亜硝酸プロピル

Propyl nitrite

HCID 10979CAS 543-67-9

基本情報

標準SMILES
CCCON=O
InChIKey
KAOQVXHBVNKNHA-UHFFFAOYSA-N
分子式
C3H7NO2
平均分子量
89.09 g/mol
単同位体質量
89.04767847

名称と識別子

優先名称
Propyl nitrite
IUPAC
propyl nitrite
現地名
亜硝酸プロピル
英語名
n-Propyl nitrite
分子式
C3H7NO2
分子量
89.09

名称と別名

Propyl nitriten-Propyl nitrite543-67-9Nitrous acid, propyl estern-Propyl-nitriteCCRIS 1254n-C3H7ONOUNII-ML3G2M13HZEINECS 208-848-5ML3G2M13HZBRN 16999261-PROPYL NITRITE
名称をさらに表示
亜硝酸プロピルプロピル ニトリットpropanolnitritePropanol nitritenitrousacidpropylesternitrousacid,propylesternitrousacid,n-propylesterNitrous acid, n-propyl ester
PROPYL NITRITE, N-PROPYL NITRITE [MI]DTXSID50752824-01-00-01424 (Beilstein Handbook Reference)RefChem:176505DTXCID2041674208-848-5KAOQVXHBVNKNHA-UHFFFAOYSA-N

データベース識別子

CAS
543-67-9
PubChem CID
10979
DTXSID
DTXSID5075282
UNII
ML3G2M13HZ
EC Number
208-848-5
Nikkaji
J23.979H

物性

構造計算による物性

XLogP
0.9
極性表面積
38.7 Ų
水素結合供与体数
0
水素結合受容体数
3
回転可能結合数
2
重原子数
6

実験および物理化学的性質

Physical DescriptionPropionitrite appears as a colorless liquid with a sweet, ethereal odor. Highly toxic by inhalation and ingestion. A dangerous fire risk. Used as a solvent and as a dielectric fluid.
Kovats Retention Index486

物理化学的性質

沸点
760 · bp760 46-48°
比重(密度)
420 · d420 0.8864
屈折率
20 · nD20 1.3592; nD20 1.3613
EPAの化学物質情報
Nitrous acid, propyl ester (543-67-9)

安全と法規制

GHS分類

GHS Classification · 5 件

Danger

H225 (100%): Highly Flammable liquid and vapor [Danger Flammable liquids];H315 (100%): Causes skin irritation [Warning Skin corrosion/irritation];H319 (100%): Causes serious eye irritation [Warning Serious eye damage/eye irritation];H330 (100%): Fatal if inhaled [Danger Acute toxicity, inhalation];H335 (100%): May cause respiratory irritation [Warning Specific target organ toxicity, single exposure; Respiratory tract irritation]

P210, P233, P240, P241, P242, P243, P260, P261, P264, P264+P265, P271, P280, P284, P302+P352, P303+P361+P353, P304+P340, P305+P351+P338, P316, P319, P320, P321, P332+P317, P337+P317, P362+P364, P370+P378, P403+P233, P403+P235, P405, and P501 (click each P-code to see the statement)

The GHS information provided by 1 company from 1 notification to the ECHA C&L Inventory.

危険有害性情報

DOT LabelFlammable Liquid
Fire Hazards · 1 件

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids will float on water. (ERG, 2024)

Health Hazards · 1 件

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;May cause toxic effects if inhaled or absorbed through skin. Inhalation or contact with material may irritate or burn skin and eyes. Fire will produce irritating, corrosive and/or toxic gases. Vapors may cause dizziness or asphyxiation, especially when in closed or confined areas. Runoff from fire control or dilution water may cause environmental contamination. (ERG, 2024)

Reactive GroupNitro, Nitroso, Nitrate, and Nitrite Compounds, Organic
Reactivity AlertsHighly Flammable;Strong Oxidizing Agent
Reactivity ProfilePROPIONITRITE is an oxidizing agent. If mixed with reducing agents, including hydrides, sulfides and nitrides, may begin a vigorous reaction that culminates in a detonation. Reacts with inorganic bases to form explosive salts.

安全と保護具

Fire Fighting · 1 件

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient.;SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. Do not use dry chemical extinguishers to control fires involving nitromethane (UN1261) or nitroethane (UN2842).;LARGE FIRE: Water spray, fog or alcohol-resistant foam. Avoid aiming straight or solid streams directly onto the product. If it can be done safely, move undamaged containers away from the area around the fire.;FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

First Aid · 1 件

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;Refer to the "General First Aid" section. Specific First Aid: Wash skin with soap and water. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)

Nonfire Spill Response · 1 件

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material.;LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)

Isolation and Evacuation · 1 件

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.;LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).;FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Personal Protective Equipment (PPE) · 1 件

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

化学と産業

応用分野

使用Jet propellant.

一般的な説明A colorless liquid with a sweet, ethereal odor. Highly toxic by inhalation and ingestion. Flash point 61°F. A dangerous fire risk. Used as a solvent and as a dielectric fluid.

上流・下流製品情報

サプライヤー6 社

Dayang Chem (Hangzhou) Co.,Ltd.+86-0571-88938639 17705817739 · [email protected]
卡迪亚医药科技有限公司0371-86615086 18203638366 0371-86159066 13526786601
PT CHEM GROUP LIMITED+86-85511178; +86-85511178 · [email protected]
Shaanxi Didu New Materials Co. Ltd+86-86-17392712779 +86-13289823923 · [email protected]
厦门盈融达化工有限公司+86-0592-6210733 · [email protected]

関連反応

1 件

関連ノート

読み込み中…