基本情報
- CAS
8063-77-2- 標準SMILES
O=C=O.O=O- InChIKey
UBAZGMLMVVQSCD-UHFFFAOYSA-N- 分子式
- CO4
- 平均分子量
- 76.01 g/mol
- 単同位体質量
- 75.97965848
名称と識別子
- 優先名称
- Carbon dioxide-oxygen mixt.
- IUPAC
- carbon dioxide;molecular oxygen
- 現地名
- 酸素と混合した二酸化炭素
- 英語名
- CARBOGEN
- 分子式
- CO4
- 分子量
- 76.0083
名称と別名
名称をさらに表示
データベース識別子
- CAS
8063-77-2- PubChem CID
- 62690
物性
構造計算による物性
- 極性表面積
- 68.3 Ų
- 水素結合供与体数
- 0
- 水素結合受容体数
- 4
- 回転可能結合数
- 0
- 重原子数
- 5
- 形式電荷
- 0
- 複雑度
- 18
実験および物理化学的性質
Physical Description
Compressed gas, oxidizing, n.o.s. appears as a gas that liberates oxygen, which intensifies the rate of combustion in a fire. Under prolonged exposure to fire or heat the containers may rupture violently and rocket. Obtain the technical name of the material from the shipping papers and contact CHEMTREC, 800-424-9300 for specific response information.
物理化学的性質
- CAS データベース
- 8063 · 8063-77-2
- EPAの化学物質情報
- Carbon dioxide, mixt. with oxygen (8063-77-2)
安全と法規制
危険有害性情報
Fire Hazards
Excerpt from ERG Guide 122 [Gases - Oxidizing (Including Refrigerated Liquids)]:;Substance does not burn but will support combustion. Some may react explosively with fuels. May ignite combustibles (wood, paper, oil, clothing, etc.). Vapors from liquefied gas are initially heavier than air and spread along ground. Runoff may create fire or explosion hazard. Containers may explode when heated. Ruptured cylinders may rocket. (ERG, 2024)
Health Hazards
Excerpt from ERG Guide 122 [Gases - Oxidizing (Including Refrigerated Liquids)]:;Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas. Contact with gas, liquefied gas or cryogenic liquids may cause burns, severe injury and/or frostbite. Fire may produce irritating and/or toxic gases. (ERG, 2024)
DOT Hazard Classification
Compressed gas, oxidizing, n.o.s.
UN3156
Div 2.2 Non-flammable compressed gas (49 eCFR § 173.115)
Div 2.2 Non-flammable compressed gas (49 eCFR § 173.115);Div 5.1 Oxidizer (49 eCFR § 173.127)
Symbol G: The proper shipping name for which one or more technical names of the hazardous material must be entered in parentheses, in association with the basic description. (49 eCFR §172.203(k))
安全と保護具
Fire Fighting
Excerpt from ERG Guide 122 [Gases - Oxidizing (Including Refrigerated Liquids)]:;Use extinguishing agent suitable for type of surrounding fire.;SMALL FIRE: Dry chemical or CO2.;LARGE FIRE: Water spray, fog or regular foam. If it can be done safely, move undamaged containers away from the area around the fire. Damaged cylinders should be handled only by specialists.;FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)
First Aid
Excerpt from ERG Guide 122 [Gases - Oxidizing (Including Refrigerated Liquids)]:;Refer to the "General First Aid" section. Specific First Aid: Clothing frozen to the skin should be thawed before being removed. In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts. (ERG, 2024)
Nonfire Spill Response
Excerpt from ERG Guide 122 [Gases - Oxidizing (Including Refrigerated Liquids)]:;Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch or walk through spilled material. Stop leak if you can do it without risk. If possible, turn leaking containers so that gas escapes rather than liquid. Do not direct water at spill or source of leak. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Prevent entry into waterways, sewers, basements or confined areas. Allow substance to evaporate. Isolate area until gas has dispersed. CAUTION: When in contact with refrigerated/cryogenic liquids, many materials become brittle and are likely to break without warning. (ERG, 2024)
Isolation and Evacuation
Excerpt from ERG Guide 122 [Gases - Oxidizing (Including Refrigerated Liquids)]:;IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.;LARGE SPILL: Consider initial downwind evacuation for at least 500 meters (1/3 mile).;FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Personal Protective Equipment (PPE)
Excerpt from ERG Guide 122 [Gases - Oxidizing (Including Refrigerated Liquids)]:;Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. Always wear thermal protective clothing when handling refrigerated/cryogenic liquids. (ERG, 2024)
法規制情報
安全データ
- ridadr
- UN 3156
- hazard_class
- 2.2
化学と産業
薬理情報
関連反応
化合物ノート