| GHS 분류 | DangerH220: Extremely flammable gas [Danger Flammable gases]P203, P210, P222, P280, P377, P381, and P403 (click each P-code to see the statement) |
|---|
| 규제 정보 | Chemical: EthaneEthane is listed on the EPA's Chemical Data Reporting (CDR) system. Manufacturers and importers of Ethane are required to report information about their production and use of this chemical to the EPA under the Toxic Substances Control Act (TSCA). (40 eCFR Part 711)Status: Active Update: 28-11-2022 https://echa.europa.eu/registration-dossier/-/registered-dossier/14543Status: Cease Manufacture Update: 10-11-2008 https://echa.europa.eu/registration-dossier/-/registered-dossier/5099Ethane: HSNO Approval: HSR000998 Approved with controlsThe New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.) |
|---|
| 기타 안전 정보 | IMAP assessments - Ethane: Human health tier I assessment |
|---|
| 운송 라벨(DOT) | Flammable Gas |
|---|
| 화재 위험 | Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:EXTREMELY FLAMMABLE. Will be easily ignited by heat, sparks or flames. Will form explosive mixtures with air. Vapors from liquefied gas are initially heavier than air and spread along ground. CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966), Methane (UN1971) and Hydrogen and Methane mixture, compressed (UN2034) are lighter than air and will rise. Hydrogen and Deuterium fires are difficult to detect since they burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.) Vapors may travel to source of ignition and flash back. Cylinders exposed to fire may vent and release flammable gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket. CAUTION: When LNG - Liquefied natural gas (UN1972) is released on or near water, product may vaporize explosively. (ERG, 2024)· EXTREMELY FLAMMABLE.· Will be easily ignited by heat, sparks or flames.· Will form explosive mixtures with air.· Vapors from liquefied gas are initially heavier than air and spread along ground.CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966), Methane (UN1971) and Hydrogen and Methane mixture, compressed (UN2034) are lighter than air and will rise. Hydrogen and Deuterium fires are difficult to detect since they burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.)· Vapors may travel to source of ignition and flash back.· Cylinders exposed to fire may vent and release flammable gas through pressure relief devices.· Containers may explode when heated.· Ruptured cylinders may rocket.CAUTION: When LNG - Liquefied natural gas (UN1972) is released on or near water, product may vaporize explosively.Extremely flammable. Gas/air mixtures are explosive. |
|---|
| 화재 가능성 | Flammable in the presence of an oxidizing gas (eg air), a source of ignition, and when the concentration of the gas is between the lower and upper explosive limits. Keep away frmo heat/sparks/open flame/hot surface/oxidizing gas. No smoking.Severe fire risk if exposed to sparks or open flame. |
|---|
| 건강 유해성 | In high vapor concentrations, can act as simple asphyxiant. Liquid causes severe frostbite. (USCG, 1999)Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas. Some may be irritating if inhaled at high concentrations. Contact with gas, liquefied gas or cryogenic liquids may cause burns, severe injury and/or frostbite. Fire may produce irritating and/or toxic gases. (ERG, 2024)· Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas.· Some may be irritating if inhaled at high concentrations.· Contact with gas, liquefied gas or cryogenic liquids may cause burns, severe injury and/or frostbite.· Fire may produce irritating and/or toxic gases. |
|---|
| 유해성 요약 | The Critical Effects for aliphatic hydrocarbon gases are CNS depression and cardiac sensitization. From a toxicologic standpoint, methane and ethane are practically inerthowever, at very high concentrations, they act as a simple asphyxiant and can cause suffocation by displacement of oxygen from breathing atmosphere, below the critical level of 16% oxygen that is required to sustain life. [ACGIH] Simple asphyxiantCauses narcosis at high concentrations[Merck Index] Evaporating liquid can cause frostbite[ICSC] |
|---|
| 운송 번호 및 가이드(DOT) | 1961 1151035 115 |
|---|
| 반응성 그룹 | Hydrocarbons, Aliphatic Saturated |
|---|
| EC 분류 | Symbol: F+R: 12S: (2)-9-16-33 |
|---|
| UN 분류 | UN Hazard Class: 2.1 |
|---|
| Reactivity Alerts | Highly Flammable |
|---|
