포스포러스옥시클로라이드

Phosphorus oxychloride

HCID 24813
새 노트새 반응견적 요청하기
인쇄 미리보기
기본 정보개요이름 및 식별자물성안전 및 규제화학 및 산업관련 반응화합물 노트
부분 구조 검색유사 구조 찾기

기본 정보

CAS
10025-87-3
표준 SMILES
O=P(Cl)(Cl)Cl
InChIKey
XHXFXVLFKHQFAL-UHFFFAOYSA-N
분자식
Cl3OP
평균 분자량
153.33 g/mol
단동위원소 질량
151.875235

개요

Phosphorus oxychloride appears as a colorless fuming liquid with a pungent odor. Density 14.0 lb / gal. Very toxic by inhalation and corrosive to metals and tissue. Used in gasoline additives and hydraulic fluids.

이름 및 식별자

우선 이름
Phosphorus oxychloride
IUPAC
phosphoryl trichloride
현지명
포스포러스옥시클로라이드
영어명
Phosphorus oxitrichloride
분자식
Cl3OP
분자량
153.33

이름 및 동의어

PHOSPHORUS OXYCHLORIDEPhosphoryl chloride10025-87-3Phosphoryl trichloridePhosphoric trichloridePhosphorous oxychlorideTrichlorophosphine oxidePhosphorus oxytrichloridePhosphoroxychlorideFosforoxychloridTrichlorophosphorus oxideOxychlorid fosforecny
이름 더 보기
염화포스포릴인모노산화물트리염화물인염화물산화물인염화물산화물(POCL3)인트리염화물산화물트리클로로인산화물트리클로로포스핀산화물포스포러스옥시클로라이드포스포르염화물포스포르트리염화물포스포르옥시트리염화물포스포릴염화물포스포릴트리염화물옥시염화인포스포러스옥시클로라이드산화염화 인옥시염화 인인 모노산화물 삼염화물인 산화물 삼염화물인 삼염화물 산화물POCl3oxychloridePHOSPHORUS(V) OXYCHLORIDEPhosphoryl oxychlorideOPCl3
Phosphorus oxide trichlorideDTXSID5029710Phosphorus chloride oxide (POCl3)9XM78OL22KDTXCID609710CHEBI:30336RefChem:862976233-046-7

데이터베이스 식별자

CAS
10025-87-3
PubChem CID
24813
DTXSID
DTXSID5029710
ChEMBL
CHEMBL3183103
ChEBI
CHEBI:30336
UNII
9XM78OL22K
EC Number
233-046-7
Nikkaji
J95.147A

물성

구조 계산 물성

XLogP
1.7
극성 표면적
17.1 Ų
수소 결합 공여자 수
0
수소 결합 수용자 수
1
회전 가능 결합 수
0
무거운 원자 수
5
형식 전하
0
복잡도
53

실험 및 물리화학적 성질

Chemical Classes · 2건

Toxic Gases & Vapors -> Acid Halides

Corrosives

SpringerMaterials PropertiesGibbs energy
OdorPungent & musty odor
Food AdditivesPH CONTROL AGENT -> FDA Substance added to food
Density · 6건

1.645 at 77 °F (EPA, 1998) - Denser than water; will sink

Specific gravity: 1.645 at 25 °C/4 °C

Relative density (water = 1): 1.645

1.645 at 77 °F

1.685 @ 15.5°C

(77 °F): 1.65

Color/Form · 2건

Clear, colorless to yellow, oily liquid [Note: A solid below 34 degrees F].

Mobile, fuming liquid

Solubility · 4건

Decomposes (NIOSH, 2024)

Reacts with water

Solubility in water: reaction

Decomposes

CorrosivityPRODUCTS OF ITS REACTION WITH WATER RAPIDLY CORRODE STEEL & MOST METALS
Flash PointNot Flammable (EPA, 1998)

안전 및 규제

안전 정보는 참고용이며, 공급업체의 물질안전보건자료(SDS), 관련 법규 및 전문가 평가를 대체하지 않습니다.

GHS 분류

GHS Classification · 6건

Danger

H302: Harmful if swallowed [Warning Acute toxicity, oral]

P260, P264, P270, P271, P280, P284, P301+P317, P301+P330+P331, P302+P361+P354, P304+P340, P305+P354+P338, P316, P319, P320, P321, P330, P363, P403+P233, P405, and P501 (click each P-code to see the statement)

This chemical does not meet GHS hazard criteria for 3.3% (12 of 359) of reports.

