돌아가기
Huagongshe화공사 화학 정보 인쇄 보고서 · 연구 참고용
HRID 511887생성일: 2026년 10월 23일

Isostearyl Alcohol EX → Sodium isostearylsulfate carbon dioxide

https://huagongshe.com/ko/reaction/511887

반응식

참여 물질

역할이름HCID투입량
반응물Isostearyl Alcohol EXHCID 62825—
반응물HCID 23698004HCID 23698004—
생성물Sodium isostearylsulfate carbon dioxideHCID 89388392—

반응 단계

Into a piston front part (window side) in the variable-volume high-pressure cell, 0.143 g (0.386 mmol) of sodium isostearylsulfate (containing 13.9% of isostearyl alcohol as an impurity) obtained in Example 1 was charged and the apparatus was closed tightly, followed by drying the inside of the variable-volume high-pressure cell using a vacuum pump. Next, the temperature inside of the variable-volume high-pressure cell was set at 35° C. and into the piston front part of the variable-volume high-pressure cell, 20 g (sodium isostearylsulfate concentration (relative to carbon dioxide): 0.08% by mol) of carbon dioxide (manufactured by Nippon Ekitan Corporation; purity: 99.99% or more) was pressed. Then, the temperature inside of the variable-volume high-pressure cell was elevated to 75° C. and the pressure in the piston rear part of the variable-volume high-pressure cell was set to 37 MPa, followed by stirring the mixture in the variable-volume high-pressure cell to obtain a transparent and homogeneous sodium isostearylsulfate/carbon dioxide solution. Next, to the sodium isostearylsulfate/carbon dioxide solution, 40 μL of a 0.1% by weight sodium p-toluenesulfonate aqueous solution prepared by a method including: dissolving 0.0392 g of p-toluenesulfonic acid (manufactured by Wako Pure Chemical Industries, Ltd.) in 40 mL of water and neutralizing the resultant solution with sodium hydrogen carbonate (manufactured by Wako Pure Chemical Industries, Ltd.); utilizing a six-ports valve and a high pressure pump, was added as the marker solution and the resultant mixture was stirred. At the time when a homogeneous one liquid phase was obtained, an UV-Vis absorption spectrum was measured by a spectrophotometer (manufactured by Hitachi High-Technologies Corporation; U-2810) through a pressure resistant spectrum cell (manufactured by L. TEX Corporation; light path length: 10 mm) having a quartz window that was connected to the apparatus. By repeating the addition of 40 μL of a sodium p-toluenesulfonate aqueous solution, the stirring of the reaction mixture, and the measurement of the UV-Vis absorption spectrum, the data until W0=86.5 (W0c=71.5) were collected.

출처 및 근거

DOI10.6084/m9.figshare.5104873.v1
특허 번호US09101894B2
출처 데이터셋uspto-grants-2015_08
ORD IDord-35ad1a02c7674ba6a0904991a7a22658
출처 메모uspto-grants-2015_08