홈MCP워크벤치Skills
홈워크벤치알림마이페이지
Huagongshe 오픈 프로젝트:[email protected]AI 접속: llms.txt · MCP 가이드개인정보처리방침 · 이용약관 · 지원v1.7.8
  1. 홈
  2. /화합물

수산화 세슘

Cesium hydroxide

HCID 62750
노트반응
기본 정보개요이름 및 식별자물성안전 및 규제화학 및 산업관련 반응화합물 노트
부분 구조 검색유사 구조 찾기

기본 정보

CAS
21351-79-1
표준 SMILES
[Cs+].[OH-]
InChIKey
HUCVOHYBFXVBRW-UHFFFAOYSA-M
분자식
CsHO
평균 분자량
149.913 g/mol
단동위원소 질량
149.90819155

개요

Cesium hydroxide is a colorless to yellow crystalline solid. Harmful to skin and eyes. Used in electric storage batteries.

이름 및 식별자

우선 이름
Cesium hydroxide
IUPAC
cesium hydroxide
현지명
수산화 세슘
영어명
Cesium hydroxide
분자식
CsHO
분자량
149.91

이름 및 동의어

Cesium hydroxide21351-79-1Caesium hydroxide12182-83-1Cesium hydroxide (Cs(OH))UN2681UN2682EINECS 244-344-1458ZFZ6235NSC 121987UNII-458ZFZ6235HSDB 7906
이름 더 보기
세슘하이드록시드수산화세슘세슘 수산화물CsOHCaesium hydoxideCesiumhydroxide,50%aqueoussolution(99.9%-Cs)Cesium hydoxidecesiumhydroxidedimerCaesium Hydroxide 99.9%cesiumhydroxide(cs(oh))
NSC-121987CESIUM HYDROXIDE [MI]DTXSID7066699CHEBI:33988EC 244-344-1Cesium hydroxide dimerCaesium hydrateRefChem:124639

데이터베이스 식별자

CAS
21351-79-1、35103-79-8
PubChem CID
62750
DTXSID
DTXSID7066699
ChEBI
CHEBI:33988
UNII
458ZFZ6235
EC Number
244-344-1
Nikkaji
J95.210I

물성

구조 계산 물성

극성 표면적
1 Ų
수소 결합 공여자 수
1
수소 결합 수용자 수
1
회전 가능 결합 수
0
무거운 원자 수
2
형식 전하
0
복잡도
2

실험 및 물리화학적 성질

Chemical Classes · 2건

Other Classes -> Bases

Corrosives

pHStrong alkaline reaction. The strongest base known
Density · 6건

3.68 (NIOSH, 2024) - Denser than water; will sink

3.68 g/cu cm

3.68 g/cm³

3.68

3.675 @25 °C

3.68

Color/Form · 2건

White-yellow hygroscopic crystals

Colorless or yellowish, fused, crystalline mass

Solubility · 6건

395 % at 59 °F (NIOSH, 2024)

Soluble in ethanol

Soluble in about 25 parts water, much heat being evolved

300 g/100 g water at 30 °C

Solubility in water, g/100ml at 15 °C: 395 (very good)

(59 °F): 395%

CorrosivityCorrosive
DecompositionHazardous decomposition products formed under fire conditions. - Cesium/cesium oxides.
Melting Point · 6건

522 °F (NIOSH, 2024)

342.3 °C

MP: 272.3 °C

272 °C

522 °F

315 °C

Vapor Pressure · 3건

안전 및 규제

안전 정보는 참고용이며, 공급업체의 물질안전보건자료(SDS), 관련 법규 및 전문가 평가를 대체하지 않습니다.