Danger

H290 (37.3%): May be corrosive to metals [Warning Corrosive to Metals]

유해성 정보

Hazards IdentificationToxic/poison by inhalation (TIH/PIH)
Regulatory Information · 5건

Chemical: Phosphoryl chloride

Phosphoric trichloride is listed on the EPA's Chemical Data Reporting (CDR) system. Manufacturers and importers of Phosphoric trichloride are required to report information about their production and use of this chemical to the EPA under the Toxic Substances Control Act (TSCA). (40 eCFR Part 711)

REACH registered substance: Phosphoryl trichloride (EC: 233-046-7)

Phosphoryl chloride: Does not have an individual approval but may be used under an appropriate group standard

The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)

Other Safety InformationIMAP assessments - Phosphoryl chloride: Human health tier I assessment
DOT LabelPoison Inhalation Hazard Corrosive
Fire Hazards · 3건

Poisonous, corrosive, and irritating gases are generated when this material is heated or is in contact with water. It may ignite other combustible materials (wood, paper, oil, etc.). It reacts violently with water. When heated to decomposition, it emits toxic fumes of chlorides and oxides of phosphorus; it will react with water or steam to produce heat and toxic and corrosive fumes. Incompatible with carbon disulfide; N,N-dimethylformamide; 2,5-dimethylpyrrole; 2,6-dimethyl- pyridine N-oxide; dimethylsulfoxide; Ferrocene-1,1-dicarboxylic acid; water; and zinc. Do not store with combustible materials, particularly fibrous organic materials, or with electrical or other equipment that can be corroded. Reacts violently with moisture. (EPA, 1998)

화학 및 산업

약리 정보

Absorption, Distribution and Excretion · 1건

At low concentrations the free acids resulting from the hydrolysis of phosphoryl trichloride will be neutralised quickly by body fluids. The resulting phosphate and chloride ions are natural components of food and ubiquitously found in living tissues and are not expected to pose a hazard. At high concentrations, which exceed the buffer capacity of body fluids the acids will damage the tissue at the portal of entry dependent upon concentration and duration of exposure. A systemic availability of phosphoryl trichloride or the free acids is hence not expected.

용도 및 제조

Uses · 6건

Used in chemical synthesis as a chlorinating agent and catalyst and to produce plasticizers, hydraulic fluids, gasoline additives, and fire retardants; [ACGIH]

Semiconductor Manufacturing [Category: Industry]

Precursor to N,N-dimethylphosphoramidic dichloride

Phosphoryl trichloride can be converted by multistage chemical synthesis to nerve gases. Therefore the production and export of phosphoryl trichloride is stringently controlled under the International Chemical Weapons Convention (1993). The Chemical Weapons Convention lists phosphoryl trichloride as /a/ precursor to chemical weapons.

Phosphorus oxychloride is used extensively to manufacture alkyl and aryl orthophosphate triesters.

Solvent in cryoscopy

U.S. Exports · 1건

CHEMICAL PROFILE: Phosphorus oxychloride: Combined exports of phosphorus trichloride and oxychloride averaged 1,600 tons per year in the 1992-1995 period. ... Exports of oxychloride are estimated to have made up only 30 to 40 percent of the combined volume.

U.S. Imports · 3건

(1972) NEGLIGIBLE

(1975) 8.67X10+8 GRAMS

(1984) 1.62X10+8 G

U.S. Production · 6건

2023: 10,000,000 - <25,000,000 lb

(1972) 3.14X10+10 GRAMS

(1975) 3.13X10+10 GRAMS

(1984) 2.67X10+10 G

관련 반응

17,281건
반응 기록 만들기
HRID 996 반응식
HRID 996반응물로uspto-grants-1998_03
HRID 1504 반응식
HRID 1504반응물로uspto-grants-1998_03
HRID 1571 반응식
HRID 1571반응물로uspto-grants-1998_03
HRID 1709 반응식
HRID 1709반응물로uspto-grants-1998_03
HRID 1844 반응식
HRID 1844반응물로uspto-grants-1998_03
HRID 1949 반응식
HRID 1949반응물로uspto-grants-1998_03
HRID 1954 반응식
HRID 1954반응물로uspto-grants-1998_03
HRID 2076 반응식
HRID 2076반응물로uspto-grants-1998_03
1 / 500 페이지

화합물 노트

불러오는 중…

이 페이지에서기본 정보개요이름 및 식별자물성안전 및 규제화학 및 산업관련 반응화합물 노트
더보기
새 노트새 반응견적 요청하기
Boiling Point · 6건

223 °F at 760 mmHg (EPA, 1998)

105.8 °C

105.8 °C

223 °F

105.1 °C @760 [mm Hg]

222 °F

Decomposition · 2건

WHEN HEATED TO DECOMPOSITION, IT EMITS HIGHLY TOXIC FUMES OF CHLORIDES AND PO(X).

PRODUCES PHOSPHORUS TRICHLORIDE & CHLORINE WHEN HEATED; PRODUCES PHOSPHORUS OXYCHLORIDE, PHOSPHORIC ACID, & HYDROCHLORIC ACID WHEN DECOMPOSED IN WATER

Melting Point · 6건

34.2 °F (EPA, 1998)

