홈MCP워크벤치Skills
홈워크벤치알림마이페이지
llms.txt · MCP 가이드개인정보처리방침 · 이용약관 · 지원v1.8.3
  1. 홈
  2. /화합물

중수소

Deuterium

HCID 24523
새 반응
인쇄

데이터를 보충하는 중입니다. 잠시 후 페이지를 새로 고치면 최신 내용을 볼 수 있습니다

기본 정보개요이름 및 식별자물성안전 및 규제화학 및 산업관련 반응화합물 노트
부분 구조 검색유사 구조 찾기

기본 정보

CAS
12184-84-8
표준 SMILES
[2H][2H]
InChIKey
UFHFLCQGNIYNRP-VVKOMZTBSA-N
분자식
H2
평균 분자량
4.0282 g/mol
단동위원소 질량
4.02820356

개요

Deuterium is an isotope of hydrogen but it is chemically identical. It is a colorless, odorless gas. It is easily ignited. Once ignited it burns with a pale blue, almost invisible flame. The vapors are lighter than air. It is flammable over a wide range of vapor/air concentrations. Under prolonged exposure to fire or intense heat the containers may rupture violently and rocket. It is not toxic but is a simple asphyxiate by the displacement of oxygen in the air.

이름 및 식별자

우선 이름
Deuterium
현지명
중수소
영어명
DEUTERIUM
분자식
D2
분자량
4.03

이름 및 동의어

DEUTERIUM7782-39-0DideuteriumHeavy hydrogenHydrogen-2Diplogenhydrogen 2Hydrogen-d2Deuterium moleculeHydrogen, isotope of mass 2AR09D82C7GDTXSID2064810
이름 더 보기
중수소중수소(DEUTERIUM)(2)H2DeuteriuDEUTIRIUMDEUTERRIUM
HYDROGEN H-2CHEBI:29294RefChem:132349DTXCID9048011231-952-7MFCD00064812D2UNII-AR09D82C7G

데이터베이스 식별자

CAS
12184-84-8、7782-39-0
PubChem CID
24523
DTXSID
DTXSID2064810
ChEBI
CHEBI:29294
UNII
AR09D82C7G
EC Number
231-952-7

물성

구조 계산 물성보충 중

XLogP
0
극성 표면적
0 Ų
수소 결합 공여자 수
0
수소 결합 수용자 수
0
회전 가능 결합 수
0
무거운 원자 수
0
형식 전하
0
복잡도
0

실험 및 물리화학적 성질

Chemical Classes · 2건

Other Classes -> Elements, Nonmetallic

Flammable agents - 4th degree

OdorOdorless
Density · 3건

0.169 @ -250.9 °C (LIQUID)

At 20.4 K: density, 169 g/l; viscosity, 4.0X10-2 cP; surface tension, 3.7 mN/m; thermal conductivity, 12.6 W/cm.K; dielectric constant, 1.27 /Liquid equilibrium D2 (97.8% ortho-D2)/

0.169 @ -250.9°C

Color/FormCOLORLESS GAS
SolubilitySLIGHTLY SOL IN COLD WATER
CorrosivityNoncorrosive
Boiling Point · 2건

-249.49 °C

-249.49 °C @760 [mm Hg]

Melting Point · 3건

-254.43 °C @ 128.5 mm Hg

Critical temp: 38.3 K; critical pressure: 16.28 atm; critical volume: 60.4 cu cm/mol /Equilibrium deuterium/

-254.43 °C

Vapor Pressure17.14 kPa

안전 및 규제

안전 정보는 참고용이며, 공급업체의 물질안전보건자료(SDS), 관련 법규 및 전문가 평가를 대체하지 않습니다.