GHS 분류

GHS Classification · 6건

Danger

H302 (97.8%): Harmful if swallowed [Warning Acute toxicity, oral]

P203, P260, P264, P264+P265, P270, P280, P301+P317, P301+P330+P331, P302+P361+P354, P304+P340, P305+P354+P338, P316, P317, P318, P319, P321, P330, P363, P405, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 225 reports by companies from 10 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Warning

H361: Suspected of damaging fertility or the unborn child [Warning Reproductive toxicity]

유해성 정보

Regulatory Information · 6건

Chemical: Cesium hydroxide (Cs(OH))

Chemical: Cesium hydroxide, monohydrate

Cesium hydroxide (Cs(OH)) is listed on the EPA's Chemical Data Reporting (CDR) system. Manufacturers and importers of Cesium hydroxide (Cs(OH)) are required to report information about their production and use of this chemical to the EPA under the Toxic Substances Control Act (TSCA). (40 eCFR Part 711)

Status: Active Update: 21-03-2023 https://echa.europa.eu/registration-dossier/-/registered-dossier/10282

Caesium hydroxide: Does not have an individual approval but may be used under an appropriate group standard

The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)

Other Safety Information · 2건

Evaluation - Cesium salts

Evaluation - Cesium salts

DOT Label · 2건

Corrosive

Corrosive

Fire Hazards · 6건

Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

화학 및 산업

용도 및 제조

Uses · 4건

Used as a polymerization catalyst; also used in photography and in electrolyte solutions for storage batteries; [HSDB]

Battery Manufacturing [Category: Industry]

Polyols are important raw materials for the production of polyurethane foams. Their synthesis profits from use of cesium hydroxide as base catalyst. In polyol synthesis isomerization of the starting material propylene oxide is an adverse side reaction eventually leading to chain termination in the polymerization with polyisocyanate. The tendency of polyols to undergo isomerization is minimized when using cesium hydroxide, as isomerization tendency decreases in the order Li > Na > K > Rb > Cs.

Recommended as electrolyte in alkaline storage batteries at subzero temperatures, polymerization catalyst for siloxanes.

U.S. Production2023: <50,000 lb
Industry UsesIntermediate
Methods of Manufacturing · 2건

Alkaline decomposition can be carried out either by mixing /powdered pollucite/ ore with lime and calcium chloride and heating to 800 - 900 °C followed by leaching of the residue or by heating pollucite with sodium chloride and soda ash to 600 - 800 °C followed by leaching. Both processes furnish impure solutions of cesium chloride. Hydrothermal alkaline leaching with Ca(OH)2 at 200 - 280 °C under high pressure has been developed as an industrial process to yield a low-purity cesium hydroxide directly from pollucite.

By adding barium hydroxide to an aqueous solution of cesium sulfate.

Formulations/Preparations · 2건

Prepared by electrolysis of Cs salts

Grade: Technical, 50% aqueous solution.

General Manufacturing Information · 3건

All Other Basic Inorganic Chemical Manufacturing

Cesium hydroxide (Cs(OH)): ACTIVE

If cesium is exposed to air, explosion-like oxidation to form cesium superoxide ... occurs; contact with water results in a vigourous reaction to form cesium hydroxide and hydrogen gas, which may ignite spontaneously

관련 반응

27건
반응 기록 만들기
HRID 234564 반응식
HRID 234564반응물로uspto-grants-1997_01
HRID 355612 반응식
HRID 355612반응물로uspto-grants-1998_11
HRID 365236 반응식
HRID 365236반응물로uspto-grants-2000_10
HRID 858193 반응식
HRID 858193반응물로uspto-grants-2006_12
HRID 885017 반응식
HRID 885017반응물로uspto-grants-2012_08
HRID 903520 반응식
HRID 903520반응물로uspto-grants-1980_10
HRID 1039548 반응식
HRID 1039548반응물로uspto-grants-2013_10
HRID 1053560 반응식
HRID 1053560반응물로uspto-grants-2016_07
1 / 4 페이지

화합물 노트

불러오는 중…

이 페이지에서기본 정보개요이름 및 식별자물성안전 및 규제화학 및 산업관련 반응화합물 노트

0 mmHg (approx) (NIOSH, 2024)

0 mmHg (approx)

0 mmHg (approx)

Physical Description · 6건

Cesium hydroxide is a colorless to yellow crystalline solid. Harmful to skin and eyes. Used in electric storage batteries.

