amino]-1-(4-benzyloxy-3-nitro-phenyl)ethanone → 1-(3-Amino-4-benzyloxy-phenyl)-2-[benzyl-(5,6-diethyl-indan-2-yl)-amino]-ethanone

HRID 2089080
Print

Reaction equation

HRID 2089080 reaction equation
[CH2:1]([N:8]([CH:29]1[CH2:37][C:36]2[C:31](=[CH:32][C:33]([CH2:40][CH3:41])=[C:34]([CH2:38][CH3:39])[CH:35]=2)[CH2:30]1)[CH2:9][C:10]([C:12]1[CH:17]=[CH:16][C:15]([O:18][CH2:19][C:20]2[CH:25]=[CH:24][CH:23]=[CH:22][CH:21]=2)=[C:14]([N+:26]([O-])=O)[CH:13]=1)=[O:11])[C:2]1[CH:7]=[CH:6][CH:5]=[CH:4][CH:3]=1.NC1C=C([C@@H](O)CN(CC2C=CC=CC=2)C2CC3C(=CC(CC)=C(CC)C=3)C2)C=CC=1OCC1C=CC=CC=1>>[NH2:26][C:14]1[CH:13]=[C:12]([C:10](=[O:11])[CH2:9][N:8]([CH2:1][C:2]2[CH:3]=[CH:4][CH:5]=[CH:6][CH:7]=2)[CH:29]2[CH2:30][C:31]3[C:36](=[CH:35][C:34]([CH2:38][CH3:39])=[C:33]([CH2:40][CH3:41])[CH:32]=3)[CH2:37]2)[CH:17]=[CH:16][C:15]=1[O:18][CH2:19][C:20]1[CH:21]=[CH:22][CH:23]=[CH:24][CH:25]=1
ParticipantsProcedureWorkupSources & evidenceReaction notes

Participants

3

Reactant 2

HCID 224992192-[Benzyl-(5,6-diethyl-indan-2-yl)-amino]-1-(4-benzyloxy-3-nitro-phenyl)ethanoneHCID 53799063(R)-1-(3-Amino-4-benzyloxy-phenyl)-2-[benzyl-(5,6-diethyl-indan-2-yl)-amino]-ethanol

Product 1

HCID 574942321-(3-Amino-4-benzyloxy-phenyl)-2-[benzyl-(5,6-diethyl-indan-2-yl)-amino]-ethanone

Procedure

1-(3-Amino-4-benzyloxy-phenyl)-2-[benzyl-(5,6-diethyl-indan-2-yl)-amino]-ethanone is prepared from 2-[benzyl-(5,6-diethyl-indan-2-yl)-amino]-1-(4-benzyloxy-3-nitro-phenyl)-ethanone (1.50 g) by an analogous procedure to that used to prepare (R)-1-(3-Amino-4-benzyloxy-phenyl)-2-[benzyl-(5,6-diethyl-indan-2-yl)-amino]-ethanol in Example 19. The reaction is shown to be complete by TLC after 48 hours. The catalyst is filtered off and the solvent is removed in vacuo. The product is purified by flash column chromatography (silica, n-hexane/ethyl acetate 4:1). TLC (silica, n-hexane/ethyl acetate 2:1 Rf=0.70).

Workup

  1. filtrationThe catalyst is filtered off
  2. customthe solvent is removed in vacuo
  3. customThe product is purified by flash column chromatography (silica, n-hexane/ethyl acetate 4:1)

Sources & evidence

ORD record
ord-8e1456cf3d3d4f3eb305b5185bd22862
Source dataset
uspto-grants-2013_05
DOI
10.6084/m9.figshare.5104873.v1
Patent number
US08436017B2

Reaction notes

On this pageParticipantsProcedureWorkupSources & evidenceReaction notes