ホームMCPワークベンチSkills
ホームワークベンチ通知マイページ
化工社オープンプロジェクト:[email protected]AIアクセス:llms.txt · MCPガイドプライバシーポリシー · 利用規約 · サポートv1.7.8
  1. ホーム
  2. /化合物

クロム酸二リチウム

Lithium chromate

HCID 26627
ノート反応
基本情報概要名称と識別子物性安全と法規制化学と産業関連反応化合物ノート
部分構造検索類似構造を探す

基本情報

CAS
14307-35-8
標準SMILES
[Li+].[Li+].[O]=[Cr](=[O])([O-])[O-]
InChIKey
JQVALDCWTQRVQE-UHFFFAOYSA-N
分子式
Li2CrO4
平均分子量
129.9 g/mol
単同位体質量
129.95217

概要

Lithium chromate appears as a yellow crystalline solid. The primary hazard is the threat to the environment. Immediate steps should be taken to limit its spread to the environment. It is used as a corrosion inhibitor and in the manufacture of other chemicals.

名称と識別子

優先名称
Lithium chromate
IUPAC
dilithium;dioxido(dioxo)chromium
現地名
クロム酸二リチウム
英語名
Lithium chromate
分子式
CrLi2O4
分子量
129.8757

名称と別名

LITHIUM CHROMATE14307-35-8Lithium chromate(VI)Dilithium chromateChromium lithium oxide (CrLi2O4)Lithium chromium oxide (Li2CrO4)Chromic acid, dilithium saltLithium chromate (Li2CrO4)Dilithium chromate (Li2CrO4)dilithium;dioxido(dioxo)chromiumChromic acid (H2CrO4), dilithium salt5UR77B9Q8M
名称をさらに表示
クロム酸二リチウムクロム酸リチウムリチウム クロム酸二クロム酸リチウムジオキソ-2,4-ジオキサ-3-クロマ-1,5-ジリタペンタンLithiumchromatchroman dilitnydilithiumchromatelithiumchromate(vi)chromiumlithiumoxidelithium chromium oxideLithiumchromate,min.95%lithiumchromate(li2cro4)Chromicacid,dilithiumsalt
Chromic acid (H2CrO4) lithium salt (1:2)MFCD00016175HSDB 650EINECS 238-244-7UNII-5UR77B9Q8MLithium chromate, min. 95%SCHEMBL225985dilithium,dioxido(dioxo)chromium

物性

構造計算による物性

極性表面積
80.3 Ų
水素結合供与体数
0
水素結合受容体数
4
回転可能結合数
0
重原子数
7
形式電荷
0
複雑度
62.2

実験および物理化学的性質

Chemical Classes · 2 件

Metals -> Chromium Compounds, Inorganic

Carcinogens

pH... hexavalent chromium compounds are acidic
OdorOdorless
Density · 3 件

2.15 - 2.426 g/cu cm

Density: 2.15 g/cu cm /Lithium chromate dihydrate/

2.15 @25 °C

Color/FormYellow crystalline powder
Solubility · 4 件

Solubility: 48.6 wt% at 20 °C /Lithium chromate dihydrate/

111 g/100 g water at 20 °C

The anhydrous salt is appreciably soluble in methanol and ethanol

Sol in water

Physical Description · 2 件

Lithium chromate appears as a yellow crystalline solid. The primary hazard is the threat to the environment. Immediate steps should be taken to limit its spread to the environment. It is used as a corrosion inhibitor and in the manufacture of other chemicals.

Dihydrate: Yellow deliquescent solid; Very soluble in water; [Merck Index] Yellow crystals; Soluble in water; [MSDSonline]

Autoignition TemperatureNot flammable (USCG, 1999)
Other Experimental Properties

安全と法規制

安全情報は参考情報です。供給元の安全データシート(SDS)、適用法令、専門家による評価に代わるものではありません。

GHS分類

GHS Classification · 6 件

Danger

H301 (38.2%): Toxic if swallowed [Danger Acute toxicity, oral]

P203, P233, P260, P261, P264, P270, P271, P272, P273, P280, P284, P301+P316, P302+P352, P304+P340, P316, P317, P318, P319, P320, P321, P330, P333+P317, P342+P316, P362+P364, P391, P403, P403+P233, P405, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 68 reports by companies from 5 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Danger

H301: Toxic if swallowed [Danger Acute toxicity, oral]

危険有害性情報

Regulatory Information · 3 件

Chemical: Chromic acid (H2CrO4), dilithium salt

Chromic acid (H2CrO4), dilithium salt: Does not have an individual approval but may be used as a component in a product covered by a group standard. It is not approved for use as a chemical in its own right.