GHS 분류

GHS Classification · 6건

Danger

H220 (97.6%): Extremely flammable gas [Danger Flammable gases]

P203, P210, P222, P280, P377, P381, P403, and P410+P403 (click each P-code to see the statement)

Aggregated GHS information provided per 123 reports by companies from 6 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Danger

H220: Extremely flammable gas [Danger Flammable gases]

유해성 정보

Regulatory Information · 3건

Status: Active Update: 22-06-2020 https://echa.europa.eu/registration-dossier/-/registered-dossier/20919

Deuterium: HSNO Approval: HSR000993 Approved with controls

The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)

DOT LabelFlammable Gas
Fire Hazards · 2건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:

· EXTREMELY FLAMMABLE.

Fire PotentialVery dangerous fire and explosion hazard when exposed to heat, flame, sparks and oxidizers.
Health Hazards · 2건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:

· Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas.

Hazards SummaryThe stable isotope of hydrogen. It has one neutron and one proton in the nucleus. [ChemIDplus] Chemically identical to hydrogen; May act as a simple asphyxiant; [CAMEO]

화학 및 산업

용도 및 제조

Uses · 5건

Used as a tracer in chemical reactions; [Merck Index] Used to produce heavy water (D2O2), a moderator of neutrons in nuclear reactors; [Ullmann]

Extensively in small amt as tracer in establishment of rates and kinetics of chemical reactions.

Explosive in hydrogen bomb as lithium deuteride

Bombardment of atomic nuclei, tracer element, thermonuclear reactions.

Deuterium has very desirable properties as a moderator for neutrons.

Methods of Manufacturing · 3건

May be obtained by electrolysis of heavy water (obtained by hydrogen sulfide/water exchange process) or by fractional distillation of liq hydrogen: Urey et al, Phys Rev, 39, 164 (1932); Spevack, US patent 2,787,526 (1957 to USAEC).

Chemical exchange between hydrogen and water or hydrogen and ammonia; distillation of water ... and electrolysis of water in combination with other procedures. /Production of heavy water/

Electrolysis of high-purity heavy water, fractional distillation of liquid hydrogen.

Formulations/PreparationsGrades: 98, 99.5 atom %.
General Manufacturing Information · 6건

Deuterium: ACTIVE

An isotope of hydrogen whose nucleus contains one neutron and one proton, and is therefore twice as heavy (atomic weight 2.014) as the nucleus of normal hydrogen.

If controlled thermonuclear fusions can be achieved, deuterium gas will become increasingly important.

Heavy water, D2O, is the most important cmpd of deuterium and the only form of deuterium produced ... on a large scale.

... The ortho form of deuterium is more stable than the para form at low temp, and at normal temp the ratio of ortho to para deuterium is 2:1 in contrast to the 3:1 ratio for hydrogen.

For more General Manufacturing Information (Complete) data for DEUTERIUM (6 total), please visit the HSDB record page.

응용 분야 · 2건

용도Used extensively in small amounts as tracer in the establishment of rates and kinetics of chemical reactions.

관련 반응

3건
반응 기록 만들기
HRID 322591 반응식
HRID 322591반응물로
HRID 322592 반응식
HRID 322592반응물로
HRID 322593 반응식
HRID 322593반응물로

화합물 노트

이 페이지에서기본 정보개요이름 및 식별자물성안전 및 규제화학 및 산업관련 반응화합물 노트
Heat of Vaporization
1225 J/mol
Physical Description · 2건

Deuterium is an isotope of hydrogen but it is chemically identical. It is a colorless, odorless gas. It is easily ignited. Once ignited it burns with a pale blue, almost invisible flame. The vapors are lighter than air. It is flammable over a wide range of vapor/air concentrations. Under prolonged exposure to fire or intense heat the containers may rupture violently and rocket. It is not toxic but is a simple asphyxiate by the displacement of oxygen in the air.