| 소화 | Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED. CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966) and Hydrogen and Methane mixture, compressed (UN2034) will burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.).SMALL FIRE: Dry chemical or CO2.LARGE FIRE: Water spray or fog. If it can be done safely, move undamaged containers away from the area around the fire. CAUTION: For LNG - Liquefied natural gas (UN1972) pool fires, DO NOT USE water. Use dry chemical or high-expansion foam.FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devicesicing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzlesif this is impossible, withdraw from area and let fire burn. (ERG, 2024)Shut off supplyif not possible and no risk to surroundings, let the fire burn itself out. In other cases extinguish with water spray, powder. In case of fire: keep cylinder cool by spraying with water. Combat fire from a sheltered position. |
|---|
| 응급 조치 | Fresh air, rest. Artificial respiration may be needed. Refer for medical attention.ON FROSTBITE: rinse with plenty of water, do NOT remove clothes. Refer for medical attention .First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention. |
|---|
| 누출 비상 조치 | · CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.· Keep unauthorized personnel away.· Stay upwind, uphill and/or upstream.· Many gases are heavier than air and will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.).· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.· All equipment used when handling the product must be grounded.· Do not touch or walk through spilled material.· Stop leak if you can do it without risk.· If possible, turn leaking containers so that gas escapes rather than liquid.· Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.· Do not direct water at spill or source of leak.CAUTION: For LNG - Liquefied natural gas (UN1972), DO NOT apply water, regular or alcohol-resistant foam directly on spill. Use a high-expansion foam if available to reduce vapors.· Prevent spreading of vapors through sewers, ventilation systems and confined areas.· Isolate area until gas has dispersed.CAUTION: When in contact with refrigerated/cryogenic liquids, many materials become brittle and are likely to break without warning. |
|---|
| 응급 처치 | Remove from exposuresupport respiration. (USCG, 1999)Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:Refer to the "General First Aid" section. Specific First Aid: Clothing frozen to the skin should be thawed before being removed. In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)General First Aid:· Call 911 or emergency medical service.· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.· Move victim to fresh air if it can be done safely.· Administer oxygen if breathing is difficult.· If victim is not breathing:-- DO NOT perform mouth-to-mouth resuscitationthe victim may have ingested or inhaled the substance.-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.· Remove and isolate contaminated clothing and shoes.· For minor skin contact, avoid spreading material on unaffected skin.· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.· For severe burns, immediate medical attention is required.· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.· Keep victim calm and warm.· Keep victim under observation.· For further assistance, contact your local Poison Control Center.· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.Specific First Aid:· Clothing frozen to the skin should be thawed before being removed. |
|---|
| 안전 보관 | Fireproof. Cool. Separated from strong oxidants and halogens. |
|---|
| Firefighting Hazards | Flashback along vapor trail may occur.Under fire conditions the cylinders may violently rupture and rocket.... As a result of flow, agitation, etc, electrostatic charges can be generated ... On loss of containment ... /ethane/ can cause suffocation by lowering the oxygen content of the air in confined areas ... Rapid evaporation of the liquid may cause frostbite. |
|---|
| 노출 관리 및 개인 보호 | · Wear positive pressure self-contained breathing apparatus (SCBA).· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.· Always wear thermal protective clothing when handling refrigerated/cryogenic liquids. |
|---|
| 소화 절차 | Wear self contained breathing apparatus for fire fighting if necessary.Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.Use water spray to cool unopened containers.To fight fire stop flow of gas.For more Fire Fighting Procedures (Complete) data for ETHANE (7 total), please visit the HSDB record page. |
|---|