Cesium hydroxide, solution appears as an aqueous solution. Strongly corrosive. Harmful to skin and eyes. Used in electric storage batteries.

Liquid

Colorless or yellowish, crystalline solid. Note: Hygroscopic (i.e., absorbs moisture from the air); [NIOSH]

COLOURLESS-TO-YELLOW HYGROSCOPIC CRYSTALS.

Colorless or yellowish, crystalline solid.

Other Experimental Properties · 2건

Very deliquescent

Colorless, crystalline, hygroscopic substance; mp 205-208 °C; density 3.5 g/cu cm; solubility 860 g/100 g water at 15 °C. The solution is a strong base and very caustic. /Cesium hydroxide monohydrate/

물리화학적 성질

녹는점
272 °C · 272 °C(lit.)
밀도
3.68 g/mL · 3.68 g/mL at 25 °C(lit.)
용해도
에탄올과 혼합 가능.
물리적 상태
액체
산도 계수 (pKa)
11.6 · 11.6[at 20 ℃]
색상
무색의
수용성
녹는
비열
0.47 J/ · Cp(crystal): 0.47 J/(g·K); Cp(gas): 0.33 J/(g·K), at 25℃
Merck
13 · 13,2022
안정성
안정적인. 산과 호환되지 않습니다. 공기 중 이산화탄소를 흡수합니다.
InChI
1S/Cs.H2O/h;1H2/q+1;/p-1
InChIKey
HUCVOHYBFXVBRW-UHFFFAOYSA-M
SMILES
[OH-].[Cs+]
NIST
Cesium hydroxide(21351-79-1)
EPA
Cesium hydroxide (21351-79-1)
화학적 성질 · 1건

Caesium hydroxide (CsOH) is a colorless-to-yellow crystalline compound that is commonly used in aqueous solution. It is a strongly hygroscopic base and rapidly corrodes the surfaces of semiconductor materials such as silicon. Although CsOH was once regarded as one of the strongest conventional bases, many compounds, including n-butyllithium, caesium hydride, and sodium amide, exhibit significantly greater protonic basicity than CsOH.

· Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes.

· Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes.

· Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes.

· Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes.

Health Hazards · 6건

Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

· TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death.

· TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death.

· TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury or death.

· TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury or death.

Hazards SummaryMay cause skin burns; [NIOSH] Reacts with water releasing corrosive gases; [CAMEO] Solutions may be corrosive, but a 5% solution was not irritating to animals; [CHEMINFO] See Cesium and Cesium, radioactive. See Sodium hydroxide.
DOT ID and Guide · 6건

2682 157

2682 157

2681 154

2681 154

2682 157

2681 154(solution)

Reactive Group · 2건

Bases, Strong

Bases, Strong

UN ClassificationUN Hazard Class: 8; UN Pack Group: II
RCRA RequirementsD002; A solid waste containing cesium hydroxide may become characterized as a hazardous waste when subjected to testing for corrosivity as stipulated in 40 CFR 261.22, and if so characterized, must be managed as a hazardous waste.
Reactivity Alerts · 2건

Water-Reactive

Known Catalytic Activity

Reactivity Profile · 2건

CESIUM HYDROXIDE neutralizes acids violently to form salts plus water. Reacts with certain metals (such as aluminum and zinc) to form oxides or hydroxides of the metal and generate gaseous hydrogen. May initiate polymerization reactions in polymerizable organic compounds, especially epoxides. May generate flammable and/or toxic gases with ammonium salts, nitrides, halogenated organics, various metals, peroxides, and hydroperoxides. May serve as a catalyst. Reacts when heated above about 84 °C with aqueous solutions of reducing sugars other than sucrose, to evolve toxic levels of carbon monoxide [Bretherick, 5th Ed., 1995].