1.25 °C

1 - 1.5 °C

1.25 °C

34.2 °F

1.2 °C

물리화학적 성질

녹는점
1.25 °C · 1.25 °C(lit.)
끓는 점
107 °C · 107 °C
밀도
1.645 g/mL · 1.645 g/mL at 25 °C(lit.)
증기 밀도
5.3 · 5.3 (vs air)
증기압
104 mm · 104 mm Hg ( 50 °C)
굴절률
20 · n20/D 1.461
인화점
105.8 °C · 105.8°C
저장 조건
30 °C · Store below +30°C.
용해도
인(V) 옥시염화물은 많은 유기 용매에 용해됩니다.
물리적 상태
액체
Specific Gravity
1.692 · 1.692 (15/15℃)
색상
무색의
수소이온지수(pH)
1 · 1.0 (5g/l, H2O, 25℃)
냄새
매운 냄새
수용성
발열 반응
비열
0.91 J/ · Cp(liquid): 0.91 J/(g·K); Cp(gas): 0.55 J/(g·K), at 25℃
Merck
14 · 14,7349
Dielectric constant
14 · 14.0(22℃)
안정성
안정적인. 물과 격렬하게 반응함. 많은 금속, 알코올, 아민, 페놀, DMSO, 강염기와 호환되지 않습니다.
InChI
1S/Cl3OP/c1-5(2,3)4
InChIKey
XHXFXVLFKHQFAL-UHFFFAOYSA-N
LogP
0.357 · 0.357 (est)
NIST
Phosphoryl chloride(10025-87-3)
EPA
Phosphorus oxychloride (10025-87-3)

화학적 성질

Phosphorus oxychloride is a clear, colorless to yellow, fuming, oily liquid with a pungent and musty odor.

· EXCEPT FOR ACETIC ANHYDRIDE (UN1715), THAT IS FLAMMABLE, some of these materials may burn, but none ignite readily.

Not combustible. Gives off irritating or toxic fumes (or gases) in a fire.

Fire PotentialPRODUCTS OF ITS REACTION WITH WATER RAPIDLY CORRODE STEEL & MOST METALS WITH FORMATION OF FLAMMABLE HYDROGEN GAS.
Health Hazards · 2건

Health Hazards : This poison is toxic by inhalation and ingestion and is strongly irritating to skin and tissues. It causes burns of the mucous membranes of the mouth and digestive tractand may be fatal. (EPA, 1998)

· CORROSIVE and/or TOXIC; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death.

Hazards Summary · 1건

Liquid causes second or third degree burns after short contact; [CHRIS] Highly corrosive to skin; [Quick CPC] Mucous membrane irritation, bronchitis, pulmonary edema, and nephritis have been reported after occupational exposure. [ACGIH] Liver injury in animals in a chronic study; [Desai, H. Phosphorus and Phosphorus Compounds. In: Sullivan J, Krieger G (eds). Hazardous Materials Toxicology. Baltimore:Williams & Wilkins,1992;939] A corrosive substance that can cause pulmonary edema; [ICSC] A lachrymator; [CHEMINFO]

DOT ID and Guide · 2건

1810 137

1810 137

Reactive GroupAcyl Halides, Sulfonyl Halides, and Chloroformates
EC ClassificationSymbol: T+, C; R: 14-22-26-29-35-48/23; S: (1/2)-7/8-26-36/37/39-45
UN ClassificationUN Hazard Class: 8; UN Pack Group: II

안전 및 보호

Fire Fighting · 2건

Avoid breathing vapors; keep upwind. Wear self-contained breathing apparatus. Avoid bodily contact with the material. Wear boots, protective gloves, and goggles. Do not handle broken packages without protective equipment. Wash away any material which may have contacted the body with copious amounts of water or soap and water. If contact with the material is anticipated, wear full protective clothing. Keep unnecessary people away; isolate hazard area and deny entry.

In case of fire in the surroundings, use appropriate extinguishing media. NO hydrous agents. NO water. In case of fire: keep drums, etc., cool by spraying with water. NO direct contact with water.

First Aid Measures · 4건

Fresh air, rest. Half-upright position. Artificial respiration may be needed. Refer for medical attention.

Remove contaminated clothes. Rinse skin with plenty of water or shower. Refer for medical attention .

First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.

Rinse mouth. Do NOT induce vomiting. Refer for medical attention .

Accidental Release Measures · 2건

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Do not touch damaged containers or spilled material unless wearing appropriate protective clothing.

First Aid · 3건

Warning: Phosphorus oxychloride is a corrosive agent. Contact with eyes may result in severe damage to the cornea, conjunctiva, and blood vessels. Caution is advised.

General First Aid:

(General first aid procedures)

Safe StorageSee Chemical Dangers. Cool. Dry. Well closed. Keep in a well-ventilated room.
Firefighting Hazards · 2건

Not combustible, but if involved in a fire may react to produce hydrogen chloride & phosphoric acid.

Fumes from fires are irritating to respiratory passages, eyes, skin, & may contain phosphine, phosphoric acid, hydrogen chloride.

Exposure Control and Personal Protection · 3건

· Wear positive pressure self-contained breathing apparatus (SCBA).

TIH (Toxic Inhalation Hazard) - Term used to describe gases and volatile liquids that are toxic when inhaled. Some are TIH materials themselves, e.g., chlorine, and some release TIH gases when spilled in water, e.g., chlorosilanes. [ERG 2016].

