Vinylamine

HCID 11642CAS 26336-38-9

基本情報

標準SMILES
C=CN
InChIKey
UYMKPFRHYYNDTL-UHFFFAOYSA-N
分子式
C2H5N
平均分子量
43.07 g/mol
単同位体質量
43.04219916

名称と識別子

優先名称
Vinylamine
IUPAC
ethenamine
英語名
POLY(VINYLAMINE) HYDROCHLORIDE
分子式
C2H5N
分子量
43.07

名称と別名

EthenamineVINYLAMINEEthyleneamineethenylamineEINECS 209-802-7UNII-B57U1A0H6FBRN 1900280B57U1A0H6FDTXSID2075053Ethenamine (9CI)ETHYLENE AMINESRefChem:194330
名称をさらに表示
PVAmpoly(vinylamine)PEG-PVAmPoly(vinylamine)HClPolyethylenpolyaminePoly(N-ethenylamine)Ethenamine,homopolymerPOLY(VINYLAMINE) HYDROCHLORIDEpolyvinyl amine HCl (MW: ~25,000)Poly(vinylamine) hydrochloride, average Mw 25000
DTXCID4042597209-802-7Aminoethylene593-67-9EthylenamineN-vinylamineEthenamine homopolymerCH2=CHNH2

データベース識別子

CAS
26336-38-9、593-67-9
PubChem CID
11642
DTXSID
DTXSID2075053
UNII
B57U1A0H6F
EC Number
209-802-7
Nikkaji
J136.512F

物性

構造計算による物性

XLogP
0.2
極性表面積
26 Ų
水素結合供与体数
1
水素結合受容体数
1
回転可能結合数
0
重原子数
3

実験および物理化学的性質

Physical DescriptionUsually colorless to light colored liquids with an ammonia-like odor. Flammable. May be very corrosive to skin, eyes, mucus membranes and metals. They are often used as fungicides and to manufacture other chemicals.

物理化学的性質

EPAの化学物質情報
Ethenamine, homopolymer (26336-38-9)

安全と法規制

GHS分類

GHS Classification · 3 件

This chemical does not meet GHS hazard criteria for 100% (36 of 36) of all reports.

Not Classified;Reported as not meeting GHS hazard criteria by 36 of 36 companies. For more detailed information, please visit ECHA C&L website.

Aggregated GHS information provided per 36 reports by companies from 1 notifications to the ECHA C&L Inventory.;Reported as not meeting GHS hazard criteria per 36 of 36 reports by companies.;There are 0 notifications provided by 0 of 36 reports by companies with hazard statement code(s).;Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

危険有害性情報

DOT LabelFlammable Liquid Corrosive
Fire Hazards · 1 件

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:;Flammable/combustible material. May be ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids will float on water. (ERG, 2024)

Health Hazards · 1 件

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:;May cause toxic effects if inhaled or ingested. Contact with substance may cause severe burns to skin and eyes. Fire will produce irritating, corrosive and/or toxic gases. Vapors may cause dizziness or asphyxiation, especially when in closed or confined areas. Runoff from fire control or dilution water may cause environmental contamination. (ERG, 2024)

Reactive GroupAmines, Phosphines, and Pyridines;Hydrocarbons, Aliphatic Unsaturated
Reactivity AlertsHighly Flammable
Reactivity Profile · 1 件

React violently with acids, strong oxidants and halogens; attack copper, aluminum, zinc and their alloys; react with mercury and silver oxides to form shock sensitive compounds. [Handling Chemicals Safely 1980. p. 139]; reacts with hypochlorites to give N-chloroamines, some of which, are explosives when isolated [Bretherick 1979. p. 108].

安全と保護具

Fire Fighting · 1 件

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:;Some of these materials may react violently with water.;SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam.;LARGE FIRE: Water spray, fog or alcohol-resistant foam. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal. Do not get water inside containers.;FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

First Aid · 1 件

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:;Refer to the "General First Aid" section. Specific First Aid: For corrosives, in case of contact, immediately flush skin or eyes with running water for at least 30 minutes. Additional flushing may be required. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)

Nonfire Spill Response · 1 件

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:;ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb with earth, sand or other non-combustible material. For hydrazine, absorb with DRY sand or inert absorbent (vermiculite or absorbent pads). Use clean, non-sparking tools to collect absorbed material.;LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)

Isolation and Evacuation · 1 件

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:;IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.;SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.;FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Personal Protective Equipment (PPE) · 1 件

Excerpt from ERG Guide 132 [Flammable Liquids - Corrosive]:;Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)

安全データ

tsca
TSCA listed

化学と産業

サプライヤー1 社

Shaanxi Didu New Materials Co. Ltd+86-86-17392712779 +86-13289823923 · [email protected]

関連反応

1 件

関連ノート

読み込み中…