CESIUM HYDROXIDE, SOLUTION neutralizes acids exothermically to form salts plus water. Reacts with certain metals (such as aluminum and zinc) to form oxides or hydroxides of the metal and generate gaseous hydrogen. May initiate polymerization reactions in polymerizable organic compounds, especially epoxides. May generate flammable and/or toxic gases with ammonium salts, nitrides, halogenated organics, various metals, peroxides, and hydroperoxides. May serve as a catalyst. Reacts when heated above about 84 °C with aqueous solutions of reducing sugars other than sucrose, to evolve toxic levels of carbon monoxide [Bretherick, 5th Ed., 1995].

안전 및 보호

Fire Fighting · 3건

Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

In case of fire in the surroundings, use appropriate extinguishing media. In case of fire: keep drums, etc., cool by spraying with water. NO direct contact with water.

First Aid Measures · 4건

Fresh air, rest. Half-upright position. Refer for medical attention.

Remove contaminated clothes. Rinse skin with plenty of water or shower. Refer for medical attention .

First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.

Rinse mouth. Do NOT induce vomiting. Give one or two glasses of water to drink. Refer for medical attention .

Accidental Release Measures · 6건

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.

First Aid · 6건

Excerpt from NIOSH Pocket Guide for Cesium hydroxide:

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

General First Aid:

General First Aid:

General First Aid:

General First Aid:

Safe StorageDry. Well closed. Separated from combustible substances, acids, strong oxidants, metals and food and feedstuffs.
Exposure Control and Personal Protection · 4건

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear positive pressure self-contained breathing apparatus (SCBA).

· Wear positive pressure self-contained breathing apparatus (SCBA).

Fire Fighting Procedures · 4건

Fires involving cesium hydroxide should be fought upwind and from the maximum distance possible. isolate the hazard area and deny access to unnecessary personnel. Emergency personnel should stay out of low areas and ventilate closed spaces before entering. Containers of cesium hydroxide may explode in the heat of the fire and should be moved from the fire area if it is possible to do so safely. If this is not possible, cool containers from the sides with water until well after the fire is out. Stay away from the ends of containers. Dikes should be sued to contain fire-control water for later disposal. Firefighters should wear a full set of protective clothing and self-contained breathing apparatus when fighting fires involving cesium hydroxide. Structural firefighters' protective clothing may provide limited protection against fires involving cesium hydroxide.

Use dry chemical, carbon dioxide, water spray, or standard foam to extinguish fires involving cesium hydroxide.

Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Special protective equipment for fire-fighters: Wear self contained breathing apparatus for fire fighting if necessary.

Storage Conditions · 4건

Cesium hydroxide should be stored in a cool, dry, well-ventilated area in tightly sealed containers that are labeled in accordance with OSHA's hazard communication standard. Cesium hydroxide should not be stored in glass containers. Containers of cesium hydroxide should be protected from physical damage and should be stored separately from acids, organic compounds, metals, oxygen, carbon dioxide, moisture, heat, sparks, and open flame. Because container that formerly contained cesium hydroxide may still hold product residues, they should be handled appropriately.

Cesium hydroxide must be stored in silver or platinum and out of contact with air because of its reactivity with glass and carbon dioxide.

Keep tightly closed

Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Store under inert gas.

Cleanup Methods · 3건

In the event of a spill or leak involving cesium hydroxide or a solution containing cesium hydroxide, persons not wearing protective equipment and clothing should be restricted from contaminated areas until cleanup is complete. The following steps should be undertaken following a spill or leak: 1. Do not touch the spilled material; stop the leak if it is possible to do so without risk. 2. Notify safety personnel. 3. Do not use water in clean-up. 4. For small dry spills, use a scoop or clean shovel and gently place the material into a clean, dry container, creating as little dust as possible; cover and remove the container form the spill area. 5. For liquid spills, dilute the contents of cesium hydroxide with water, neutralize the spilled material with dilute acid, absorb with sand or other noncombustible absorbent material, and place into closed containers for later disposal.