Odorless, flammable gas; [CAMEO]

Autoignition Temperature1085 °F

물리화학적 성질

녹는점
-254.43 ° · -254.43° (18.73 K) at 128.5 mm (triple point)
끓는 점
-249.5 °C · -249.5 °C(lit.)
밀도
0.169 g/mL · 0.169 g/mL at 25 °C(lit.)
증기 밀도
0.07 · 0.07 (vs air)
증기압
17.1 · 17.1-1665kPa at -254.43--234.8℃
물리적 상태
가스
색상
무색의
Merck
13 · 13,2956
Henry's Law Constant
7.9 · 7.9×10-6 mol/(m3Pa) at 25℃, Muccitelli and Wen (1978)
Dielectric constant
1.3 · 1.3(20℃)
안정성
안정적인. 가연성이 매우 높습니다. 공기와 쉽게 폭발성 혼합물을 형성합니다.
InChI
InChI=1S/H2/h1H/i1+1D
InChIKey
UFHFLCQGNIYNRP-VVKOMZTBSA-N
SMILES
[2H][2H]
EPA
Deuterium (7782-39-0)
CAS Number Unlabeled
1333 · 1333-74-0

화학적 성질

colourless gas

DOT ID and Guide
1957 115
Reactive GroupReducing Agents, Weak
Reactivity AlertsHighly Flammable
Reactivity ProfileDeuterium, like hydrogen, is a reducing agent; reacts readily with oxidizing agents.
Flammable LimitsLOWER: 5%; UPPER: 75% (% BY VOLUME)
DOT Emergency Guidelines · 5건

/GUIDE 115: GASES - FLAMMABLE (INCLUDING REFRIGERATED LIQUIDS)/ Fire or Explosion: EXTREMELY FLAMMABLE. Will be easily ignited by heat, sparks or flames. Will form explosive mixtures with air. Vapors from liquefied gas are initially heavier than air and spread along ground. ... Vapors may travel to source of ignition and flash back. Cylinders exposed to fire may vent and release flammable gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket. /Deuterium; Deuterium, compressed/

/GUIDE 115: GASES - FLAMMABLE (INCLUDING REFRIGERATED LIQUIDS)/ Health: Vapors may cause dizziness or asphyxiation without warning. Some may be irritating if inhaled at high concentrations. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. Fire may produce irritating and/or toxic gases. /Deuterium; Deuterium, compressed/

/GUIDE 115: GASES - FLAMMABLE (INCLUDING REFRIGERATED LIQUIDS)/ Public Safety: CALL Emergency Response Telephone Number. ... As an immediate precautionary measure, isolate spill or leak area for at least 100 meters (330 feet ) in all directions. Keep unauthorized personnel away. Stay upwind. Many gases are heavier than air and will spread along ground and collect in low or confined areas (sewers, basements, tanks). Keep out of low areas. /Deuterium; Deuterium, compressed/

/GUIDE 115: GASES - FLAMMABLE (INCLUDING REFRIGERATED LIQUIDS)/ Protective Clothing: Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing will only provide limited protection. Always wear thermal protective clothing when handling refrigerated/cryogenic liquids. /Deuterium; Deuterium, compressed/

For more DOT Emergency Guidelines (Complete) data for DEUTERIUM (8 total), please visit the HSDB record page.

안전 및 보호

Fire FightingExcerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:
Accidental Release Measures · 2건

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

First Aid · 2건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:

General First Aid:

Exposure Control and Personal Protection· Wear positive pressure self-contained breathing apparatus (SCBA).
Fire Fighting Procedures · 1건

If material on fire or involved in fire: Do not extinguish fire unless flow can be stopped. Use water in flooding quantities as fog. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible.

Storage Conditions · 4건

Never use cylinders of deuterium in areas where flames, excessive heat or sparks may occur. Utilize only explosion proof equipment and spark proof tools in areas where deuterium is handled.

Ground all equipment and lines used with deuterium. Never use a flame to detect gas leaks, use soapy water.

Do not store reserve stocks of deuterium with cylinders containing oxygen, or with other highly oxidizing or combustible materials.

