Reaction equation

Participants

RoleNameHCIDCharge
ReactantEthyleneHCID 6325—
Reactant1-OcteneHCID 8125—
ReactantPropyleneHCID 8252—
ReactantBorateHCID 26574—
ReactantHCID 86584121HCID 86584121—
ReactantHCID 178418361HCID 178418361—
ProductHCID 86587919HCID 86587919—

Reaction Conditions

Temperature55 °C

Reaction Steps

The general procedure for the 1 gallon continuous solution polymerization outlined in Example 6 is employed, except that propylene and a small amount of ethylene are used instead of ethylene in order to prepare an isotactic propylene/1-octene/ethylene interpolymer. For this example, the reactor temperature is 55 degrees C., propylene is fed into the reactor at 19.97 pounds/hour, ethylene is metered into the reactor at 0.14 pounds per hour, octene is fed at 4.99 pounds/hour, and ISOPAR E solvent is fed at 24.27 pounds per hour. A catalyst solution containing 0.70 ppm Zr from Catalyst E and 0.80 ppm of Zr from Catalyst F was prepared and added to a 4 L catalyst storage tank. This solution was combined in a continuous stream with a continuous stream of a solution containing Armeenium borate in ISOPAR E and a continuous stream of a solution of MMAO-3A in ISOPAR E to give a ratio of total Zr:B:Al of 1:1.2:6. The activated catalyst solution is fed continuously into the reactor at a rate sufficient to maintain the reactor temperature at approximately 55 degrees C. Hydrogen is added as needed to control the molecular weight of the product. The polymer solution is continuously removed from the reactor exit and is contacted with a solution containing 100 ppm of water for each part of the polymer solution, and polymer stabilizers. The resulting exit stream is mixed, heated in a heat exchanger, and the mixture is introduced into a separator where the molten polymer is separated from the solvent and unreacted monomers. The resulting molten polymer is extruded and chopped into pellets after being cooled in a water bath. Product samples are collected over 1 hour time periods, after which time the melt index and density are determined for each sample. A propylene/1-octene/ethylene interpolymer is collected with a melting point of about 75 degrees C., and a melt index of about 2.

Provenance & Evidence

DOI10.6084/m9.figshare.5104873.v1
Patent numberUS07148305B2
Source datasetuspto-grants-2006_12
ORD IDord-970d2561663c401f828c147197f5da22
Source noteuspto-grants-2006_12