클로로(2-)프로피온산에틸에스테르

Ethyl 2-chloropropionate

HCID 10807CAS 535-13-7

기본 정보

표준 SMILES
CCOC(=O)C(C)Cl
InChIKey
JEAVBVKAYUCPAQ-UHFFFAOYSA-N
분자식
C5H9ClO2
평균 분자량
136.58 g/mol
단동위원소 질량
136.0291072

이름 및 식별자

우선 이름
Ethyl 2-chloropropionate
IUPAC
ethyl 2-chloropropanoate
현지명
클로로(2-)프로피온산에틸에스테르
영어명
Ethyl 2-chloropropionate
분자식
C5H9ClO2
분자량
136.58

이름 및 동의어

Ethyl 2-chloropropionate535-13-7Ethyl 2-chloropropanoatePropanoic acid, 2-chloro-, ethyl esterETHYL ALPHA-CHLOROPROPIONATELXW30UR82CNSC-522671Propionic acid, 2-chloro-, ethyl esterDTXSID70870595RefChem:138588DTXCID40818303208-610-0
이름 더 보기
클로로(2-)프로피온산에틸에스테르2-클로로프로피온산 에틸oropropionate2-ChloropropioUNII:LXW30UR82CEthyl 2-chloropropio3-Nitrosalicyclic Acidethyl2-chloropropanoateEthyl a-Chloropropionate
2-Chloropropionic Acid Ethyl EsterEthyl-2-chloropropionate2-Chloropropionic acid, ethyl esterEthyl .alpha.-chloropropionate2-Chloropropionic acid-ethyl esterMFCD00000864UNII-LXW30UR82CEINECS 208-610-0

데이터베이스 식별자

CAS
535-13-7
PubChem CID
10807
DTXSID
DTXSID70870595
UNII
LXW30UR82C
EC Number
208-610-0
Nikkaji
J42.281I

물성

구조 계산 물성

XLogP
1.5
극성 표면적
26.3 Ų
수소 결합 공여자 수
0
수소 결합 수용자 수
2
회전 가능 결합 수
3
무거운 원자 수
8

실험 및 물리화학적 성질

Physical DescriptionEthyl 2-chloropropionate appears as a clear colorless liquid with a pungent odor. Denser than water and insoluble in water. Vapors are heavier than air.
Kovats Retention Index · 3건

832;841;851;848;838

857

1229;1232;1250;1254;1288;1290;1226

물리화학적 성질

끓는 점
146 · 146-149 °C (lit.)
밀도
1.072 g/mL · 1.072 g/mL at 25 °C (lit.)
굴절률
20 · n20/D 1.417(lit.)
인화점
101 °F · 101 °F
저장 조건
Flammables area
용해도
알코올: 혼합 가능

화학적 성질

clear colorless liquid

안전 및 규제

GHS 분류

GHS Classification · 5건

Warning

H226 (100%): Flammable liquid and vapor [Warning Flammable liquids];H315 (98.8%): Causes skin irritation [Warning Skin corrosion/irritation];H319 (98.8%): Causes serious eye irritation [Warning Serious eye damage/eye irritation];H335 (96.4%): May cause respiratory irritation [Warning Specific target organ toxicity, single exposure; Respiratory tract irritation]

P210, P233, P240, P241, P242, P243, P261, P264, P264+P265, P271, P280, P302+P352, P303+P361+P353, P304+P340, P305+P351+P338, P319, P321, P332+P317, P337+P317, P362+P364, P370+P378, P403+P233, P403+P235, P405, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 83 reports by companies from 6 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.;Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

유해성 정보

Regulatory Information · 3건

Chemical: Propanoic acid, 2-chloro-, ethyl ester

Status: Active Update: 26-05-2014 https://echa.europa.eu/registration-dossier/-/registered-dossier/10524

The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)

DOT LabelFlammable Liquid
Fire Hazards · 2건

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids will float on water. (ERG, 2024)

· HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.;· Vapors may form explosive mixtures with air.;· Vapors may travel to source of ignition and flash back.;· Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.).;· Vapor explosion hazard indoors, outdoors or in sewers.;· Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.;· Runoff to sewer may create fire or explosion hazard.;· Containers may explode when heated.;· Many liquids will float on water.