| 보관 조건 | Keep container tightly closed in a dry and well-ventilated place.Fireproof. Cool. Separated from strong oxidants and halogens.Storage temp: -128 °Fventing: safety relief |
|---|
| 정리 방법 | Evacuate danger area! Consult an expert! Personal protection: self-contained breathing apparatus. Ventilation. Remove all ignition sources. NEVER direct water jet on liquid. |
|---|
| 비화재 누출 대응 | Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. If possible, turn leaking containers so that gas escapes rather than liquid. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Do not direct water at spill or source of leak. CAUTION: For LNG - Liquefied natural gas (UN1972), DO NOT apply water, regular or alcohol-resistant foam directly on spill. Use a high-expansion foam if available to reduce vapors. Prevent spreading of vapors through sewers, ventilation systems and confined areas. Isolate area until gas has dispersed. CAUTION: When in contact with refrigerated/cryogenic liquids, many materials become brittle and are likely to break without warning. (ERG, 2024) |
|---|
| 처리 방법 | Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting as this material is highly flammable. Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material. |
|---|
| 환경 거동 | TERRESTRIAL FATE: Based on a classification scheme(1), an estimated Koc value of 37(SRC), determined from a log Kow of 1.81(2) and a regression-derived equation(3), indicates that ethane is expected to have very high mobility in soil(SRC). Volatilization of ethane from moist soil surfaces is expected to be an important fate process(SRC) given an estimated Henry's Law constant of 0.5 atm-cu m/mole(SRC), derived from its vapor pressure, 3.15X10+4 mm Hg(4), and water solubility, 60.2 mg/L(5). Ethane is expected to volatilize from dry soil surfaces(SRC) based upon its vapor pressure(4). Ethane was oxidized to ethanol in lake water and soil within 24 hours using cell suspensions from over 20 methyltrophic organisms(6,7). This suggests that biodegradation may be an important fate process in the environmenthowever, ethane is a gas and therefore volatilization is expected to be the dominant fate process(SRC).AQUATIC FATE: Based on a classification scheme(1), an estimated Koc value of 37(SRC), determined from a log Kow of 1.81(2) and a regression-derived equation(3), indicates that ethane is not expected to adsorb to suspended solids and sediment(SRC). Volatilization from water surfaces is expected(4) based upon an estimated Henry's Law constant of 0.5 atm-cu m/mole(SRC), derived from its vapor pressure, 3.15X10+4 mm Hg(5), and water solubility, 60.2 mg/L(6). Using this Henry's Law constant and an estimation method(4), volatilization half-lives for a model river and model lake are 1.6 hours and 2.2 days, respectively(SRC). According to a classification scheme(7), an estimated BCF of 7.3(SRC), from its log Kow(2) and a regression-derived equation(3), suggests the potential for bioconcentration in aquatic organisms is low(SRC). Ethane is not expected to undergo hydrolysis in the environment due to the lack of functional groups that hydrolyze under environmental conditions(4). Ethane was oxidized to ethanol in lake water and soil within 24 hours using cell suspensions from over 20 methyltrophic organisms(8,9). This suggests that biodegradation may be an important fate process in the aquatic environmentATMOSPHERIC FATE: According to a model of gas/particle partitioning of semivolatile organic compounds in the atmosphere(1), ethane, which has a vapor pressure of 3.15X10+4 mm Hg at 25 °C(2), is expected to exist solely as a gas in the ambient atmosphere. Gas-phase ethane is degraded in the atmosphere by reaction with photochemically-produced hydroxyl radicals(SRC)the half-life for this reaction in air is estimated to be 60 days(SRC), calculated from its rate constant of 2.68X10-13 cu cm/molecule-sec at 25 °C(3). Based on data for iso-octane and n-hexane, ethane is not expected to absorb UV light at wavelengths >290 nm(4) and, therefore, is not expected to be susceptible to direct photolysis by sunlight(SRC). |
|---|
| 유해 작용 | Neurotoxin - Acute solvent syndromeOther Poison - Simple Asphyxiant |
|---|
| 노출 경로 | The substance can be absorbed into the body by inhalation. |
|---|
| Average Daily Intake | AIR INTAKE: According to the National Ambient Volatile Organic Compounds (VOCs) Database, the median urban atmospheric concn of ethane is 9.150 ppbV for 571 samples. Based upon this figure and the value for average daily inhalation by a human adult of 20 cu m of air, the average daily intake of ethane via air is 183 mg(1). |