0.02 [ppm]

Fire Fighting Procedures · 2건

Use appropriate extinguishing agents on nearby combustible fires. Use water spray to knock down acid vapors.

This chemical reacts violently with moisture producing hydrochloric and phosphoric acids. Poisonous gases including chlorides and phosphorus oxides are produced in fire. Do not use water unless used in flooding quantities to control a large fire by wetting down combustibles burning in vicinity of this material. Use dry chemical, carbon dioxide, or dry sand; do not use water on material itself. Use water spray to absorb vapors and cool all affected containers with flooding quantities of water. Apply water from a s far a distance as possible. Avoid breathing vapors; keep upwind. Wear self-contained breathing apparatus. Avoid bodily contact wit the material. Wear boots, protective gloves, and goggles. Do not handle broken packages without protective equipment. Wash away any material which may have contacted the body with copious amounts of water or soap and water. If contact with the material is anticipated, wear full protective clothing. Keep unnecessary people away; isolate hazard area and deny entry. Vapors are heavier than air and will collect in low areas. Containers may explode in fire. Storage containers and parts of containers may rocket great distances, in many directions. ...From a secure, explosion-proof location, use water spray to cool exposed containers. If cooling streams are ineffective (venting sound increases in volume and pitch, tank discolors, or shows any signs of deforming), withdraw immediately to a secure position.

Storage Conditions · 4건

Keep in tightly closed containers.

Store in a cool, dry, well-ventilated location. Separate from acids, alkalies, alkali metals, alcohols.

Phosphorus oxychloride is stored and shipped in 3.8-L (1-gal) or smaller glass containers and DOT-specification wooden overpacking. Bulk POCl3 shipments are in nickel-clad tank cars of 15,000-30,000 L (4000-8000 gal) each. Glass and glass-lined steel equipment frequently is used for storage, as well as for reaction vessels.

Where possible, automatically pump liquid from drums or other storage containers to process containers. Sources of ignition such as smoking and open flames are prohibited where this chemical is handled, used, or stored. Metal containers involving the transfer of 5 gallons or more of this chemical should be grounded and bonded. Drums must be equipped with self-closing valves, pressure vacuum bungs, and flame arresters. Use only non-sparking tools and equipment, especially when opening and closing containers of this chemical. Wherever this chemical is used, handled , manufactured, or stored, use explosion-proof electrical equipment and fittings.

Cleanup Methods · 2건

Releases may require isolation or evacuation. Use water spray to cool & disperse vapors & protect personnel.

Keep material out of water sources and sewers; build dikes to contain flow as necessary; use water spray to knock down vapors; do not use water on material itself; and neutralize spilled material with crushed limestone, soda ash, or lime. For a land spell, dig a pit, pond, lagoon, or holding area to contain liquid or solid material; dike surface flow using soil. sand bags, foamed polyurethane, or foamed concrete; absorb bulk liquid with fly ash or cement powder; neutralize with agricultural lime (slaked lime), crushed limestone, or sodium bicarbonate. For a water spill, neutralize with agricultural lime (slaked lime), crushed limestone, or sodium bicarbonate; use mechanical dredges or lifts to remove immobilized masses of pollutants and precipitates; adjust pH to neutral (pH 7). For air spills apply water spray or mist to knock down vapors; vapor knock down water is corrosive or toxic and should be diked for containment. Stop leak if you can do so without risk. Do not touch spilled material. Keep combustibles (wood, paper, oil, etc.) away from spilled material. Clean up only under supervision of an expert. Keep this chemical out of a confined space, such as a sewer, because of the possibility of an explosion, unless the sewer is designed to prevent the build-up of explosive concentrations. It may be necessary to contain and dispose of this chemical as a hazardous waste. If material or contaminated runoff enters water ways, notify downstream users of potentially contaminated waters.

Nonfire Spill ResponseExcerpt from ERG Guide 137 [Substances - Water-Reactive - Corrosive]:
Disposal Methods · 1건

Principles and methods for destruction of chemical weapons: ... "Destruction of chemical weapons" means a process by which chemicals are converted in an essentially irreversible way to a form unsuitable for production of chemical weapons, and which in an irreversible manner renders munitions and other devices unusable as such. ... Each ... /nation/ shall determine how it shall destroy chemical weapons, except that the following processes may not be used: dumping in any body of water, land burial or open-pit burning. It shall destroy chemical weapons only at specifically designated and appropriately designed and equipped facilities. ... Each ... /nation/ shall ensure that its chemical weapons destruction facilities are constructed and operated in a manner to ensure the destruction of the chemical weapons; and that the destruction process can be verified under the provisions of this Convention.

독성 정보

Target OrgansEyes, skin, respiratory system, central nervous system, kidneys
Environmental Fate · 3건

TERRESTRIAL FATE: Hydrolysis is expected to be the most important fate process for phosphorus oxychloride in the environment(1). Phosphorus oxychloride is expected to volatilize from dry soil surfaces(SRC) based upon a vapor pressure of 40 mm Hg(1).

AQUATIC FATE: Phosphorus oxychloride hydrolyzes rapidly in water at room temperature(1).

