Back
HuagongsheHuagongshe Chemistry Print Report · For research reference only
HRID 2068427Generated: October 31, 2026

Diisopropylethylamine → Ammonium Acetate

https://huagongshe.com/reaction/2068427

Reaction equation

Participants

RoleNameHCIDCharge
ReactantDiisopropylethylamineHCID 81531—
Reactant1-PhenylcyclopropylamineHCID 194548—
ReactantMethanaminium, N-((dimethylamino)(3H-1,2,3-triazolo(4,5-b)pyridin-3-yloxy)methylene)-N-methyl-, hexafluorophosphate(1-) (1:1)HCID 9886157—
ReactantHCID 59411416HCID 59411416—
SolventDimethylformamideHCID 6228—
ProductAmmonium AcetateHCID 517165—
ProductHCID 46842510HCID 46842510—

Reaction Steps

To a solution containing 1-phenylcyclopropanamine hydrochloride (0.0067 g, 0.040 mmol), diisopropylethylamine (0.14 mL, 0.79 mmol), 5-(4-fluoro-2-(4-fluorophenyl)-3-(methylcarbamoyl)pyrazolo[1,5-a]pyridin-5-yl)-2-methoxy-6-methylnicotinic acid (0.018 g, 0.040 mmol) and DMF (0.27 mL) was added HATU (0.030 g, 0.080 mmol) in one portion. The solution was maintained at room temperature for 1 h and concentrated. Purification of the resultant residue using preparative HPLC (Waters-Xbridge, 50×100 mm, 5 micron, C18 column; 0.1M ammonium acetate, 0-100% B (B=5% H2O/CH3CN)/A (A=95% H2O/CH3CN), 15 min. gradient) afforded 4-fluoro-2-(4-fluorophenyl)-5-(6-methoxy-2-methyl-5-(1-phenylcyclopropylcarbamoyl)pyridin-3-yl)-N-methylpyrazolo[1,5-a]pyridine-3-carboxamide as a white solid. Preparative HPLC retention time: 13.94 min. 1H NMR (400 MHz, MeOD) δ ppm 8.54 (1H, d, J=7.03 Hz), 8.16 (1H, s), 7.84-7.95 (2H, m), 7.29 (4H, d, J=4.27 Hz), 7.14-7.26 (3H, m), 6.93 (1H, t, J=6.90 Hz), 4.18 (3H, s), 2.85-2.96 (3H, m), 2.48 (3H, s), 1.37 (4H, d, J=6.27 Hz). LCMS: retention time: 1.847 min. LC data was recorded on a Shimadzu LC-10AS liquid chromatograph equipped with a Phenomenex-Luna, 10 u, C18, 3.0×50 mm column using a SPD-10AV UV-Vis detector at a detector wave length of 220 nM. The elution conditions employed a flow rate of 4 mL/min, a gradient of 100% solvent A/0% solvent B to 0% solvent A/100% solvent B, a gradient time of 2 min, a hold time of 1 min, and an analysis time of 3 min where solvent A was 5% CH3OH/95% H2O/10 mM ammonium acetate and solvent B was 5% H2O/95% CH3OH/10 mM ammonium acetate. MS data was determined using a Micromass Platform for LC in electrospray mode. m/z 568 (MH+).

Provenance & Evidence

DOI10.6084/m9.figshare.5104873.v1
Patent numberUS08293909B2
Source datasetuspto-grants-2012_10
ORD IDord-ce22a431fdda43679b4ecc2023409c71
Source noteuspto-grants-2012_10