反应详情
EQUATION
反应方程式
REACTANTS
反应物
PRODUCTS
生成物
CONDITIONS
反应条件
- 温度
- 75 °C
PROCEDURE
实验过程
A solution of 1,4-diacetoxy-2-butene (0.5 g) and HRh(CO)(PPh3)3-anchored in MCM-48 (0.05 g) in toluene (25 ml) was heated in an autoclave at 75° C., under 800 psig of synthesis gas (50% by volume H2 and 50% by volume CO gas). The reaction was monitored for gas absorption. After the theoretical amount of gas absorption (44 psig) took place and consequently there was no further gas uptake, the reaction was stopped and then the autoclave was cooled to room temperature. The solid catalyst was recovered by decantation of the reaction mixture. The reaction mixture was analyzed by HP 6890 gas chromatograph to give pure 2-Formyl-4-acetoxybutene (99.9% yield and 100% selectivity to 2-Formyl-4-acetoxybutene). Later toluene was removed from the reaction mixture by distillation to get the pure fraction of 2-Formyl-4-acetoxybutene (b.p. 78-79° C./5 mm Hg). The recovered catalyst was recycled five times. It was found that there was no loss in activity upon each recycle. ICP analysis also showed no leaching of the rhodium catalyst.
WORKUP
后处理
- customThe reaction was monitored for gas absorption
- customAfter the theoretical amount of gas absorption (44 psig)
- temperaturethe autoclave was cooled to room temperature
- customThe solid catalyst was recovered by decantation of the reaction mixture