Boron trifluoride dimethyl etherate
353-42-4COC.FB(F)FKTPWETRNSUKEME-UHFFFAOYSA-NBoron trifluoride dimethyl etherate appears as a fuming liquid. Corrosive to skin, eyes and mucous membranes. May be toxic by inhalation. Used as a catalyst in chemical reactions.
353-42-4Metals -> Metalloid Compounds (Boron)
Corrosives
1.239
1.239 @25 °C
258.8 °F at 760 mmHg (EPA, 1998)
126-127 °C
When heated to decomposition it emits toxic fumes of /hydrogen fluoride/.
The toxic action of the halogenated borons is considerably influenced by their decomposition products (hydrofluoric acid-, fluoboric acid-, hydrochloric acid-). /Halogenated borons/
-14 °C
-14 °C
17.3 [mmHg]
20 [mm Hg] @25 °C
Boron trifluoride dimethyl etherate appears as a fuming liquid. Corrosive to skin, eyes and mucous membranes. May be toxic by inhalation. Used as a catalyst in chemical reactions.
안전 정보는 참고용이며, 공급업체의 물질안전보건자료(SDS), 관련 법규 및 전문가 평가를 대체하지 않습니다.
Danger
H260 (100%): In contact with water releases flammable gases which may ignite spontaneously [Danger Substances and mixtures which in contact with water, emit flammable gases]
P223, P231+P232, P260, P261, P264, P264+P265, P270, P271, P280, P301+P317, P301+P330+P331, P302+P335+P334, P302+P361+P354, P304+P340, P305+P354+P338, P316, P317, P319, P321, P330, P363, P370+P378, P402+P404, P405, and P501 (click each P-code to see the statement)
Aggregated GHS information provided per 155 reports by companies from 4 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.
Chemical: Boron, trifluoro[oxybis[methane]]-, (T-4)-
REACH registered substance: Dimethyl ether-boron trifluoride (EC: 206-532-1)
Boron, trifluoro[oxybis[methane]]-, (T-4)-: HSNO Approval: HSR001267 Approved with controls
The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)
Fire may produce irritating or poisonous gases. Flammable/combustible material which may be ignited by heat spark or flame. Vapors may travel to a source of ignition and flash back. Container may explode in heat of fire. Vapor explosion hazard indoors, outdoors, or in sewer. Runoff to sewer may create fire or explosion hazard. When heated to decomposition, it emits toxic fumes of fluorides. (EPA, 1998)
· Produce flammable and toxic gases on contact with water.
Boron trifluoride ethers are effective reagents used as a source of boron trifluoride in the production of semiconductors and organic compounds; [ACGIH] Used as an esterification reagent for fats and oils; in breeder reactor control rods; [HSDB] Used as a catalyst in chemical reactions; [CAMEO]
A multistage exchange-distillation of boron trifluoride-dimethyl ether complex is used in boron isotope production /for use in breeder reactor control rods/
Esterification reagent for fats and oils.
용도Reactant or reagent involved in:Deconvoluting the chemical reaction kinetics of platinum-silver ligand exchangeSynthesis of neurogenic ganglioside LLG-3 from starfish via glycosylation reactionsSynthesis of peloruside via lactonization and relay ring-closing metathesis cyclizationFRET for monitoring Pd-catalyzed nucleophilic allylic substitution reactionsSingle molecuel imaging of fluorophore-tagged palldium(II) complexesβ-elimination and rearrangement reactions for synthesis of exocyclic vinyl ethers
일반 설명A fuming liquid. Corrosive to skin, eyes and mucous membranes. May be toxic by inhalation. Used as a catalyst in chemical reactions.
Fuming liquid; [CAMEO] Stable but highly flammable, brown liquid; [ACGIH]
clear brownish liquid, fuming in moist air
This material is highly toxic by inhalation. (EPA, 1998)
· Highly toxic: contact with water produces toxic gas, may be fatal if inhaled.
TLV Basis = respiratory tract irritation and pneumonitis; Boron trifluoride is the key toxic exposure for workers handling or producing these materials. Reacts exothermically with water to release highly flammable ethers and corrosive boron trifluoride hydrates; [ACGIH] Corrosive to the skin; [Quick CPC] A strong skin, eye, and respiratory tract irritant; [HSDB] Very toxic by inhalation; [CAMEO] Reacts violently with water; [MSDSonline] See Boron trifluoride.
[40 CFR 261.32; U.S. National Archives and Records Administration's Electronic Code of Federal Regulations. Available from: http://www.gpoaccess.gov/ecfr as of December 15, 2004)] D003; A solid waste containing Boron Trifluoride Dimethyl Etherate may become characterized as a hazardous waste when subjected to testing for reactivity as stipulated in 40 CFR 261.23, and if so characterized, must be managed as a hazardous waste.