ATMOSPHERIC FATE: According to a model of gas/particle partitioning of semivolatile organic compounds in the atmosphere(1), phosphorus oxychloride, which has a vapor pressure of 40 mm Hg at 27.3 °C(2), is expected to exist solely as a vapor in the ambient atmosphere. Vapor-phase phosphorus oxychloride is degraded in the atmosphere by reaction with photochemically-produced hydroxyl radicals(SRC); the half-life for this reaction in air is reported to be >290 days, calculated from its rate constant of <4X10-14 cu cm/molecule-sec at 25 deg(3). Phosphorus oxychloride does not contain chromophores that absorb at wavelengths >290 nm(4) and therefore is not expected to be susceptible to direct photolysis by sunlight(SRC).

Adverse EffectsOccupational hepatotoxin - Secondary hepatotoxins: the potential for toxic effect in the occupational setting is based on cases of poisoning by human ingestion or animal experimentation.
Exposure Routes · 2건

The substance can be absorbed into the body by inhalation of its vapour and by ingestion.

inhalation, ingestion, skin and/or eye contact

Toxicity Summary · 1건

Phosphorus oxychloride. No toxicokinetic studies were located. Phosphorus oxychloride is acutely very toxic when inhaled by rats and guinea pigs, causing extensive irritation of the respiratory tract. It is also acutely toxic to rats via the oral route. The substance is corrosive to rabbit skin and causes severe eye damage. Little reliable information is available on the effects of repeated inhalation in animals. Irritation of the respiratory tract would be expected and has been claimed in one poorly reported rat study, although no reliance can be placed on these data, particularly as it is not clear if continuous or repeated exposure was used. No reliable genotoxicity or animal reproductive toxicity data are available. No animal carcinogenicity study was located. Single exposure of humans to airborne material has been reported to cause conjunctivitis, pharyngitis and respiratory tract irritation, including pulmonary edema. No reliable threshold concentration for these effects is available. Similar effects were seen following repeated exposure including asthmatic bronchitis and, in severe cases, emphysema. Exposure levels were 10-20 mg/cu m, rising to 70 mg/cu m, and sometimes to higher levels. Workers who suffered respiratory effects were reported to show increased respiratory tract sensitivity to phosphorus oxychloride and to other irritant substances, particularly phosphorus bichloride and pentachloride. No human data are available on the genotoxic or carcinogenic potential of phosphorus oxychloride or on its potential to cause reproductive toxicity.

Signs and Symptoms · 5건

Sore throat. Cough. Burning sensation. Dizziness. Laboured breathing. Nausea. Headache. Unconsciousness. Vomiting. Weakness. Shortness of breath. Symptoms may be delayed.

Pain. Redness. Blisters. Skin burns.

Pain. Redness. Severe deep burns. Loss of vision.

Burning sensation. Abdominal pain. Shock or collapse. Further see Inhalation.

irritation eyes, skin, respiratory system; eye, skin burns; dyspnea (breathing difficulty), cough, pulmonary edema; dizziness, headache, lassitude (weakness, exhaustion); abdominal pain, nausea, vomiting; nephritis

Soil Adsorption/MobilityPhosphorus oxychloride hydrolyzes rapidly in water at room temperature(1), and therefore will not adsorb to soils and sediments(SRC).
Human Toxicity Excerpts · 5건

/SIGNS AND SYMPTOMS/ Potential symptoms of overexposure are irritation of eyes, skin, respiratory system; eye, skin burns; dyspnea, cough, lung edema; dizziness, headache, weakness; abdominal pain, nausea, vomiting; nephritis.

/SIGNS AND SYMPTOMS/ Acute poisoning is characterized by burns and extensive reddening of eyes, pains in throat and bronchi, and cough. Those constantly or frequently exposed to very small doses ... suffer from chronic poisoning which manifests itself in form of pulmonary irritation, cough, and when ingested, asthmatical respiration. /it/ ... causes actual burns of mucous membranes of mouth and the digestive tract.

/SIGNS AND SYMPTOMS/ Burns of ... cornea ... have been noted in 2 cases to be slow in healing ... .

/SIGNS AND SYMPTOMS/ Exposure to the vapor of phosphorus oxychloride may cause irritation of the eyes, dizziness, headache, weakness, anorexia, nausea, vomiting, chest pain, cough, dyspnea, bronchitis, bronchopneumonia, pulmonary edema and nephritis. Both chronic and acute cases of occupational intoxication have been recorded.

For more Human Toxicity Excerpts (Complete) data for PHOSPHORUS OXYCHLORIDE (14 total), please visit the HSDB record page.

Artificial Pollution Sources · 1건

Phosphorus oxychloride's production and use to manufacture alkyl and aryl orthophosphate triesters(1), manufacture of insecticides, dye intermediates, pharmaceuticals, synthesis of various nerve agents(2), solvent in cryoscopy(3), manufacture of gasoline additives and hydraulic fluid, chlorinating agent and catalyst, dopant for semiconductor grade silicon, tricresyl phosphate, and fire retarding agent(4) may result in its release to the environment through various waste streams(SRC).