The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)

Other Safety InformationIMAP assessments - Chromates and dichromates (soluble): Human health tier II assessment
Health Hazards · 1 件

INHALATION: Corrosive to skin and mucous membranes causing dermatitis and slow healing ulcers. EYES: Conjunctivitis and lacrimation. INGESTION: Violent gastroenteritis, peripheral vascular collapse, vertigo, muscle cramps, coma, hemorrhagic diathesis, fever, liver damage and renal failure. (USCG, 1999)

Hazards SummaryA strong oxidizing agent; Corrosive effects to skin and mucous membranes; Causes lacrimation; Ingestion can cause damage to liver and kidneys; [CAMEO] See Lithium. See Chromium and linked occupational diseases.
Reactive Group

化学と産業

薬理情報

Metabolism/Metabolites · 1 件

Chromium is absorbed from oral, inhalation, or dermal exposure and distributes to nearly all tissues, with the highest concentrations found in kidney and liver. Bone is also a major storage site and may contribute to long-term retention. Hexavalent chromium's similarity to sulfate and chromate allow it to be transported into cells via sulfate transport mechanisms. Inside the cell, hexavalent chromium is reduced first to pentavalent chromium, then to trivalent chromium by many substances including ascorbate, glutathione, and nicotinamide adenine dinucleotide. Chromium is almost entirely excreted with the urine. (A12, L16)

用途と製造

Uses · 4 件

Used as a corrosion inhibitor (water cooled atomic reactors, air conditioners, and antifreezes), low-temperature heat transfer medium, and oxidizing agent; [HSDB]

Corrosion inhibitor for water-cooled atomic reactors. Solution as low temperature heat transfer medium.

Corrosion inhibitor in alcohol-base antifreezes and water-cooled reactors. Oxidizing agent for organic material, especially in the presence of light; heat-transfer medium

... used as a corrosion inhibitor in air conditioners that contain lithium chloride or bromide solutions.

Methods of ManufacturingIt is made from lithium hydroxide and chromic acid.
Formulations/Preparations35% solution grade
General Manufacturing Information · 2 件

Chromic acid (H2CrO4), lithium salt (1:2): ACTIVE

During reduction of lithium chromate at 450-600 °C, a considerable excess of zirconium must be used to avoid an explosion.

応用分野 · 2 件

使用Lithium Chromate is used in preparation method method of permeable crystalline cement-based waterproof coating by using maifanstone composite high water-absorbing resin and its application in building.

関連反応

0 件
反応記録を作成

現在のフィルター条件では反応記録がありません。

化合物ノート

読み込み中…

このページの内容基本情報概要名称と識別子物性安全と法規制化学と産業関連反応化合物ノート

データベース識別子

CAS
14307-35-8
PubChem CID
26627
DTXSID
DTXSID8065749
UNII
5UR77B9Q8M
EC Number
238-244-7
· 5 件

Lithium chromate is an oxidizing agent. Can oxidize combustibles. Combining the chromate with zirconium can be explosive given the right proportions of reactants.

Yellow crystal powder. Deliquescent; becomes anhydrous at 74.6 °C; very soluble in water /Lithium chromate dihydrate/

Eutectic with water below -60 °C

Decomposes at 75 °C /Lithium chromate dihydrate/

Soluble in water and in alcohols /Lithium chromate dihydrate/

物理化学的性質

融点
844 ℃ · 844℃
比重(密度)
1.355 · 1.355
外見
結晶
色
黄色
水溶解度
25 ℃で94.6g/L · 25℃で94.6g/L
InChI
InChI=1S/Cr.2Li.4O/q;2*+1;;;2*-1
InChIKey
JQVALDCWTQRVQE-UHFFFAOYSA-N
SMILES
[Cr](=O)(=O)([O-])[O-].[Li+].[Li+]
CAS データベース
14307 · 14307-35-8(CAS DataBase Reference)
EPAの化学物質情報
Lithium chromate (14307-35-8)

化学的性質

化学的特性Lithium chromate is a yellow or orange-yellow crystalline powder. It dissolves in strong acids and alkalis but is insoluble in water and oil. It is made from lithium hydroxide and chromic acid.