Wear self-contained, positive- pressure breathing apparatus and full protective clothing. Move containers from fire area if possible. Do not get water inside containers. Spray cooling water on containers that are exposed to flame until well after fire is out. Withdraw immediately in case of rising sound from venting safety device or any discoloration of tank due to fire. Isolate for 1/2 mile in all directions if tank car or truck is involved in fire.
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.
Warning: This material is highly toxic by inhalation.
General First Aid:
Environmental considerations: land spill: Dig a pit, pond, lagoon, holding area to contain liquid or solid material. Dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete. Absorb bulk liquid with fly ash, cement powder, or commercial sorbents.
Environmental considerations: water spill: Use natural barriers or oil spill control booms to limit spill travel. use natural deep water pockets, excavated lagoons, or sand bag barriers to trap material at bottom.
SRP: The most favorable course of action is to use an alternative chemical product with less inherent propensity for occupational exposure or environmental contamination. Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in soil or water; effects on animal, aquatic, and plant life; and conformance with environmental and public health regulations.
If material not on fire and not involved in fire: Do not use water. Keep sparks, flames, and other sources of ignition away. Keep material out of water sources and sewers. Keep material dry.
Personnel protection: Avoid breathing vapors. Keep upwind. Avoid bodily contact with the material. Do not handle broken packages unless wearing appropriate personal protective equipment.
Excerpt from ERG Guide 139 [Substances - Water-Reactive (Emitting Flammable and Toxic Gases)]:
Immediate precautionary measure
When spilled in water
When spilled in water
0.1 [ppm], as BF3
0.7 [ppm]
Ceiling Limit: 1 ppm. /Boron trifluoride/
8 hr Time Weighted Avg (TWA): 2.5 mg/cu m). /Fluorides, as F/
Excursion Limit Recommendation: Excursions in worker exposure levels may exceed 3 times the TLV-TWA for no more than a total of 30 minutes during a work day, and under no circumstances should they exceed 5 times the TLV-TWA, provided that the TLV-TWA is not exceeded. /Fluorides, as F/
A4; Not classifiable as a human carcinogen. /Fluorides, as F/
Initial Medical Examination: ... Respiratory system and kidneys should be stressed. The skin and eyes should be examined for evidence of chronic disorders. Surveillance of the lung is indicated. ... Examinations should be repeated on an annual basis. /Boron trifluoride/
Placement examinations should include a physical examination giving particular attention to the respiratory system and using appropriate pulmonary function tests such as FEV, and FVC. /Boron trifluoride/
A complete history and physical examination: The purpose is to detect pre-existing conditions that might place the exposed employee at increased risk, and to establish a baseline for future health monitoring. Examination of the respiratory system and kidneys should be stressed. The skin and eyes should be examined for evidence of chronic disorders. 14" x 17" chest roentgenogram Surveillance of the lungs is indicated. FVC and FEV (1 sec): Boron trifluoride is a severe pulmonary irritant in animals. Persons with impaired pulmonary function may be at increased risk from exposure. Periodic surveillance is indicated. The aforementioned medical examinations should be repeated on an annual basis, except that an x-ray is necessary only when indicated by the results of pulmonary function testing, or when signs and symptoms of respiratory disease occur. /Boron trifluoride/
Fluoride levels in urine should be checked periodically. /Fluoride and cmpd/
No specific considerations are needed for boric acid or borates except for general health and liver and kidney function. /Boric acid and borates/
/HUMAN EXPOSURE STUDIES/ A description of effects on 78 workers exposed from 10 to 15 yr to boron trifluoride, as reported in a USSR abstract, consisted of complaints of dryness and bleeding of nasal mucosa, bleeding gums, dry and scaly skin, and pain in joints. ...No specific... concentrations were reported... and... there was /also/ concurrent exposure to ethylene and isobutyl with no reported concentrations... . /Boron trifluoride/
/HUMAN EXPOSURE STUDIES/ In... manufacturing plant in USA, physical exams initiated in 1974 for small group workers including 7 with present and 6 with past exposures to boron trifluoride or other fluoride, ranging from 1 to 27 yr. Five of the 7 currently exposed, and 3 of 6 with previous exposures showed lower pulmonary function (forced VC and FEV) than predicted for normal population. Lowered pulmonary function was severe in 1, moderate in 3, and minimal in 1 of 7 currently exposed who had average exposure of 13 yr. X-rays were negative, and no urinary fluorine concentrations were above acceptable preshift concentration of 4 mg/L. /Boron trifluoride/
/HUMAN EXPOSURE STUDIES/ /CNS depressant/ effects in man may be seen at concentrations of 5 to 10% in air.