Environmental BioconcentrationPhosphorus oxychloride hydrolyzes rapidly in water at room temperature(1), and therefore is not expected to bioconcentrate in organisms(SRC).
Volatilization from Water/Soil · 1건

Phosphorus oxychloride hydrolyzes rapidly in water at room temperature(1), and therefore will not volatilize from water or moist soil surfaces(SRC). Phosphorus oxychloride is expected to volatilize from dry soil surfaces(SRC) based upon a vapor pressure of 40 mm Hg(1).

Non-Human Toxicity Excerpts · 5건

/LABORATORY ANIMALS: Acute Exposure/ 6 male Sprague-Dawley rats were exposed for 18 minutes to a concentration of 159.7 g/cu m. This exposure caused laboured breathing within less than 2 minutes, weakness, convulsions, collapse and death in 10 minutes. All animal died within 18 minutes.

/LABORATORY ANIMALS: Acute Exposure/ In a Russian study ..., acute inhalation exposure of rats to lethal or near lethal concentrations of phosphorus oxychloride resulted in immediate signs of irritation (rubbing of faces and restlessness). At 5-15 minutes of exposure, the rats exhibited inactivity and decreased respiration, followed by convulsions. Rats that survived showed continued lacrimation and corneal opacities, and ulcers around the mouth several days after cessation of exposure. The report provided a "threshold concentration" of 0.006 mg/L (0.96 ppm) based upon "integrated characteristics". It is unclear as to what effect this threshold pertains or the precise nature of the "integrated characteristics". Although no further details were provided, information in this report affirms the irritation and lethal capacity of phosphorus oxychloride following acute inhalation exposure.

/LABORATORY ANIMALS: Acute Exposure/ The results of an inhalation study in rats were /reported/. Groups of male Sprague-Dawley rats (number not provided) were exposed for 18 minutes to 159.7 mg phosphorus oxychloride/L (25,462 ppm). Conditions in the 35-L chamber were: 25 °C, 85% humidity, and 4.0 L/minute airflow. The concentration of the test material was such that there was a fog in the chamber. Within two minutes the rats /were/ having difficulty breathing and their eye/s/ were closed. At 10 minutes, weakness, convulsions, and collapse were observed, and one rat died. At 18 minutes all rats were dead. Necropsy revealed lung congestion. No further details were provided.

/LABORATORY ANIMALS: Acute Exposure/ Experiments using groups of 10 male guinea pigs /were also conducted/. The experimental protocol was the same as that described for the experiments with rats. Like the rats, the response of the guinea pigs was consistent with exposure to an irritating chemical (restlessness, lacrimation, pawing at nose and head). The 4-hr LC50 was 52.5 umole/mole of air (numerically equivalent to 52.5 ppm). Deaths occurred within 48 hours after exposure; no further details were provided. Neutralization of the phosphorus oxychloride with ammonia resulted in a lowering of the LC50 to 41.3 umole/mole of air (numerically equivalent to 41.3 ppm). Similar to the results observed for rats, the simultaneous exposure of the guinea pigs to ammonia was thought to decrease the irritation responses to the phosphorus oxychloride exposure but to increase the overall toxicity. The series of exposures and the respective responses used to obtain the median lethal concentration were not provided and, therefore, no other exposure-response data are available.

For more Non-Human Toxicity Excerpts (Complete) data for PHOSPHORUS OXYCHLORIDE (11 total), please visit the HSDB record page.

규제 정보

CERCLA Reportable Quantities · 2건

Persons in charge of vessels or facilities are required to notify the National Response Center (NRC) immediately, when there is a release of this designated hazardous substance, in an amount equal to or greater than its reportable quantity of 1000 lb or 454 kg. The toll free number of the NRC is (800) 424-8802. The rule for determining when notification is required is stated in 40 CFR 302.4 (section IV. D.3.b).

Releases of CERCLA hazardous substances are subject to the release reporting requirement of CERCLA section 103, codified at 40 CFR part 302, in addition to the requirements of 40 CFR part 355. Phosphorus oxychloride is an extremely hazardous substance (EHS) subject to reporting requirements when stored in amounts in excess of its threshold planning quantity (TPQ) of 500 lbs.

Clean Water Act Requirements · 1건

Phosphorus oxychloride is designated as a hazardous substance under section 311(b)(2)(A) of the Federal Water Pollution Control Act and further regulated by the Clean Water Act Amendments of 1977 and 1978. These regulations apply to discharges of this substance. This designation includes any isomers and hydrates, as well as any solutions and mixtures containing this substance.