Salts, Basic
Special ReportsDHHS/ATSDR; Toxicological profile for chromium (September 2012).[DHHS/ATSDR; Toxicological profile for chromium (September 2012); Available from, as of February 8, 2016: ww.atsdr.cdc.gov/toxprofiles/tp7.pdf]
RCRA Requirements · 1 件

D007; A solid waste containing chromium may or may not become characterized as a hazardous waste when subjected to the Toxicity Characteristic Leaching Procedure listed in 40 CFR 261.24, and if so characterized, must be managed as a hazardous waste. /Chromium/

Reactivity AlertsStrong Oxidizing Agent
OSHA Standards · 4 件

Permissible Exposure Limit: Table Z-1 8-hr Time Weighted Avg: 1 mg/cu m. /Chromium metal and insoluble salts, as Cr/

Permissible Exposure Limit: Table Z-1 8-hr Time Weighted Avg: 0.5 mg/cu m. /Chromium(II) compounds, as Cr/

Permissible Exposure Limit: Table Z-1 8-hr Time Weighted Avg: 0.5 mg/cu m. /Chromium(III) compounds, as Cr/

Permissible Exposure Limit: Table Z-2 Acceptable Ceiling Concentration: 1 mg/10 cu m. /Chromic acid and chromates (as CrO3)/

Reactivity ProfileLITHIUM CHROMATE is an oxidizing agent. Can oxidize combustibles (USCG, 1999). Combining the chromate with zirconium can be explosive given the right proportions of reactants, [Z. Anorg., 1930, 191, 113].
Atmospheric Standards · 2 件

... Substances for which a Federal Register notice has been published that included consideration of the serious health effects, including cancer, from ambient air exposure to the substance. Chromium is included on this list. /Chromium/

Listed as a hazardous air pollutant (HAP) generally known or suspected to cause serious health problems. The Clean Air Act, as amended in 1990, directs EPA to set standards requiring major sources to sharply reduce routine emissions of toxic pollutants. EPA is required to establish and phase in specific performance based standards for all air emission sources that emit one or more of the listed pollutants. Chromium compounds is included on this list. /Chromium compounds/

Air and Water ReactionsDeliquescent. Water soluble

安全と保護具

First AidCall a doctor.
Exposure Control and Personal Protection0.2 [mg/m3], inhalable fraction, as Li[German Research Foundation (DFG)]
Fire Fighting Procedures · 5 件

If material involved in fire: Extinguish fire using agent suitable for type of surrounding fire (Material itself does not burn or burns with difficulty.)

Use extinguising agents suitable for surrounding fire.

Containers may explode in a fire. From a secure, explosion-proof location, use water spray to cool exposed containers. If cooling streams are ineffective venting sound increases in volume and pitch, tank discolors, or shows any signs of deforming), withdraw immediately to a secure position.

The only respirators recomended for firefighting are self-contained breathing apparatuses that have full face-pieces and are operated in a pressure-demand or other positive-pressure mode.

/When fire fighting wear/ self-contained breathing apparatus, with a full facepiece, operated in pressure-demand or other positive pressure mode. /Chromic acid & chromates/

Storage Conditions · 1 件

Store in a secure poison location. Prior to working with this chemical you should be trained on its proper handling and storage. A regulated, marked area should be established where this chemical is handled, used, or stored in compliance with OSHA Standard 1910.1045. Store in tightly closed containers in a cool, well-ventilated area away from acids, hydrazine, chromic acid, combustible materials, sulfur, aluminum, plastics, and reducing agents.