|---|
| Signs and Symptoms | Suffocation.ON CONTACT WITH LIQUID: FROSTBITE. |
|---|
| Effluent Concentrations | Flue gases from a waste incinerator at Babylon, Long Island, NY were found to contain ethane at concentration generally less than 0.5 ppm(1). Ethane is also a product of gasoline(2-4), natural gas(4), and polyethylene(5) combustion. The average exhaust from 67 gasoline fueled vehicles was found to contain ethane at a concentration of 1.2% by weight of total hydrocarbon(3). Ethane from car exhaust ranged in concentration from 0.32 to 0.93 ppmV with an average for 8 samples of 0.53 ppmV(4). A Texaco refinery located in Tulsa, OK attributed emissions to the surrounding atmosphere where the ethane concentration was measured to be 33.8 and 73.5 ppbC for two minutes before and after 1:33PM(6). The ethane content of the air downwind of a Mobil natural gas facility in Rio Blanco, CO was 136.1 ppbC(6). Underwater hydrocarbon vent discharges from offshore oil production platforms were found to contain ethane concentration in the vapor phase at 2600 umol/L of gas(7). Gas-phase emissions from open burning of six fine (foliar) fuels, loblolly pine, western hemlock, ponderosa pine, mixed hardwood forest foliage litter, Florida palmetto/slash pine, and wiregrass/longleaf pine, contained ethane at rates of 505.6, 338.2, 500.3, 334.3, 315.0, and 259.5 mg/kg of biomass burned, respectively(8).Ethane was detected in the gas phase of a Los Angeles tunnel at 119 mg/L(1). Ethane was detected in a tunnel in Antwerp, Belgium at a concentration of 166 ug/cu m(2), which is about 5 times greater than the background ethane levels of 30 ug/cu m(2). In a study of volatile organic contaminants in tunnels, ethane was found in the Cassiar tunnel in Vancouver in 1993 and 1995, as well as Tuscorora, Caldecott and Ft Mc Henry tunnels at concentrations of 0.92, 0.025, 0.93, 0.69 and 0.72 respectively(3). Ethane was released from cars driving in urban, suburban, rural and motor ways were observed as 26.25, 14.87, 11.16 and 10.65 mg/km(4). Ethane detections in exhaust had a mean concentration of 0.21 ppm(5). Ethane was detected with annual means of 1-2 ug/cu m in London background, 4 ug/cu m curbside and annual mean ranging from 4-25 ug/cu m in European cities(5). Ethane was detected at a median concentration of 21.4 ppbC from 1984-1986 in 39 US cities(6). In a study of reformulated gasoline in California, ethane, which accounted for 0% by weight of the gasoline, was found to account for 1.5% of nonmethane organic tunnel emissions(7).Ethane accounted for 0.01, 0.01 and 0.02% of emissions from regular, mid-grade, and premium vehicle emissions, respectively, and 1.81 and 4.38% of the emissions from roadways and refineries, respectively(1). Ethane accounted for 0.86 and 0.01% of the emissions from regular summer blend gasoline in Atlanta and Chicago, respectively(1). Ethane accounted for 1.3 and 1.2% of the total VOC concentrations of low oxygenate and high oxygenate gasoline, respectively(2). In non-catalytic engines, ethane was released at concentrations of 13.27 and 12.6 mg/km for reference and reformulated fuels, respectively(3). In 3-way catalytic engines, ethane was released at concentrations 9.63 and 8.59 mg/km for reference and reformulated fuels, respectively(3). Ethane accounted for 3.1% vehicle emissions and 4.8% petroleum refineries(4). The MS Aurora and Stena Danica ferries operating in the Skagerak-Kattegatt-Oresund region of Sweden, release ethane at a concentration of <0.6 mg/cu nm dry weight(5). |
|---|
| Soil Adsorption/Mobility | The Koc of ethane is estimated as 37(SRC), using a log Kow of 1.81(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that ethane is expected to have very high mobility in soil. |
|---|
| Natural Pollution Sources | Ethane is a constituent in the paraffin fraction of crude oil and natural gas(1). |
|---|