ACCIDENTAL RELEASE MEASURES. Personal precautions: Use personal protective equipment. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas.

ACCIDENTAL RELEASE MEASURES. Methods and materials for containment and cleaning up: Soak up with inert absorbent material and dispose of as hazardous waste. Keep in suitable, closed containers for disposal.

Nonfire Spill Response · 2건

Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:

Excerpt from ERG Guide 154 [Substances - Toxic and/or Corrosive (Non-Combustible)]:

Disposal Methods · 2건

SRP: The most favorable course of action is to use an alternative chemical product with less inherent propensity for occupational harm/injury/toxicity or environmental contamination. Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in soil or water; effects on animal and plant life; and conformance with environmental and public health regulations.

SRP: Wastewater from contaminant suppression, cleaning of protective clothing/equipment, or contaminated sites should be contained and evaluated for subject chemical or decomposition product concentrations. Concentrations shall be lower than applicable environmental discharge or disposal criteria. Alternatively, pretreatment and/or discharge to a permitted wastewater treatment facility is acceptable only after review by the governing authority and assurance that "pass through" violations will not occur. Due consideration shall be given to remediation worker exposure (inhalation, dermal and ingestion) as well as fate during treatment, transfer and disposal. If it is not practicable to manage the chemical in this fashion, it must be evaluated in accordance with EPA 40 CFR Part 261, specifically Subpart B, in order to determine the appropriate local, state and federal requirements for disposal.

Spillage Disposal · 1건

Personal protection: particulate filter respirator adapted to the airborne concentration of the substance. Personal protection: chemical protection suit. Sweep spilled substance into plastic or glass containers. Wash away remainder with plenty of water.

독성 정보

Target OrgansEyes, skin, respiratory system
Adverse EffectsDermatotoxin - Skin burns.
Exposure Routes · 2건

The substance can be absorbed into the body by ingestion.

inhalation, ingestion, skin and/or eye contact

Signs and Symptoms · 5건

Cough. Shortness of breath. Sore throat.

Skin burns.

Severe deep burns.

Abdominal pain. Burning sensation. Shock or collapse.

irritation eyes, skin, upper respiratory system; eye, skin burns

Human Toxicity Excerpts · 2건

/SIGNS AND SYMPTOMS/ In humans, cesium hydroxide is irritating and corrosive to the eyes, nose throat, and skin. Solutions containing 5% cesium hydroxide are regarded as safe for human skin contact; however in contact with the eyes, a solution of this concentration causes extreme irritation and corneal corrosion. Stronger solutions of cesium hydroxide cause eye and skin burns and may cause permanent damage.

/SIGNS AND SYMPTOMS/ The signs and symptoms of acute inhalation exposure to cesium hydroxide include a burning sensation in the nose, throat, and upper respiratory tract; runny nose; pain, redness and tearing of the eyes; difficult breathing; and redness, pain and burns of the skin.

Non-Human Toxicity Excerpts · 5건

/LABORATORY ANIMALS: Acute Exposure/ In an acute lethality study of rats, administration of cesium hydroxide or cesium iodide at dose levels up to 910 or 1,217 mg Cs/kg, respectively, resulted in stomach and intestinal hemorrhage, bloody fluid exudate within the peritoneal cavity, and adhesions of abdominal organs.

/LABORATORY ANIMALS: Acute Exposure/ Rats administered unspecified acute gavage doses of cesium hydroxide exhibited initial signs of hyperexcitability followed by apathy and weakness during the course of 14 days of observation after dosing

/LABORATORY ANIMALS: Acute Exposure/ A 5% solution of cesium hydroxide was extremely irritating and caustic to the rabbit eye. It is likely that this effect was the result of the caustic nature of the hydroxide rather than an effect due to cesium per se.

/LABORATORY ANIMALS: Acute Exposure/ A 5% solution of CsOH was irritating to intact skin of rabbits and extremely irritating to the abraded skin and to the eyes; and there was no evidence of cutaneous sensitization in treated guinea pigs.