Cleanup Methods · 5 件

Environmental considerations: Land Spill: Dig a pit, pond, lagoon, holding area to contain liquid or solid material. /SRP: If time permits, pits, ponds, lagoons, soak holes, or holding areas should be sealed with an impermeable flexible membrane liner./ Cover solids with a plastic sheet to prevent dissolving in rain or fire fighting water.

Environmental considerations: Water Spill: Neutralize with agricultural lime (CaO), crushed limestone (CaCO3), or sodium bicarbonate (NaHCO3). Add soda ash (NaCo3). Adjust pH to neutral (pH=7).

Spill handling: Evacuate persons not wearing protective equipment from area of spill or leak until cleanup is complete. Remove all ignition sources. Collect powdered material in the most convenient and safe manner and deposit in sealed containers. Ventilate area after cleanup is complete. It may be necessary to contain and dispose of this chemical as a hazardous waste. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters.

Cr(VI) cmpd in waste sludge are completely removed by redn by carbon at 600 °C. /Chromium VI/

Persons not wearing protective equipment and clothing should be restricted from areas of spills until cleanup has been completed. If chromic acid or chromates are spilled, the following steps should be taken: 1. Ventilate area of spill. 2. Collect spilled material in the most convenient and safe manner and deposit in sealed containers for reclamation or for disposal in a secured sanitary landfill. Liquid containing chromic acid or chromates should be absorbed in vermiculite, dry sand, earth, or a similar material. /Chromic acid and chromates/

Disposal Methods · 5 件

Generators of waste (equal to or greater than 100 kg/mo) containing this contaminant, EPA hazardous waste number D007, must conform with USEPA regulations in storage, transportation, treatment and disposal of waste. /Chromium/

SRP: Wastewater from contaminant suppression, cleaning of protective clothing/equipment, or contaminated sites should be contained and evaluated for subject chemical or decomposition product concentrations. Concentrations shall be lower than applicable environmental discharge or disposal criteria. Alternatively, pretreatment and/or discharge to a permitted wastewater treatment facility is acceptable only after review by the governing authority and assurance that "pass through" violations will not occur. Due consideration shall be given to remediation worker exposure (inhalation, dermal and ingestion) as well as fate during treatment, transfer and disposal. If it is not practicable to manage the chemical in this fashion, it must be evaluated in accordance with EPA 40 CFR Part 261, specifically Subpart B, in order to determine the appropriate local, state and federal requirements for disposal.

The following wastewater treatment technology has been investigated for chromium: Concentration process: Biological Treatment. /Chromium/

The following wastewater treatment technology has been investigated for chromium: Concentration process: Chemical Precipitation. /Chromium/

For more Disposal Methods (Complete) data for LITHIUM CHROMATE (9 total), please visit the HSDB record page.

Preventive Measures · 5 件

SRP: The scientific literature for the use of contact lenses by industrial workers is inconsistent. The benefits or detrimental effects of wearing contact lenses depend not only upon the substance, but also on factors including the form of the substance, characteristics and duration of the exposure, the uses of other eye protection equipment, and the hygiene of the lenses. However, there may be individual substances whose irritating or corrosive properties are such that the wearing of contact lenses would be harmful to the eye. In those specific cases, contact lenses should not be worn. In any event, the usual eye protection equipment should be worn even when contact lenses are in place.

If material not involved in fire: Keep material out of water sources and sewers. Build dikes to contain flow as necessary.

Personnel protection: Keep upwind. ... Avoid breathing vapors or dusts. Wash away any material which may have contacted the body with copious amounts of water or soap and water.

SRP: Contaminated protective clothing should be segregated in a manner such that there is no direct personal contact by personnel who handle, dispose, or clean the clothing. The completeness of the cleaning procedures should be considered before the decontaminated protective clothing is returned for reuse by the workers. Contaminated clothing should not be taken home at the end of shift, but should remain at employee's place of work for cleaning.

For more Preventive Measures (Complete) data for LITHIUM CHROMATE (7 total), please visit the HSDB record page.