| Atmospheric Concentrations | URBAN/SUBURBAN: The average ethane concentration for 2 samples per 4 sites in Tulsa, OK was 19.2 ppbC with a range of 2.3 to 73.5 ppbC(1). The ethane concentrations for 6 sites in Rio Blanco, CO averaged 27.0 ppbC with a range from 4.6 to 136.1(1). Ethane was detected in 20 of 20 air samples from Houston, TX ranging in concentration from 13.8 to 751.8 ppm with an average of 124.2 ppm(2). The arithmetic and geometric means were 54.2 and 44.2 ppbC, respectively, for the atmospheric ethane content at urban locations in New England(3). The ground level atmospheric concentration of ethane at 13:25 was 79 ppb and 406 ppb at 08:00 for Huntington Park, CA(4). At 1500 ft the ethane concentration was 43 ppb at 07:43 and at 08:07 at a height of 2,200 ft the ethane concentration was 39 ppb(4). The ethane concentration ranged from 32 to 221 ppbV at a downtown Los Angeles location during the Fall of 1981(5). The ethane concentration at 1100 ft just east of Antioch, CA was 11.5 ug/cu m, at 1000 ft near Pittsburg, CA was 7.0 ug/cu m, at 1100 ft over Carquinez Strait, CA was 5.5 ug/cu m and at 1000 ft over San Pablo Bay, CA was 4.0 ug/ cu m(6). Ethane was detected in Atlanta, GA in 1992 with an average concentration of 101.1 ppb(7). The ethane concentrations were 3.5, 3.0, and 2.5 ug/cu m at 10, 15, and 40 miles downwind of Janesville, WI on August 14, 1978(8). According to the National Ambient Volatile Organic Compounds (VOCs) Database, the median urban and suburban atmospheric concentrations of ethane were 9.150 ppbV for 571 samples and 15.780 ppbV for 226 samples,respectively(9).URBAN/SUBURBAN: Ethane was detected in the atmospheres of Pretoria, Johannesburg and Durban, South Africa(1). Ethane was identified in the ambient air of Sydney, Australia(2) ranging in concentration from 0.8 to 42.4 ppbV with an average concentration of 9.4 ppbV(3). Ethane was detected at an average concentration of 124.9 ppbC in the atmosphere over the British Columbia Research Council Laboratory at the University of British Columbia(4). The average ethane concentration in the air over Tokyo, Japan in 1980 and 1981 were 2.7 and 2.4 ppb for 66 and 192 samples, respectively(5). At Deuselbach, Hunsruck in Germany, the atmospheric ethane concentration was 1.55 ppb for October 23 1983(6). The minimum, maximum and average ethane concentrations in the ambient air of Bombay, India were 1.4, 355.7 and 26.7 ppb, respectively(7). Ethane was detected in urban Australia at a concentration of 7.5 ppb(8). In 1990 ethane comprised 1.68% of UK volatile emissions based on mass(9). Ethane was detected in Tapei, Taiwan, Chicago, IL and Osaka, Japan at concentrations of 8.3, 6.4 and 24.3 ppbV, respectively(10). Ethane was detected in 100% of the urban areas tested with a mean concentration of 5.37 ppb(11). Ethane was detected in rural (Fohnau), residential (Nansen Strasse) and street (Frankfurter Alee) sites in Berlin, Germany at concentrations of 2.59, 4.87 and 7.11 ug cu m, respectively(12). Ethane was detected in Edmonton, Alberta, Canada at median concentrations 10.13 and 11.66 ug/cu m in downtown and industrial areas, respectively(13). Ethane was detected in Vienna, Austria (1988), Sydney, Australia (1982), Chicago, IL (1989) and Osaka, Japan (1993) in average concentrations of 28.3, 7.5, 6.4 and 24.3 ppbV, respectively(14).INDOOR: Ethane was detected in the air at the 6th floor of the Cooper Union Building, at street level and the 82nd floor of the Empire State Building, at the World Trade Buildings and the Interstate Sanitation Commission in New York City, NY at 6:00-9:00AM, 9:00-11:00AM and 1:00-3:00PM, in July 1978(1). Ethane was detected at an average concentration of 12.3 ug/cu m for 5 samples collected at the 82nd floor of the World Trade Center in New York City between 5:00AM - 5:30PM Aug 23, 1977(2).RURAL/REMOTE: The respective median, minimum, and maximum atmospheric concentrations of ethane for 5 rural locations in North Carolina ranged from 2.6 to 9.1, 1.1 to 7.2, and 2.6 to 13.0 ppb(1). The atmospheric concentration of ethane for Jones State Forest, TX ranged from 17.7 to 38.4 ppb with an average of 27.1 ppb for 10 samples(2). The arithmetic and geometric means were 14.9 and 6.4 ppbC, respectively, for the atmospheric ethane content at rural locations in New England(3). Forest hydrocarbon emissions near Baton Rouge, Louisiana had background ethane levels of 5-35 ppbv(4). Ethane was detected at concentration of 2.3 ppbC in Everglades Florida(5). For 9 samples collected over a 30 hour period, the average ethane concentration in the Smokey Mountains, NC was 11.4 ppbC with a range from 8.6 to 16.0 ppbC(6). On Aug 27, 1976, the average ethane concentration for air over Lake Michigan at altitudes of 2000, 2500, and 3000 ft was 7.5 ppbV(7). On Aug 28, 1976, the average ethane concentration for air over Lake Michigan at altitudes of 1000 and 1500 ft was 2.3 ppbV(7). Ethane was detected at concentrations ranging from 0.86 to 2.1 ppbv, with an average concentration of 1.27 ppbv, in ambient air samples collected from a rural site at the summit of Whiteface Mountain in New York in July 1994(8). According to the National Ambient Volatile Organic Compounds (VOCs) Database, the median rural and remote atmospheric concentrations of ethane were 3.821 ppbV for 33 samples and 2.095 ppbV for 10 samples, respectively(9).For more Atmospheric Concentrations (Complete) data for ETHANE (6 total), please visit the HSDB record page. |