Health Hazards · 2건

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;May cause toxic effects if inhaled or absorbed through skin. Inhalation or contact with material may irritate or burn skin and eyes. Fire will produce irritating, corrosive and/or toxic gases. Vapors may cause dizziness or asphyxiation, especially when in closed or confined areas. Runoff from fire control or dilution water may cause environmental contamination. (ERG, 2024)

· May cause toxic effects if inhaled or absorbed through skin.;· Inhalation or contact with material may irritate or burn skin and eyes.;· Fire will produce irritating, corrosive and/or toxic gases.;· Vapors may cause dizziness or asphyxiation, especially when in closed or confined areas.;· Runoff from fire control or dilution water may cause environmental contamination.

DOT ID and Guide2935 129
Reactive GroupEsters, Sulfate Esters, Phosphate Esters, Thiophosphate Esters, and Borate Esters;Halogenated Organic Compounds

안전 및 보호

Fire Fighting · 1건

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient.;SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. Do not use dry chemical extinguishers to control fires involving nitromethane (UN1261) or nitroethane (UN2842).;LARGE FIRE: Water spray, fog or alcohol-resistant foam. Avoid aiming straight or solid streams directly onto the product. If it can be done safely, move undamaged containers away from the area around the fire.;FIRE INVOLVING TANKS, RAIL TANK CARS OR HIGHWAY TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

Accidental Release Measures · 2건

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.;· Keep unauthorized personnel away.;· Stay upwind, uphill and/or upstream.;· Ventilate closed spaces before entering, but only if properly trained and equipped.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.;· All equipment used when handling the product must be grounded.;· Do not touch or walk through spilled material.;· Stop leak if you can do it without risk.;· Prevent entry into waterways, sewers, basements or confined areas.;· A vapor-suppressing foam may be used to reduce vapors.;· Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers.;· Use clean, non-sparking tools to collect absorbed material.;Large Spill;· Dike far ahead of liquid spill for later disposal.;· Water spray may reduce vapor, but may not prevent ignition in closed spaces.

First Aid · 2건

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;Refer to the "General First Aid" section. Specific First Aid: Wash skin with soap and water. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)

General First Aid:;· Call 911 or emergency medical service.;· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.;· Move victim to fresh air if it can be done safely.;· Administer oxygen if breathing is difficult.;· If victim is not breathing:;-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.;-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).;-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.;· Remove and isolate contaminated clothing and shoes.;· For minor skin contact, avoid spreading material on unaffected skin.;· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.;· For severe burns, immediate medical attention is required.;· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.;· Keep victim calm and warm.;· Keep victim under observation.;· For further assistance, contact your local Poison Control Center.;· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.;Specific First Aid:;· Wash skin with soap and water.

Exposure Control and Personal Protection· Wear positive pressure self-contained breathing apparatus (SCBA).;· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.
Nonfire Spill Response · 1건

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material.;LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)

Isolation and Evacuation · 2건

Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]:;IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.;LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).;FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)

Immediate precautionary measure;· Isolate spill or leak area for at least 50 meters (150 feet) in all directions.;Large Spill;· Consider initial downwind evacuation for at least 300 meters (1000 feet).;Fire;· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.

규제 정보

Regulatory Information · 3건

Chemical: Propanoic acid, 2-chloro-, ethyl ester

Status: Active Update: 26-05-2014 https://echa.europa.eu/registration-dossier/-/registered-dossier/10524

The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)

안전 데이터

wgk
3
tsca
TSCA listed
ridadr
UN 2935
HS 번호
29159000
risk_code
10-36/37/38
hazard_code
Xi

화학 및 산업

용도 및 제조

General Manufacturing InformationPropanoic acid, 2-chloro-, ethyl ester: ACTIVE
응용 분야 · 2건

용도Ethyl 2-chloropropionate was used as initiator during the synthesis of poly(2-(diethylamino)ethyl methacrylate) and poly(N-isopropylacrylamide) via atom transfer radical polymerization. It was also used in the synthesis of end-functionalized poly(N-isopropylacrylamide) with pyrenyl group.

일반 설명A clear colorless liquid with a pungent odor. Flash point of 100°F. Denser than water and insoluble in water. Vapors are heavier than air.

공급사50 곳

梯希爱(上海)化成工业发展有限公司021-67121386 · [email protected]
上海阿拉丁生化科技股份有限公司400-6206333 13167063860 · [email protected]
武汉欣扬瑞和化学科技有限公司153-07155313 15307155313 · [email protected]
武汉欣扬瑞和化学科技有限公司18171205315; 18171205315 · [email protected]
淄博创谷化工科技有限公司00-15864498288 15864498288 · [email protected]

관련 반응

53건

연결된 노트

불러오는 중…