Minimum Risk LevelIntermediate Oral: 0.005 mg/kg/day (L134) Chronic Oral: 0.001 mg/kg/day (L134)
Threshold Limit Values (TLV) · 6 件

0.0001 [mg/m3], as Cr(VI), inhalable particulate matter

0.0005 [mg/m3], as Cr(VI), inhalable particulate matter

8 hr Time Weighted Avg (TWA): 0.5 mg/cu m. /Chromium and Cr(III) inorganic compounds, as Cr/

A4; Not classifiable as a human carcinogen. /Chromium and Cr(III) inorganic compounds, as Cr/

Peak Exposure Recommendation: Transient increases in workers' exposure levels may exceed 3 times the value of the TLV-TWA level for no more than 15 minutes at a time, on no more than 4 occasions spaced 1 hour apart during a workday, and under no circumstances should they exceed 5 times the value of the TLV-TWA level. In addition, the 8-hour TWA is not to be exceeded for an 8-hour work period. /Chromium and Cr(III) inorganic compounds, as Cr/

8 Hr Time Weighted Avg (TWA): 0.05 mg/cu m. /Water-soluble Cr(VI) inorganic compounds, as Cr/

Permissible Exposure Limit (PEL)0.005 [mg/m3], as Cr(VI)
Protective Action Criteria (PAC) · 3 件

0.00065 [mg/m3]

6.5 [mg/m3]

39 [mg/m3]

Personal Protective Equipment (PPE) · 6 件

Approved filter-type respirator, close-fitting safety goggles, laboratory coat. (USCG, 1999)

Wear protective gloves and clothing to prevent any reasonable probability of skin contact.

Wear dust-proof chemical goggles and face shield unless full face-piece respiratory protection is worn.

Employees should wash immediately with soap when skin is wet or contaminates. Provide emergency showers and eyewash.

Impervious gloves, aprons, and footwear shall be worn at operations where solutions of chromium (VI) may contact the skin. Protective gloves shall be worn at operations where dry compounds of chromium (VI) are handled and may contact the skin. /Cr(VI)/

For more Personal Protective Equipment (PPE) (Complete) data for LITHIUM CHROMATE (11 total), please visit the HSDB record page.

毒性情報

TreatmentThere is no know antidote for chromium poisoning. Exposure is usually handled with symptomatic treatment. (L16)
Health EffectsHexavalent chromium is a known carcinogen. Chronic inhalation especially has been linked to lung cancer. Hexavalent chromium has also been know to cause reproductive and developmental defects. (A12)
Adverse EffectsNeurotoxin - Other CNS neurotoxin
Exposure RoutesInhalation (L16) ; oral (L16) ; dermal (L16)
Toxicity Summary · 2 件

IDENTIFICATION AND USE: Lithium chromate is a yellow crystalline powder. It is used as corrosion inhibitor in alcohol-based antifreezes and water-cooled reactors. It is also used as oxidizing agent for organic material, especially in the presence of light; heat-transfer medium. HUMAN EXPOSURE AND TOXICITY: There is no data available. ANIMAL STUDIES: There is no data available.

Hexavalent chromium's carcinogenic effects are caused by its metabolites, pentavalent and trivalent chromium. The DNA damage may be caused by hydroxyl radicals produced during reoxidation of pentavalent chromium by hydrogen peroxide molecules present in the cell. Trivalent chromium may also form complexes with peptides, proteins, and DNA, resulting in DNA-protein crosslinks, DNA strand breaks, DNA-DNA interstrand crosslinks, chromium-DNA adducts, chromosomal aberrations and alterations in cellular signaling pathways. It has been shown to induce carcinogenesis by overstimulating cellular regulatory pathways and increasing peroxide levels by activating certain mitogen-activated protein kinases. It can also cause transcriptional repression by cross-linking histone deacetylase 1-DNA methyltransferase 1 complexes to CYP1A1 promoter chromatin, inhibiting histone modification. Chromium may increase its own toxicity by modifying metal regulatory transcription factor 1, causing the inhibition of zinc-induced metallothionein transcription. (A12, L16, A34, A35, A36)

Signs and Symptoms · 1 件

Breathing hexavalent chromium can cause irritation to the lining of the nose, nose ulcers, runny nose, and breathing problems, such as asthma, cough, shortness of breath, or wheezing. Ingestion of hexavalent chromium causes irritation and ulcers in the stomach and small intestine, as well as anemia. Skin contact can cause skin ulcers. (L16)