|---|
| Human Toxicity Excerpts | /SIGNS AND SYMPTOMS/ Ethane is considered to be physiologically and toxicologically inert. At high concn, ethane acts primarily as a simple asphyxiant by displacing oxygen from the blood and air. Oxygen deprivation and asphyxiation eventually lead to unconsciousness and death./SIGNS AND SYMPTOMS/ Skin /and/ Eyes ON CONTACT WITH /ethane/ LIQUID: FROSTBITE./SIGNS AND SYMPTOMS/ On loss of containment ... /ethane/ can cause suffocation by lowering the oxygen content of the air in confined areas ... Rapid evaporation ... may cause frostbite ... .../OTHER TOXICITY INFORMATION/ From a toxicologic standpoint, methane and ethane are of low anesthetic potency and are practically inerthowever, at very high concentrations, they act as a simple asphyxiant and can cause suffocation by displacement of oxygen from breathing atmosphere, below the critical level of 16% oxygen that is required to sustain life. |
|---|
| Artificial Pollution Sources | Ethane's production and use as a compound in the manufacture of ethylene by high-temperature thermal crackingas a feedstock in the production of vinyl chloridein the synthesis of chlorinated hydrocarbonsas a refrigerantand as a component of fuel gas (so-called bottled gas or suburban propane)(1) may result in its release to the environment through various waste streams(SRC). Emissions from the combustion of gasoline(2-4), foliar fuels(5), polyethylene(6), and waste incinerators(7) may also contribute to its direct release into the environment.Typical ethane emissions were as follows: diesel engine: 1.8% of emitted hydrocarbonsreciprocating engine: 2.0% of emitted hydrocarbonsrotary gasoline engine: 1.3% of emitted hydrocarbonsexpected ground level concentration in USA urban air: 0.05-0.50 ppmin flue gas of municipal incinerator: < 0.4-0.5 ppmin gasoline engine exhaust: 1.8% of emitted hydrocarbons(1). Flue gases from a waste incinerator were found to contain ethane at concentrations generally less than 0.5 ppm(2). Ethane was detected at <3 ug/L in dissolved gases from a former landfill(3).Anaerobic transformations of 1,1,1-trichloroethane (TCA), 1,1-dichloroethane (DCA), and chloroethane (CA) were studied with sludge from a lab-scale, municipal wastewater sludge digester. TCA was biologically transformed to DCA and CA and further to ethane by reductive dechlorination. TCA was also converted to acetic acid and 1,1-dichloroethene (11DCE) by cell-free extract. 11DCE was further biologically converted to ethene. This pathway was confirmed by transformation tests of TCA, DCA and CA, by tests with cell-free extract, and by chloride release during TCA degradation. With cell-free extract, acetic acid accounted for approximately 90% of the TCA transformedtests with live cells indicate that the fraction of TCA transformed by this pathway decreased with lower biomass. The dechlorination of DCA to CA and CA to ethane was not stoichiometric. A high rate of TCA removal was observed under the experimental conditions. The results indicate that removal of TCA in anaerobic digestion should be complete, but DCA and CA could persist in a normally operating digester. |
|---|
| Environmental Biodegradation | AEROBIC: Within 24 hr, ethane was oxidized to its corresponding alcohol, ethanol, by cell suspensions of over 20 methyltrophic organisms isolated from lake water and soil samples(1,2). The respective gas exchange and degradation rate constants were 0.83X10-5 sq cm sec-1 and 0.027 day-1 for ethane contained in a model estuarine ecosystem at 10 °C and a salinity of 30 parts per thousandthe corresponding biodegradation half-life was greater than 87 days(3). At 20 °C and a salinity of 30, the respective gas exchange and degradation rate constants were 1.132X10-5 sq cm sec-1 and 0.062 day-1the corresponding biodegradation half life for n-ethane ranged from 21 to 33 days(3). |
|---|
| DHS Chemicals of Interest (COI) | Ethane110000Flammable chemical that can be released at a facility. |
|---|
| 신호 어 | Danger |
|---|
| 유해·위험 문구 | 암호 유해·위험 문구 위험 등급 범주 신호 어 그림 문자 P- 코드 H220 |
|---|