/OTHER TOXICITY INFORMATION/ Gastrointestinal and respiratory effects noted in rats administered acute oral doses of cesium hydroxide may have been due to the alkaline properties of the compound rather than the biochemical behavior of cesium.

Antidote and Emergency Treatment · 3건

Immediate first aid: Remove patient from contact with the material. Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR if necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on the left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Inorganic Bases/Alkaline Corrosives and Related Compounds/

Basic treatment: Establish a patent airway (oropharyngeal or nasopharyngeal airway, if needed). Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 6 to 12 L/min. Monitor for pulmonary edema and treat if necessary ... . Monitor for shock and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with 0.9% saline (NS) during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 mL of water for dilution if the patent can swallow, has a strong gag reflex, and does not drool ... . Do not attempt to neutralize. Cover skin burns with dry sterile dressings after decontamination ... . /Inorganic Bases/Alkaline Corrosives and Related Compounds/

Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious, has severe pulmonary edema, or is in severe respiratory distress. Early intubation, at the first signs of upper airway obstruction, may be necessary. Positive-pressure ventilation techniques with a bag valve mask device may be beneficial. Consider drug therapy for pulmonary edema ... . Monitor cardiac rhythm and treat arrhythmias as necessary ... . Start IV administration of D5W /SRP: "To keep open", minimal flow rate/. Use 0.9% saline (NS) or lactated Ringer's (LR) if signs of hypovolemia are present. For hypotension with signs of hypovolemia, administer fluid cautiously. Consider vasopressors if patient is hypotensive with a normal fluid volume. Watch for signs of fluid overload ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Inorganic Bases/Alkaline Corrosives and Related Compounds/

Non-Human Toxicity Values · 4건

LD50 Rat ip 100 mg/kg

LD50 Rat oral 570 mg/kg

LD50 Rat intraperitoneal 100 mg/kg

LD50 Mouse oral 800 mg/kg

규제 정보

RCRA RequirementsD002; A solid waste containing cesium hydroxide may become characterized as a hazardous waste when subjected to testing for corrosivity as stipulated in 40 CFR 261.22, and if so characterized, must be managed as a hazardous waste.

안전 데이터

OEB
B
OEL
TWA: 2 mg/m3
wgk
3
tsca
TSCA listed
ridadr
UN 2682
독성
LD50 i.p. in rats: 100 mg/kg (Cochran)
HS 번호
28259090
risk_code
22-35-34
hazard_code
C
safety_code
26-36/37/39-45-37/39-27-28
포장분류
II
위험 등급
8
기존화학 물질
KE-05440
F 고인화성물질
3
Hazard Classifications
Acute Tox. 4 OralSkin Corr. 1B
스토리지 클래스
8A - Combustible corrosive hazardous materials
유해 물질 데이터
21351-79-1(Hazardous Substances Data)
응용 분야 · 2건

용도Cesium hydroxide is used in the preparation of porous cesium titanosilicates, which are potential ion-exchange materials utilized for radioactive wastes cleaning purpose. It is also involved in the preparation of other cesium salts. Further, it is used as an electrolyte in alkaline storage batteries and as a catalyst in organic synthesis. In addition to this, it is used in color photography.

일반 설명Cesium hydroxide is a colorless to yellow crystalline solid. Harmful to skin and eyes. Used in electric storage batteries.

제조 방법

Cesium hydroxide is prepared by electrolysis of cesium salts to obtain cesium metal, which then reacts with water to yield hydroxide. It also is prepared by the action of barium hydroxide with an aqueous solution of cesium sulfate.