Carcinogen Classification1, carcinogenic to humans. (L135)
Evidence for Carcinogenicity · 5 件

WEIGHT OF EVIDENCE CHARACTERIZATION: Under the current guidelines (1986), Cr(VI) is classified as Group A - known human carcinogen by the inhalation route of exposure. Carcinogenicity by the oral route of exposure cannot be determined and is classified as Group D. Under the proposed guidelines (1996), Cr(VI) would be characterized as a known human carcinogen by the inhalation route of exposure on the following basis. Hexavalent chromium is known to be carcinogenic in humans by the inhalation route of exposure. Results of occupational epidemiological studies of chromium-exposed workers are consistent across investigators and study populations. Dose-response relationships have been established for chromium exposure and lung cancer. Chromium-exposed workers are exposed to both Cr(III) and Cr(VI) compounds. Because only Cr(VI) has been found to be carcinogenic in animal studies, however, it was concluded that only Cr(VI) should be classified as a human carcinogen. Animal data are consistent with the human carcinogenicity data on hexavalent chromium. Hexavalent chromium compounds are carcinogenic in animal bioassays, producing the following tumor types: intramuscular injection site tumors in rats and mice, intrapleural implant site tumors for various Cr(VI) compounds in rats, intrabronchial implantation site tumors for various Cr(VI) compounds in rats and subcutaneous injection site sarcomas in rats. In vitro data are suggestive of a potential mode of action for hexavalent chromium carcinogenesis. Hexavalent chromium carcinogenesis may result from the formation of mutagenic oxidatitive DNA lesions following intracellular reduction to the trivalent form. Cr(VI) readily passes through cell membranes and is rapidly reduced intracellularly to generate reactive Cr(V) and Cr(IV) intermediates and reactive oxygen species. A number of potentially mutagenic DNA lesions are formed during the reduction of Cr(VI). Hexavalent chromium is mutagenic in bacterial assays, yeasts and V79 cells, and Cr(VI) compounds decrease the fidelity of DNA synthesis in vitro and produce unscheduled DNA synthesis as a consequence of DNA damage. Chromate has been shown to transform both primary cells and cell lines. HUMAN CARCINOGENICITY DATA: Occupational exposure to chromium compounds has been studied in the chromate production, chromeplating and chrome pigment, ferrochromium production, gold mining, leather tanning and chrome alloy production industries. Workers in the chromate industry are exposed to both trivalent and hexavalent compounds of chromium. Epidemiological studies of chromate production plants in Japan, Great Britain, West Germany, and the United States have revealed a correlation between occupational exposure to chromium and lung cancer, but the specific form of chromium responsible for the induction of cancer was not identified ... Studies of chrome pigment workers have consistently demonstrated an association between occupational chromium exposure (primarily Cr(VI)) and lung cancer. Several studies of the chromeplating industry have demonstrated a positive relationship between cancer and exposure to chromium compounds. ANIMAL CARCINOGENICITY DATA: Animal data are consistent with the findings of human epidemiological studies of hexavalent chromium ... /Chromium (VI)/

Antidote and Emergency Treatment · 5 件

Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR if necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Lithium and Related Compounds/

Basic treatment: Establish a patent airway (oropharyngeal or nasopharyngeal airay, if needed). Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary ... . Monitor for shock and treat if necessary ... . Anticipate seizures and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with 0.9% saline (NS) during treatment ... . Do not use emetics. For ingestion, rinse mouth and administer 5 mL/kg up to 200 mL of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool ... . Cover skin burns with dry sterile dressings after decontamination ... . /Lithium and Related Compounds/

Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious, has severe pulmonary edema, or is in severe respiratory distress. Positive-pressure ventilation techniques with a bag-valve-mask device may be beneficial. Consider drug therapy for pulmonary edema ... . Monitor cardiac rhythm and treat arrhythmias if necessary ... . Start IV administration of D5W TKO. Use 0.9% saline (NS) or lactated Ringer's (LR) if signs of hypovolemia are present. For hypotension with signs of hypovolemia, administer fluid cautiously. Consider vasopressors if patient is hypotensive with a normal fluid volume. Watch for signs of fluid overload ... . Treat seizures with diazepam (Valium) or lorazepam (Ativan) ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Lithium and Related Compounds/

/SRP:/ Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Inorganic acids and related compounds/

For more Antidote and Emergency Treatment (Complete) data for LITHIUM CHROMATE (6 total), please visit the HSDB record page.

