基本情報
- CAS
431-86-7- 標準SMILES
FC(F)(F)C(Cl)C(F)(F)Cl- InChIKey
XAHBEACGJQDUPF-UHFFFAOYSA-N- 分子式
- C3HCl2F5
- 平均分子量
- 202.93 g/mol
- 単同位体質量
- 201.9375462
名称と識別子
- 優先名称
- 1,2-Dichloro-1,1,3,3,3-pentafluoropropane
- IUPAC
- 1,2-dichloro-1,1,3,3,3-pentafluoropropane
- 現地名
- 1,2-ジクロロ-1,1,3,3,3-ペンタフルオロプロパン
- 英語名
- 1,2-Dichloro-1,1,3,3,3-pentafluoropropane
- 分子式
- C3HCl2F5
- 分子量
- 202.94
名称と別名
名称をさらに表示
データベース識別子
- CAS
431-86-7- PubChem CID
- 61115
- DTXSID
DTXSID0042030- UNII
- FAY2SA21WQ
- Nikkaji
- J1.587.673E
物性
構造計算による物性
- XLogP
- 3.4
- 極性表面積
- 0 Ų
- 水素結合供与体数
- 0
- 水素結合受容体数
- 5
- 回転可能結合数
- 1
- 重原子数
- 10
- 形式電荷
- 0
- 複雑度
- 119
実験および物理化学的性質
物理化学的性質
- 沸点
- 50 °C · 50°C
- 比重(密度)
- 1 · 1,56 g/cm3
- 屈折率
- 1.3208 · 1.3208
- EPAの化学物質情報
- -225 da · HCFC-225da (431-86-7)
安全と法規制
危険有害性情報
Fire Hazards
Excerpt from ERG Guide 171 [Substances (Low to Moderate Hazard)]:;Some may burn but none ignite readily. Containers may explode when heated. Some may be transported hot. For UN3508, Capacitor, asymmetric, be aware of possible short circuiting as this product is transported in a charged state. Polymeric beads, expandable (UN2211) may evolve flammable vapours. (ERG, 2024)
Health Hazards
Excerpt from ERG Guide 171 [Substances (Low to Moderate Hazard)]:;Inhalation of material may be harmful. Contact may cause burns to skin and eyes. Inhalation of Asbestos dust may have a damaging effect on the lungs. Fire may produce irritating, corrosive and/or toxic gases. Some liquids produce vapors that may cause dizziness or asphyxiation. Runoff from fire control or dilution water may cause environmental contamination. (ERG, 2024)
Reactivity Profile
1,2-DICHLORO-1,1,3,3,3-PENTAFLUOROPROPANE is chemically inert in many situations, but can react violently with strong reducing agents such as the very active metals and the active metals. They suffer oxidation with strong oxidizing agents and under extremes of temperature.
安全と保護具
Fire Fighting
Excerpt from ERG Guide 171 [Substances (Low to Moderate Hazard)]:;CAUTION: Fire involving Safety devices (UN3268) and Fire suppressant dispersing devices (UN3559) may have a delayed activation and a risk of hazardous projectiles. Extinguish the fire at a safe distance.;SMALL FIRE: Dry chemical, CO2, water spray or regular foam.;LARGE FIRE: Water spray, fog or regular foam. Do not scatter spilled material with high-pressure water streams. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal.;FIRE INVOLVING TANKS: Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. (ERG, 2024)
Nonfire Spill Response
Excerpt from ERG Guide 171 [Substances (Low to Moderate Hazard)]:;Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent dust cloud. For Asbestos, avoid inhalation of dust. Cover spill with plastic sheet or tarp to minimize spreading. Do not clean up or dispose of, except under supervision of a specialist.;SMALL DRY SPILL: With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.;SMALL SPILL: Pick up with sand or other non-combustible absorbent material and place into containers for later disposal.;LARGE SPILL: Dike far ahead of liquid spill for later disposal. Cover powder spill with plastic sheet or tarp to minimize spreading. Prevent entry into waterways, sewers, basements or confined areas. (ERG, 2024)
Isolation and Evacuation
Excerpt from ERG Guide 171 [Substances (Low to Moderate Hazard)]:;IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.;SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.;FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Personal Protective Equipment (PPE)
Excerpt from ERG Guide 171 [Substances (Low to Moderate Hazard)]:;Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2024)
法規制情報
安全データ
- ridadr
- 3082
- risk_code
- 20/21/22-59
- hazard_code
- Xi
- hazard_note
- Irritant
- safety_code
- 23-36/37/39
- hazard_class
- IRRITANT-HARMFUL, OZONE DEPLETER
化学と産業
応用分野
使用1,2-Dichloro-1,1,3,3,3-pentafluoropropane is a refrigerant used in cooling systems.Environmental toxin on US EPA Toxic Release Inventory list (TRI) list.
一般的な説明Colorless odorless liquid. Nonflammable.
サプライヤー14 社
関連反応
化合物ノート