Back
HuagongsheHuagongshe Chemistry Print Report · For research reference only
HRID 2375130Generated: October 25, 2026

Acrylic Acid → 4-Cyclohexene-1,2-dicarboxylic acid, 1,2-dimethyl ester

https://huagongshe.com/reaction/2375130

Reaction equation

Participants

RoleNameHCIDCharge
ReactantAcrylic AcidHCID 6581—
ReactantStyreneHCID 7501—
ReactantSodium HydroxideHCID 14798—
ReactantAmmonium HydroxideHCID 14923—
ReactantTert-dodecanethiolHCID 32793—
ReactantPioninHCID 6444337—
ReactantTetrasodium ethylenediamine tetraacetateHCID 86664981—
SolventWaterHCID 962—
Product4-Cyclohexene-1,2-dicarboxylic acid, 1,2-dimethyl esterHCID 24124—

Reaction Steps

To a polymerization vessel of a gas monomer reaction apparatus (manufactured by Taiatsu Techno Corporation, TAS-2J type) were charged 287 g of distilled water, 7.73 g of a surfactant (Pionin A-43-S (manufactured by TAKEMOTO OIL & FAT CO., LTD.): solid matter content of 48.5% by weight), 14.06 mL of 1 mol/L sodium hydroxide, 0.15 g of ethylenediamine tetraacetate tetrasodium salt, 255 g of styrene, 11.25 g of acrylic acid, and 3.0 g of tert-dodecyl mercaptan, followed by sealing of the reaction vessel and stirring at a stirring rate of 200 rpm. Degassing was conducted with a vacuum pump, followed by repeating nitrogen gas replacement several times. Thereto was injected 108.75 g of 1,3-butadiene, and the inner temperature is elevated to 60° C. Thereto was added a solution of 1.875 g of ammonium persulfate dissolved in 50 mL of water, and the mixture was stirred for 5 hours as it stands. The temperature was further elevated to 90° C., followed by stirring for 3 hours. After completing the reaction, the inner temperature was lowered to reach to the room temperature, and thereafter the mixture was treated by adding 1 mol/L sodium hydroxide and ammonium hydroxide to give the molar ratio of Na+ ion: NH4+ ion=1:5.3, and thus, the pH of the mixture was adjusted to 8.05. Thereafter, filtration with a polypropylene filter having the pore size of 1.0 μm was conducted to remove foreign substances such as dust followed by storage. Accordingly, Compound No. RP-1 was obtained in an amount of 774.7 g. Upon the measurement of halogen ion by ion chromatography, concentration of chloride ion was revealed to be 3 ppm. As a result of the measurement of the concentration of the chelating agent by high performance liquid chromatography, it was revealed to be 145 ppm.

Provenance & Evidence

DOI10.6084/m9.figshare.5104873.v1
Patent numberUS07465533B2
Source datasetuspto-grants-2008_12
ORD IDord-f50df48a25aa41af8c15efa7bdd5c266
Source noteuspto-grants-2008_12