法規制情報

RCRA Requirements · 1 件

D007; A solid waste containing chromium may or may not become characterized as a hazardous waste when subjected to the Toxicity Characteristic Leaching Procedure listed in 40 CFR 261.24, and if so characterized, must be managed as a hazardous waste. /Chromium/

Atmospheric Standards · 2 件

... Substances for which a Federal Register notice has been published that included consideration of the serious health effects, including cancer, from ambient air exposure to the substance. Chromium is included on this list. /Chromium/

Listed as a hazardous air pollutant (HAP) generally known or suspected to cause serious health problems. The Clean Air Act, as amended in 1990, directs EPA to set standards requiring major sources to sharply reduce routine emissions of toxic pollutants. EPA is required to establish and phase in specific performance based standards for all air emission sources that emit one or more of the listed pollutants. Chromium compounds is included on this list. /Chromium compounds/

CERCLA Reportable Quantities · 1 件

Persons in charge of vessels or facilities are required to notify the National Response Center (NRC) immediately, when there is a release of this designated hazardous substance, in an amount equal to or greater than its reportable quantity of 10 lb or 4.54 kg. The toll free number of the NRC is (800) 424-8802. The rule for determining when notification is required is stated in 40 CFR 302.4 (section IV.D.3.b).

Clean Water Act Requirements · 2 件

Lithium chromate is designated as a hazardous substance under section 311(b)(2)(A) of the Federal Water Pollution Control Act and further regulated by the Clean Water Act Amendments of 1977 and 1978. These regulations apply to discharges of this substance. This designation includes any isomers and hydrates, as well as any solutions and mixtures containing this substance.

Toxic pollutant designated pursuant to section 307(a)(1) of the Federal Water Pollution Control Act and is subject to effluent limitations. /Chromium and compounds/

State Drinking Water Standards(CA) CALIFORNIA 10 ug/L /Hexavalent Chromium/
State Drinking Water Guidelines(ME) MAINE 35 ug/L /Cr VI)
Federal Drinking Water StandardsMaximum contaminant level for inorganic contaminants: Contaminant: Chromium; MCL 0.1 mg/L. /Chromium/
Federal Drinking Water GuidelinesMaximum contaminant level goal for inorganic contaminants: Contaminant: Chromium; MCLG 0.1 mg/L. /Chromium/

安全データ

tsca
TSCA listed
ridadr
1479
risk_code
8-43-49-50/53
hazard_code
T,N
safety_code
17-36/37/39-53-60-61-45
hazard_class
6.1(b)
packing_group
III
特定化学物質
特38-309
有毒物質データの
14307-35-8(Hazardous Substances Data)

一般的な説明Lithium chromate appears as a yellow crystalline solid. The primary hazard is the threat to the environment. Immediate steps should be taken to limit its spread to the environment. It is used as a corrosion inhibitor and in the manufacture of other chemicals.

調製方法

製造方法According to the following equations, Li2CrO4 is formed on boiling a solution of (NH4)2Cr2O7 with LiOH.

