Back
HuagongsheHuagongshe Chemistry Print Report · For research reference only
HRID 219367Generated: October 29, 2026

Diisopropylethylamine → Ammonium Acetate

https://huagongshe.com/reaction/219367

Reaction equation

Participants

RoleNameHCIDCharge
ReactantDiisopropylethylamineHCID 81531—
ReactantMethanaminium, N-((dimethylamino)(3H-1,2,3-triazolo(4,5-b)pyridin-3-yloxy)methylene)-N-methyl-, hexafluorophosphate(1-) (1:1)HCID 9886157—
Reactant5-(4-Fluoro-2-(4-fluorophenyl)-3-(methylcarbamoyl)pyrazolo[1,5-a]pyridin-5-yl)-2-methoxy-4-methylbenzoic acidHCID 67217061—
Reactant1-(3-Methyl-1,2,4-oxadiazol-5-yl)cyclopropanaminium 2,2,2-trifluoroacetateHCID 86639954—
SolventDimethylformamideHCID 6228—
ProductAmmonium AcetateHCID 517165—
Product4-fluoro-2-(4-fluorophenyl)-5-(4-methoxy-2-methyl-5-(1-(3-methyl-1,2,4-oxadiazol-5-yl)cyclopropylcarbamoyl)phenyl)-N-methylpyrazolo[1,5-a]pyridine-3-carboxamideHCID 46842509—

Reaction Steps

To a solution containing 1-(3-methyl-1,2,4-oxadiazol-5-yl)cyclopropanaminium 2,2,2-trifluoroacetate (0.024 g, 0.095 mmol), diisopropylethylamine (0.10 mL, 0.56 mmol), 5-(4-fluoro-2-(4-fluorophenyl)-3-(methylcarbamoyl)pyrazolo[1,5-a]pyridin-5-yl)-2-methoxy-4-methylbenzoic acid (0.033 g, 0.073 mmol) and DMF (0.49 mL) was added HATU (0.056 g, 0.15 mmol) in one portion. The solution was maintained at room temperature for 1 h and concentrated. The resultant residue was purified using preparative HPLC (Waters-Xbridge, 50×100 mm, 5 micron, C18 column; 0.1M ammonium acetate, 0-100% B (B=5% H2O/CH3CN)/A (A=95% H2O/CH3CN), 15 min. gradient) afforded 4-fluoro-2-(4-fluorophenyl)-5-(4-methoxy-2-methyl-5-(1-(3-methyl-1,2,4-oxadiazol-5-yl)cyclopropylcarbamoyl)phenyl)-N-methylpyrazolo[1,5-a]pyridine-3-carboxamide as a white solid. Preparative HPLC retention time: 9.0 min. 1H NMR (400 MHz, CHLOROFORM-d) δ ppm 8.57 (s, 1H), 8.34 (d, J=7.03 Hz, 1H), 8.13 (s, 1H), 7.79-7.92 (m, 2H), 7.10-7.21 (m, 2H), 6.97 (s, 1H), 6.73 (t, J=6.78 Hz, 1H), 5.89 (d, J=4.52 Hz, 1H), 4.07 (s, 3H), 2.97 (d, J=5.02 Hz, 3H), 2.34 (s, 6H), 1.77-1.88 (m, 2H), 1.50-1.63 (m, 2H). LCMS retention time: 2.533 min. LC data was recorded on a Shimadzu LC-10AS liquid chromatograph equipped with a Phenomenex-Luna, 10 micron, C18, 3.0×50 mm column using a SPD-10AV UV-Vis detector at a detector wave length of 220 nM. The elution conditions employed a flow rate of 4 mL/min, a gradient of 100% solvent A/0% solvent B to 0% solvent A/100% solvent B, a gradient time of 0.4 min, a hold time of 1 min, and an analysis time of 5 min where solvent A was 10% CH3OH/90% H2O/10 mM TFA and solvent B was 10% H2O/90% CH3OH/10 mM TFA. MS data was determined using a Micromass Platform for LC in electrospray mode. m/z 573 (MH+).

Provenance & Evidence

DOI10.6084/m9.figshare.5104873.v1
Patent numberUS08198449B2
Source datasetuspto-grants-2012_06
ORD IDord-355d2445a439468eb9433f8b5c7a8a0a
Source noteuspto-grants-2012_06