DHS Chemicals of Interest (COI) · 6건

Phosphorus oxychloride

1

5000

80

220

A Commercial Grade

안전 데이터

OEB
C
OEL
TWA: 0.1 ppm (0.6 mg/m3), STEL: 0.5 ppm (3 mg/m3)
wgk
1
tsca
TSCA listed
rtecs
TH4897000
ridadr
UN 1810 (PHOSPHORUS OXYCHLORIDE)
HS 번호
28121020
risk_code
14-22-26-29-35-48/23-25
hazard_code
T+,C
safety_code
26-45-7/8-36/37/39
포장분류
I
위험 등급
6.1
기존화학 물질
KE-28728
F 고인화성물질
19-21
Hazard Classifications
Acute Tox. 2 InhalationAcute Tox. 4 OralEye Dam. 1Skin Corr. 1STOT RE 1 Inhalation
스토리지 클래스
6.1A - Combustible, acute toxic Cat. 1 and 2very toxic hazardous materials
유해 물질 데이터
10025-87-3(Hazardous Substances Data)
함량 및 규제정보
물질구분: 유독물질; 혼합물(제품)함량정보: 옥시염화 인 및 이를 25% 이상 함유한 혼합물
유해화학물질 필터링
97-1-218
중점관리물질 필터링
별표1-143
사고대비 물질 필터링
54

In 1995 the phosphoryl trichloride manufacturing capacities were about 39 900 tonnes in the USA, 100 000 tonnes in Western Europe, and 30 000 tonnes in Japan. The phosphoryl trichloride consumption of the USA increased from 24 300 tonnes in 1983 to about 30 700 tonnes in 1994.

For more U.S. Production (Complete) data for PHOSPHORUS OXYCHLORIDE (9 total), please visit the HSDB record page.

Consumption Patterns · 5건

52% AS A CHEM INT FOR TRICRESYL, CRESYL DIPHENYL, AND TRIPHENYL PHOSPHATES (GASOLINE ADDITIVES AND PLASTICIZERS); 20% AS A CHEM INT FOR OTHER CYCLIC PHOSPHATE ESTERS; 15% AS A CHEM INT FOR ACYCLIC PHOSPHATE ESTERS; 13% FOR MISC USES (1972).

DERIVATIVE: AROMATIC PHOSPHATE ESTERS, 60%; ALIPHATIC PHOSPHATE ESTERS, 30%; MISC & PESTICIDES 10% (1984 ESTIMATE).

CHEMICAL PROFILE: Phosphorus Oxychloride. Phosphate esters (flame retardants and plasticizers for plastics and urethanes, 55%; functional fluids, 30%; other esters, 15%) 80%; others, including pesticides and lube oil additives, 20%.

CHEMICAL PROFILE: Phosphorus Oxychloride. Demand: 1987: 31,300 tons; 1988: 32,000 tons; 1992: 34,000 tons /projected/ (Foreign trade is negligible).

For more Consumption Patterns (Complete) data for PHOSPHORUS OXYCHLORIDE (13 total), please visit the HSDB record page.

Consumer UsesFlame retardant
Industry UsesIntermediate
Methods of Manufacturing · 5건

It can be produced industrially either batchwise or in a continuous process. A finely divided stream of oxygen is reacted with phosphorus trichloride until the freezing point of the product is 1 °C. The reaction is accelerated by carrying it out under pressure. The presence of orthophosphoric acid has a catalytic effect, but traces of metallic impurities such as copper and cobalt, or of sulfur compounds, decrease the reaction rate. In a Hoechst process, phosphorus trichloride and oxygen are passed in concurrent through a stainless steel water-cooled packed column. The oxidation process, i.e., the uptake of oxygen, can be followed by the characteristic temperature changes. The first product, which leaves the column at a maximum temperature of 35 °C, has a freezing point of about 0.9 °C, and is taken from the top of the column into a second column where it is again treated with oxygen. This procedure avoids large temperature increases. The excess oxygen leaving the plant passes through a cold trap where entrained phosphoryl chloride is condensed out and recovered. The off-gas is then scrubbed with water. Commercial phosphoryl chloride contains about 99.5% phosphoryl chloride and traces of phosphorus trichloride.

OXIDATION OF PHOSPHORUS TRICHLORIDE.

From phosphorus trichloride, phosphorus pentoxide, and chlorine

Phosphorus oxychloride has been manufactured by oxidizing phosphorus trichloride. When oxygen is bubbled through liquid phosphorus trichloride, complete absorption of pure oxygen is effected in a 1-m depth. When there is good heat exchange, the rate of oxygen absorption remains practically constant until only 3 -5 wt % of phosphorus trichloride remains in the oxychloride. The reaction is inhibited by impurities, especially iron and copper, sulfur compounds, or certain impurities from Cl2 production process. If these impurities are present, the reaction rate between phosphorus trichloride and oxygen exhibits an induction period, and then increases to a maximum, after which it falls steadily as the reaction proceeds. A small amount of dissolved phosphorus in the phosphorus trichloride does not influence the reaction.

For more Methods of Manufacturing (Complete) data for PHOSPHORUS OXYCHLORIDE (7 total), please visit the HSDB record page.