上流・下流製品情報

上流原料

リチウムヒドロキシド

サプライヤー56 社

江西益众化工有限公司15307925109 15350027073 · [email protected]
Hebei Chuanghai Biotechnology Co., Ltd+86-17732866630 · [email protected]
山东泰诚生物科技有限公司18769832557 18769832557 · [email protected]
苏州市森菲达化工有限公司18796480002 18796480002 · [email protected]
Anhui Xunrui Chemical Co., Ltd+86-18130097396 · [email protected]
陕西缔都化学有限公司029-029-81123119 17391733320 · [email protected]
上海欧金实业有限公司13564718081 13564718081 · [email protected]
Dayang Chem (Hangzhou) Co.,Ltd.+86-0571-88938639 17705817739 · [email protected]
上海迈瑞尔生化科技有限公司4006356688 18621169109 · [email protected]
安耐吉化学&3A(安徽泽升科技股份有限公司)400-0056266 · [email protected]
梯希爱(上海)化工贸易有限公司021-61109150 · [email protected]
湖北晟威新材料有限公司15207170057 15207170057 · [email protected]
山东多聚化学有限公司0531-88779566 13105315100 · [email protected]
石家庄建鑫生物科技有限公司0311-1906231-3169 19062313169 · [email protected]
四川库利南科技有限公司400-1166-196 18981987031 · [email protected]
艾科试剂4008-755-333 18080918076 · [email protected]
湖北晟威新材料有限公司15207119892 15207119892 · [email protected]
重庆星灿医药科技有限公司13594048950 19923294409 · [email protected]
青岛海智微元生物科技有限公司18317699790 18317699790 · [email protected]
上海兴鲁化工科技有限公司02120970332 · [email protected]
长沙晶康新材料科技有限公司0731-85118349 18874718518 · [email protected]
桦特昇生物科技(武汉)有限公司027-59207879 1972026995 18140587686 · [email protected]
湖北军瑞生物科技有限公司13971166412 · [email protected]
南京艾比克斯生化科技有限公司025-87193546 18652950785 · [email protected]
南通市苏北化工原料有限公司0513-85290972 18762756250 · [email protected]
济南杰森药业有限公司0531-82956131 15069164249 · [email protected]
上海紫一试剂厂4001650900 · [email protected]
武汉弘德悦欣医药科技有限公司027-83850116 18164090116 · [email protected]
巴师傅(上海)生物医药科技有限公司60662071 18117346937 · [email protected]
杭州洁汉化工有限公司+86-571-86217390; +8618058761490 · [email protected]
河南天孚化工有限公司+86-0371-55170693 +86-19937530512 · [email protected]
厦门盈融达化工有限公司+86-0592-6210733 · [email protected]
career henan chemical co+86-0371-86658258 · [email protected]
上海比客新材料科技有限公司021-34790086 17317635738 · [email protected]
海蔚化学86-21-51086038 · [email protected]
常州新星联生物科技有限公司+86-0519-85551759 · [email protected]
上海允复纳米科技有限公司18964169089 · [email protected]
武汉麟盛科技有限公司18162769939 · [email protected]
爆牛贸易重庆有限公司+86-023-6139-8061 +86-86-13650506873 · [email protected]
XIAMEN AMITY INDUSTRY AND TRADE CO., LTD.+8618950047208 · [email protected]
SUZHOU SENFEIDA CHEMICAL CO.,LTD+86-0512-83500002 +86-15195660023 · [email protected]
上海楷森生物科技有限公司17558870519 · [email protected]
山东滨晨化工有限公司13837799094 18351216136 · [email protected]
北京百灵威科技有限公司18210857532 18210857532 · [email protected]
江西浩硕化工有限公司15307027737 15347922863 · [email protected]
Hefei TNJ Chemical Industry Co.,Ltd.+86-0551-65418671 +86-189 4982 3763 · [email protected]
宝鸡福诺康实业有限公司0917-3236817 13220096790 · [email protected]
嘉恒(临沂)化工有限公司18351216136 15866994906 · [email protected]
湖北鑫红利化工有限公司027-027-59106151 15172325309 · [email protected]
深圳利斯康医药科技有限公司+86-0755-89396905 +86-18025329037 · [email protected]

Evaluation: There is sufficient evidence in humans for the carcinogenicity of chromium(VI) compounds. Chromium(VI) compounds cause cancer of the lung. Also positive associations have been observed between exposure to Chromium(IV) compounds and cancer of the nose and nasal sinuses. There is sufficient evidence in experimental animals for the carcinogenicity of chromium(VI) compounds. Chromium(VI) compounds are carcinogenic to humans (Group 1). /Chromium(VI) compounds/

Chromium Hexavalent Compounds: known to be human carcinogens. /Chromium hexavalent compound/

A1; Confirmed human carcinogen. /Water-soluble Cr(VI) inorganic compounds/

A1; Confirmed human carcinogen. /Insoluble Cr(VI) inorganic compounds/