/SIGNS AND SYMPTOMS/ Initial symptoms from ingestion /include/ ... salivation, nausea, abdominal pain, vomiting, and diarrhea. ... The patient shows signs of increased irritability of the nervous system, including paresthesias, a positive Chvostek sign, hyperactive reflexes, and tonic and clonic convulsions. ... Hypocalcemia and hypoglycemia are frequent lab finding. ... Pain in various muscle groups ... blood pressure falls ... due to central vasomotor depression as well as direct toxic action on cardiac muscle. The respiratory center is first stimulated and later depressed. Death ... from either respiratory paralysis or cardiac failure. /Fluoride salts/
For more Human Toxicity Excerpts (Complete) data for BORON TRIFLUORIDE DIMETHYL ETHERATE (7 total), please visit the HSDB record page.
/LABORATORY ANIMALS: Subchronic or Prechronic Exposure/ Intraperitoneal doses of 5 mg/kg produced reversible anesthesia in mice. In animals 85% in air produced profound anesthesia with a gradual cessation of respirations. About 20 minutes were required for recovery after 50 minutes of anesthesia. No harmful effects were noted in rabbits exposed to 2000 ppm in air for 1.25 hours twice daily for 13 weeks of 5 exposure-days each. Sometimes encountered as a mole-per-mole complex with boron trifluoride which is said to be a severe pulmonary irritant.
/LABORATORY ANIMALS: Subchronic or Prechronic Exposure/ Boron trifluoride gas is a severe irritant of the lungs, eyes and skin. Exposure of six animal species to 100 ppm, 4 to 7 hours/day, 5 days/week in a 30 day experiment killed all animals, most within the test period. Guinea pigs were the most susceptible, with 40 dead in two days. Dogs were the least susceptible, all dying after the test period. The primary site of damage was the lung, with severe irritation leading to death by pneumonia. Kidney damage, leading to nephritis, also occurs. Morbidity and mortality at lower levels of exposure were proportionate to the concentration time. Bronchitis, kidney damage, retarded growth, and fibrosis of teeth and bone occur in surviving animals. Exposure of 6 animal species to 100 ppm for 30 days resulted in a high mortality rate. Exposure of animals to a concentration of 42 mg/cu m (approximately 15 ppm) for an unspecified time period was fatal in some cases; autopsy findings were pneumonitis and degenerative changes in the renal tubules. Repeated exposure of mice to 15 ppm for 30 days resulted in mortality of 19% due to pulmonary irritation; rats similarly exposed for 2 weeks developed hypoplasia of the teeth and deposition of fluoride up to 25 times normal levels, both in the incisors and in femoral epiphyses. Three species of animals repeatedly exposed to levels of 12.8, 7.7, or 3 ppm for periods up to 6 months developed pneumonitis and evidence of dental fluorosis; high concentrations caused deaths in guinea pigs. /Boron trifluoride/
If strong concentrations of boron trifluoride gas get into the eyes, wash eyes immediately with large amounts of water, lifting the lower and upper lids occasionally. Get medical attention immediately. Contact lenses should not be worn when working with this chemical. /Boron trifluoride/
If strong concentrations of boron trifluoride gas contact the skin, immediately flush the contaminated skin with water. If strong concentrations of boron trifluoride gas penetrate through the clothing, remove the clothing immediately and flush the skin with water. If irritation persists after washing, get medical attention. /Boron trifluoride/
If a person breathes in large amounts of boron trifluoride, move the exposed person to fresh air at once. If breathing has stopped, perform artificial respiration. Keep the affected person warm and at rest. Get medical attention as soon as possible. /Boron trifluoride/
Move the affected person from the hazardous exposure. If the exposed person has been overcome, notify someone else and put into effect the established emergency rescue procedures. Do not become a casualty. Understand the facility's emergency rescue procedures and know the locations of rescue equipment before the need arises. /Boron trifluoride/
For more Antidote and Emergency Treatment (Complete) data for BORON TRIFLUORIDE DIMETHYL ETHERATE (11 total), please visit the HSDB record page.
[40 CFR 261.32; U.S. National Archives and Records Administration's Electronic Code of Federal Regulations. Available from: http://www.gpoaccess.gov/ecfr as of December 15, 2004)] D003; A solid waste containing Boron Trifluoride Dimethyl Etherate may become characterized as a hazardous waste when subjected to testing for reactivity as stipulated in 40 CFR 261.23, and if so characterized, must be managed as a hazardous waste.
Releases of CERCLA hazardous substances are subject to the release reporting requirement of CERCLA section 103, codified at 40 CFR part 302, in addition to the requirements of 40 CFR part 355. Boron trifluoride dimethyl etherate is an extremely hazardous substance (EHS) subject to reporting requirements when stored in amounts in excess of its threshold planning quantity (TPQ) of 1,000 lbs.
Boron trifluoride compound with methyl ether (1:1)
1.00
15,000
Toxic chemical that can be released at a facility.
(CA) CALIFORNIA 1000 ug/L /Boron/
(NH) NEW HAMPSHIRE 630 ug/L /Boron/
(ME) MAINE 1,400 ug/L /Boron/
(MN) MINNESOTA 1,000 ug/L /Boron/
(WI) WISCONSIN 960 ug/L /Boron/