Formulations/PreparationsGRADES: TECHNICAL; 99.999+%.
General Manufacturing Information · 3건

Pesticide, Fertilizer, and Other Agricultural Chemical Manufacturing

Phosphoric trichloride: ACTIVE

/The Chemical Weapons Convention (CWC) is an international treaty which bans the development, production, stockpiling, and transfer or use of chemical weapons. The Convention mandates the destruction and prohibition of chemical weapons and related facilities and provides for restrictions on international trade in toxic chemicals and precursors./ The Convention's monitoring and verification measures involve submission of declarations regarding ... /Schedule 1, 2, and 3 chemicals/ and inspections by the Organization for the Prohibition of Chemical Weapons of the facilities where these chemicals are produced. ... Schedule 3 chemicals ... /may/ have been stockpiled or used as weapons, but ... are produced /and used/ in large quantities for purposes not prohibited by the Convention (2). Phosphorus oxychloride is listed in the CWC Annex on Chemicals under Schedule 3 (1).

응용 분야 · 2건

용도디 페닐 이소 옥틸 포스페이트 및 트리 에틸 포스페이트, 플라스틱 가소제, 유기 인계 농약 및 장시간 작용하는 술폰 아미드와 같은 포스 파 시드의 제조에 사용됩니다. 또한 염료 중간체, 염소화 제 및 촉매, 난연제의 유기 합성으로 사용할 수 있습니다. 태양 에너지 산업, 집적 회로, 분리 장치, 조립식 막대 및 기타 액체 인 공급원에서 전자 등급 tricloxane을 사용하여 인산염을 제조 할 수도 있습니다. 반도체 산업에서 주로 N 형 도핑 소스에 사용되며 0 ℃에서 반응 효과가 가장 좋습니다.

용도Phosphorus oxychloride is an important intermediate in the production of triarylphosphate esters (e.g., triphenyl phosphate and tricresyl phosphate), which have been used as flame retardants and plasticizers for PVC. It is acutely toxic to the eyes, throat, and respiratory tract. Phosphorus oxychloride is also used in nuclear reprocessing, as chlorinating agent, especially to replace oxygen in organic compounds, as solvent in cryoscopy and the semiconductor industry.

제조 방법 · 1건

Phosphorus oxychloride can be prepared from phosphorus trichloride or phosphorus pentachloride. It can be obtained from phosphorus trichloride by cautious addition of potassium chlorate:3PCl3 + KClO3 → 3POCl3 + KCl The oxychloride also is obtained by the action of boric acid or oxalic acid with phosphorus pentachloride: 3PCl5 + 2B(OH)3 → 3POCl3 + B2O3 + 6HCl PCl5 + (COOH)2 → POCl3 + CO + CO2 + 2HCl Phosphorus oxychloride also is made by heating calcium phosphate in a current of chlorine and carbon monoxide at 350°C: 2Ca3(PO4)2 + 9Cl2 + 6CO → 4POCl3 + 6CaCO3 Alternatively, heating a mixture of calcium phosphate and carbon in a current of chlorine at 750°C yields the oxychloride.

상·하류 제품 정보

상류 원료

Distillation equipment이산화 황염소(기체)산소, 냉각된 액체인 펜타염화물삼염화 인Dilute hydrochloric acid황린해사

하류 제품

2,4-Dichlorothieno[3,2-d]pyrimidineDICAPTHON2,2'-비티오펜-5-카르복스알데하이드5-Methyl-2-methylsulfanyl-pyrimidine벤잘데하이드질소머스타드2-Trifluoromethylbenzylsulfonyl chloride4,6-Dichloro-5-methoxypyrimidine2-클로로-4-메틸퀴놀린-3-탄소니트릴4-(4-(Bis-(2-chloroethyl)amino)benzylidene-2-phenyl-oxazoline-5-oneHexafluoroglutaric anhydride6-N-헥실아미노퓨린2,4-Dichlorothieno[3,2-d]pyrimidine히드록시프로필 디스타치 인산염2,6-디클로로-4,8-디피페리디노피리미디노[5,4-d]피리미딘2,4-Dichloro-5-nitropyrimidineP-니트로페닐 인산, 디나트륨 염, 헥사수화물살리실산4-TERT-부틸페닐에스테르트리옥틸 인산염2-Ethoxy-1-naphthaldehyde클로르암부실4-Chloro-7-azaindole염기성청색7호2-(클로로메틸)-5-프로폭시피리딘Niclosamide2-Chloro-4-methylpyrimidine4-클로로-3,5-디니트로벤즈알데히드6-Chloro-5-cyano-4-methoxymethyl-3-nitro-2-picoline2-클로로-3',4'-디하이드록시아세토페논2,4,6-Trichloropyridine다이스타치포스페이트Quinazoline, 2-methyl- (6CI,7CI,8CI,9CI)Acetylated Dishtarch PhosphatePyridine-3-sulfonyl chloride hydrochloride4-(Dimethylamino)benzophenone2-클로로-5-티오펜카르복스알데히드P-톨릴-아세틸클로라이드Chromone-3-carboxaldehyde3-클로로-1H-인다졸4-Trifluoromethylbenzylsulfonyl chloride2-Chlorolepidine
추가 설명 · 1건

정의A white crystalline solid. It is a monobasic acid forming the anion H2PO2 – in water. The sodium salt, and hence the acid, can be prepared by heating yellow phosphorus with sodium hydroxide solution. The free acid and its salts are powerful reducing agents.