상·하류 제품 정보

상류 원료

수산화칼륨세슘 황산염수산화 바륨

공급사72 곳

国药集团化学试剂有限公司86-21-63210123 · [email protected]
廊坊乾耀科技有限公司0316-2617888 17301291189 · [email protected]
杭州品高化工有限公司0571-87658025 · [email protected]
杭州鼎燕化工有限公司13588754826 13588754826 · [email protected]
上海欧金实业有限公司13564718081 13564718081 · [email protected]
Dayang Chem (Hangzhou) Co.,Ltd.+86-0571-88938639 17705817739 · [email protected]
上海迈瑞尔生化科技有限公司4006356688 18621169109 · [email protected]
武汉市聚舜化工有限公司027-02783261126 18971318572 · [email protected]
阿法埃莎(中国)化学有限公司400-6106006 · [email protected]
北京大田丰拓化学技术有限公司13651141086 · [email protected]
安耐吉化学&3A(安徽泽升科技股份有限公司)400-0056266 · [email protected]
广东云星生物技术有限公司0751-18902340975/189023400307 18902340307 · [email protected]
江苏艾康生物医药研发有限公司025-5885952 15955137747 · [email protected]
武汉市皇臻生物化工有限公司13795480948 · [email protected]
广东大小化工有限公司171603 18666171603 · [email protected]
玛雅试剂+86 (573) 82222445 (0)18006601000 452520369 · [email protected]
天津希恩思生化科技有限公司400 638 7771 · [email protected]
艾科试剂4008-755-333 18080918076 · [email protected]
赛默飞世尔科技(中国)有限公司800-810-5118 · [email protected]
北京伊诺凯科技有限公司400-810-7969 010-59572699 · [email protected]
北京京土恒盛化工科技有限公司00-13911456598 13911456598 · [email protected]
北京天净沙基因科技有限公司19852949191 19852949191 · [email protected]
PT CHEM GROUP LIMITED+86-85511178; +86-85511178 · [email protected]
雷丁试剂0510-85629785 18013409632 · [email protected]
天津普西唐生物医药科技有限公司010-60605840 · [email protected]
上海麦克林生化科技股份有限公司15221275939 15221275939 · [email protected]
杭州杰恒化工有限公司0571-87396432 · [email protected]
上海嵩爰化工科技有限公司010-1234567 18521000990 · [email protected]
上海有朋化工有限公司021-69005955 13701776567 · [email protected]
上海凯赛化工有限公司021-33516722 13701817869 · [email protected]
上海彤源化工有限公司021-021-69182866 13701855675 · [email protected]
上海蓝润化学有限公司021-69515658 ; 69515628 13701998368 · [email protected]
上海容立化学科技有限公司021-69992220 13701886816 · [email protected]
上海康拓化工有限公司021-69185552 13701777608 · [email protected]
Sigma-Aldrich西格玛奥德里奇(上海)贸易有限公司021-61415566 800-8193336 · [email protected]
九鼎化学(上海)科技有限公司4009209199 · [email protected]
杭州鼎燕化工有限公司0571-87157530-8003 18049756717 · [email protected]
厦门志信化学有限公司+86-5922680277 +86-13806087780 · [email protected]
广东翁江化学试剂有限公司0751-2886766 13927870850 · [email protected]
上海玻尔化学试剂有限公司19102157732 · [email protected]
sgtlifesciences pvt ltd+91-8790379245 · [email protected]
上海阿拉丁生化科技股份有限公司6206333 13167063860 · [email protected]
启源(广东)医药化工有限公司18026564465 · [email protected]
陕西缔都医药化工有限公司+86-29-81139210 +86-17392587031 · [email protected]
上海源叶生物科技有限公司18916372613 · [email protected]
上海新平精细化学品有限公司18221735425 · [email protected]
上海贤鼎生物科技有限公司021-021-52271985 17721149837 · [email protected]
Shanghai Acmec Biochemical Technology Co., Ltd.+86-18621343501 · [email protected]
上海百舜生物科技有限公司021-37581181 · [email protected]
上海易恩化学技术有限公司400-400-1332688 18019345275 · [email protected]

추가 설명

정의ChEBI: Caesium hydroxide is an alkali metal hydroxide and a caesium molecular entity.