Do not place cylinders where they may become part of an electric circuit.

Nonfire Spill ResponseExcerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:
Disposal Methods · 1건

SRP: At the time of review, criteria for land treatment or burial (sanitary landfill) disposal practices are subject to significant revision. Prior to implementing land disposal of waste residue (including waste sludge), consult with environmental regulatory agencies for guidance on acceptable disposal practices.

Preventive Measures · 2건

If material not on fire and not involved in fire: Keep sparks, flames, and other sources of ignition away. Attempt to stop leak if without undue personnel hazard. Use water spray to knock-down vapors.

Personnel protection: Avoid breathing vapors. Keep upwind. ... Do not handle broken packages unless wearing appropriate personal protective equipment. Approach fire with caution.

Isolation and Evacuation · 2건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:

Immediate precautionary measure

Protective Action Criteria (PAC) · 3건

65000 [ppm]

230000 [ppm]

400000 [ppm]

Personal Protective Equipment (PPE) · 2건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:

Personnel protection: ... Wear appropriate chemical protective gloves and goggles.

독성 정보

Adverse EffectsOther Poison - Simple Asphyxiant
Natural Pollution SourcesOccurs in nature in all hydrogen-containing cmpd to the extent of about 0.0145 atom %.
Human Toxicity ExcerptsCONSIDERED NONTOXIC (EXCEPT FOR ITS ASPHYXIATING & FLAMMABLE PROPERTIES) AS USED IN LABORATORIES & NUCLEAR POWER PLANTS.
Non-Human Toxicity Excerpts · 1건

Replacement of more than one-third of the hydrogen by deuterium in body fluids of mammals or two-thirds of the hydrogen in higher green plants has catastrophic consequences for the organisms. At lower levels of deuterium in higher plants, growth is markedly slowed. In mice and rats low levels of deuterium result in sterility, and at higher concn neuromuscular disturbances, fine muscle tremors, and a tendency to convulsions can be noted. ... Impairment of kidney function, anemia, disturbed carbohydrate metabolism, central nervous system disturbances, and altered adrenal function /were found/ in deuterated mice. Hemoglobin and RBC count, serum glucose, and cholesterol all decrease in deuterated dogs. ... /However/ numerous green and blue-green algae have been grown in which > 99.5% of the hydrogen has been replaced by D. ... Numerous varieties of bacteria, molds, fungi, and even a protozoan have been successfully grown in fully deuterated form.

안전 데이터

wgk
1
tsca
TSCA listed
ridadr
UN 1957 (DEUTERIUM, COMPRESSED)
risk_code
12
hazard_code
F+
safety_code
9-16-33
위험 등급
2.1
기존화학 물질
KE-09620
유해 물질 데이터
7782-39-0(Hazardous Substances Data)

일반 설명DEUTERIUM is an isotope of hydrogen but DEUTERIUM is chemically identical. DEUTERIUM is a colorless, odorless gas. DEUTERIUM is easily ignited. Once ignited DEUTERIUM burns with a pale blue, almost invisible flame. The vapors are lighter than air. DEUTERIUM is flammable over a wide range of vapor/air concentrations. Under prolonged exposure to fire or intense heat the containers may rupture violently and rocket. DEUTERIUM is not toxic but is a simple asphyxiate by the displacement of oxygen in the air.

상·하류 제품 정보

하류 제품

fluoro surfactant FC-154fluorocarbon sulfactant 6201
추가 설명 · 1건

정의A naturally occurring stable isotope of hydrogen in which the nucleus contains one proton and one neutron. The atomic mass is thus approximately twice that of 1H; deuterium is known as ‘heavy hydrogen’. Chemically it behaves almost identically to hydrogen, forming analogous compounds, although reactions of deuterium compounds are often slower than those of the corresponding 1H compounds. This is made use of in kinetic studies where the rate of a reaction may depend on transfer of a hydrogen atom (i.e. a kinetic isotope effect).