Grundinformationen
- CAS
353-36-6- Standard-SMILES
CCF- InChIKey
UHCBBWUQDAVSMS-UHFFFAOYSA-N- Summenformel
- C2H5F
- Durchschnittliche Molmasse
- 48,06 g/mol
- Monoisotopische Masse
- 48,03752832
Namen und Bezeichner
- Bevorzugter Name
- Fluoroethane
- IUPAC
- fluoroethane
- Lokaler Name
- Fluorethan
- Englischer Name
- FLUOROETHANE
- Summenformel
- C2H5F
- Molmasse
- 48.06
Namen und Synonyme
Weitere Namen anzeigen
Datenbank-Bezeichner
- CAS
353-36-6- PubChem CID
- 9620
- DTXSID
DTXSID2059857- UNII
- XO7SPI984C
- EC Number
- 206-531-6
- Nikkaji
- J2.578J
Eigenschaften
Berechnete Struktureigenschaften
- XLogP
- 0,9
- Polarare Oberfläche (TPSA)
- 0 Ų
- H-Brücken-Donoren
- 0
- H-Brücken-Akzeptoren
- 1
- Frei drehbare Bindungen
- 0
- Schwere Atome
- 3
- Formalladung
- 0
- Komplexität
- 2
Experimentelle und physikochemische Eigenschaften
Physical Description
Ethyl fluoride appears as a colorless, odorless, flammable gas. Can cause asphyxiation by the displacement of air. Exposure of the container to prolonged heat or fire may cause it to rupture violently and rocket.
Colorless odorless gas; [CAMEO]
Physikochemische Eigenschaften
- Schmelzpunkt
- -143 · -143,2°C
- Siedepunkt
- -37 · -37,1°C
- Dichte
- 0 · 0,818 g/cm3
- Brechungsindex
- 1.3057 · 1.3057 (589.3 nm -40℃)
- Spezifische Wärmekapazität
- 1.22 J/ · Cp(gas): 1.22 J/(g·K), at 25℃
- Henry's Law Constant
- 4.6 · 4.6×10-4 mol/(m3Pa) at 25℃, Yaws (2003)
- Oberflächenspannung
- 19.14 mN/m · 19.140 mN/m at 233.162K
- CAS Datenbank
- 353 · 353-36-6(CAS DataBase Reference)
- EPA chemische Informationen
- -161 · HFC-161 (353-36-6)
Sicherheit und Regulatorisches
GHS-Klassifizierung
GHS Classification
Danger
H220 (100%): Extremely flammable gas [Danger Flammable gases];H280 (100%): Contains gas under pressure; may explode if heated [Warning Gases under pressure]
P203, P210, P222, P280, P377, P381, P403, and P410+P403 (click each P-code to see the statement)
Aggregated GHS information provided per 72 reports by companies from 2 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.;Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.
Gefahrenhinweise
Fire Hazards
Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;EXTREMELY FLAMMABLE. Will be easily ignited by heat, sparks or flames. Will form explosive mixtures with air. Vapors from liquefied gas are initially heavier than air and spread along ground. CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966), Methane (UN1971) and Hydrogen and Methane mixture, compressed (UN2034) are lighter than air and will rise. Hydrogen and Deuterium fires are difficult to detect since they burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.) Vapors may travel to source of ignition and flash back. Cylinders exposed to fire may vent and release flammable gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket. CAUTION: When LNG - Liquefied natural gas (UN1972) is released on or near water, product may vaporize explosively. (ERG, 2024)
· EXTREMELY FLAMMABLE.;· Will be easily ignited by heat, sparks or flames.;· Will form explosive mixtures with air.;· Vapors from liquefied gas are initially heavier than air and spread along ground.;CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966), Methane (UN1971) and Hydrogen and Methane mixture, compressed (UN2034) are lighter than air and will rise. Hydrogen and Deuterium fires are difficult to detect since they burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.);· Vapors may travel to source of ignition and flash back.;· Cylinders exposed to fire may vent and release flammable gas through pressure relief devices.;· Containers may explode when heated.;· Ruptured cylinders may rocket.;CAUTION: When LNG - Liquefied natural gas (UN1972) is released on or near water, product may vaporize explosively.
· EXTREMELY FLAMMABLE.;· Will be easily ignited by heat, sparks or flames.;· Will form explosive mixtures with air.;· Vapors from liquefied gas are initially heavier than air and spread along ground.;CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966), Methane (UN1971) and Hydrogen and Methane mixture, compressed (UN2034) are lighter than air and will rise. Hydrogen and Deuterium fires are difficult to detect since they burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.);· Vapors may travel to source of ignition and flash back.;· Cylinders exposed to fire may vent and release flammable gas through pressure relief devices.;· Containers may explode when heated.;· Ruptured cylinders may rocket.;CAUTION: When LNG - Liquefied natural gas (UN1972) is released on or near water, product may vaporize explosively.
Health Hazards
Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas. Some may be irritating if inhaled at high concentrations. Contact with gas, liquefied gas or cryogenic liquids may cause burns, severe injury and/or frostbite. Fire may produce irritating and/or toxic gases. (ERG, 2024)
· Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas.;· Some may be irritating if inhaled at high concentrations.;· Contact with gas, liquefied gas or cryogenic liquids may cause burns, severe injury and/or frostbite.;· Fire may produce irritating and/or toxic gases.
· Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas.;· Some may be irritating if inhaled at high concentrations.;· Contact with gas, liquefied gas or cryogenic liquids may cause burns, severe injury and/or frostbite.;· Fire may produce irritating and/or toxic gases.
DOT ID and Guide
2453 115
2453 115
DOT Hazard Classification
Ethyl fluoride or Refrigerant gas R161
UN2453
Div 2.1 Flammable gas (49 eCFR § 173.115)
Hazard Classes and Categories
Flam. Gas 1 (100%);Press. Gas (Liq.) (100%)
Flammable agents - 4th degree
Sicherheit und Schutzausrüstung
Fire Fighting
Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED. CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966) and Hydrogen and Methane mixture, compressed (UN2034) will burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.).;SMALL FIRE: Dry chemical or CO2.;LARGE FIRE: Water spray or fog. If it can be done safely, move undamaged containers away from the area around the fire. CAUTION: For LNG - Liquefied natural gas (UN1972) pool fires, DO NOT USE water. Use dry chemical or high-expansion foam.;FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)
Accidental Release Measures
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.;· Keep unauthorized personnel away.;· Stay upwind, uphill and/or upstream.;· Many gases are heavier than air and will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.).
· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.;· All equipment used when handling the product must be grounded.;· Do not touch or walk through spilled material.;· Stop leak if you can do it without risk.;· If possible, turn leaking containers so that gas escapes rather than liquid.;· Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.;· Do not direct water at spill or source of leak.;CAUTION: For LNG - Liquefied natural gas (UN1972), DO NOT apply water, regular or alcohol-resistant foam directly on spill. Use a high-expansion foam if available to reduce vapors.;· Prevent spreading of vapors through sewers, ventilation systems and confined areas.;· Isolate area until gas has dispersed.;CAUTION: When in contact with refrigerated/cryogenic liquids, many materials become brittle and are likely to break without warning.
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.;· Keep unauthorized personnel away.;· Stay upwind, uphill and/or upstream.;· Many gases are heavier than air and will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.).
· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.;· All equipment used when handling the product must be grounded.;· Do not touch or walk through spilled material.;· Stop leak if you can do it without risk.;· If possible, turn leaking containers so that gas escapes rather than liquid.;· Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.;· Do not direct water at spill or source of leak.;CAUTION: For LNG - Liquefied natural gas (UN1972), DO NOT apply water, regular or alcohol-resistant foam directly on spill. Use a high-expansion foam if available to reduce vapors.;· Prevent spreading of vapors through sewers, ventilation systems and confined areas.;· Isolate area until gas has dispersed.;CAUTION: When in contact with refrigerated/cryogenic liquids, many materials become brittle and are likely to break without warning.
First Aid
Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;Refer to the "General First Aid" section. Specific First Aid: Clothing frozen to the skin should be thawed before being removed. In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)
General First Aid:;· Call 911 or emergency medical service.;· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.;· Move victim to fresh air if it can be done safely.;· Administer oxygen if breathing is difficult.;· If victim is not breathing:;-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.;-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).;-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.;· Remove and isolate contaminated clothing and shoes.;· For minor skin contact, avoid spreading material on unaffected skin.;· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.;· For severe burns, immediate medical attention is required.;· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.;· Keep victim calm and warm.;· Keep victim under observation.;· For further assistance, contact your local Poison Control Center.;· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.;Specific First Aid:;· Clothing frozen to the skin should be thawed before being removed.
General First Aid:;· Call 911 or emergency medical service.;· Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and avoid contamination.;· Move victim to fresh air if it can be done safely.;· Administer oxygen if breathing is difficult.;· If victim is not breathing:;-- DO NOT perform mouth-to-mouth resuscitation; the victim may have ingested or inhaled the substance.;-- If equipped and pulse detected, wash face and mouth, then give artificial respiration using a proper respiratory medical device (bag-valve mask, pocket mask equipped with a one-way valve or other device).;-- If no pulse detected or no respiratory medical device available, provide continuous compressions. Conduct a pulse check every two minutes or monitor for any signs of spontaneous respirations.;· Remove and isolate contaminated clothing and shoes.;· For minor skin contact, avoid spreading material on unaffected skin.;· In case of contact with substance, remove immediately by flushing skin or eyes with running water for at least 20 minutes.;· For severe burns, immediate medical attention is required.;· Effects of exposure (inhalation, ingestion, or skin contact) to substance may be delayed.;· Keep victim calm and warm.;· Keep victim under observation.;· For further assistance, contact your local Poison Control Center.;· Note: Basic Life Support (BLS) and Advanced Life Support (ALS) should be done by trained professionals.;Specific First Aid:;· Clothing frozen to the skin should be thawed before being removed.
Exposure Control and Personal Protection
· Wear positive pressure self-contained breathing apparatus (SCBA).;· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.;· Always wear thermal protective clothing when handling refrigerated/cryogenic liquids.
· Wear positive pressure self-contained breathing apparatus (SCBA).;· Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.;· Always wear thermal protective clothing when handling refrigerated/cryogenic liquids.
Nonfire Spill Response
Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. If possible, turn leaking containers so that gas escapes rather than liquid. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Do not direct water at spill or source of leak. CAUTION: For LNG - Liquefied natural gas (UN1972), DO NOT apply water, regular or alcohol-resistant foam directly on spill. Use a high-expansion foam if available to reduce vapors. Prevent spreading of vapors through sewers, ventilation systems and confined areas. Isolate area until gas has dispersed. CAUTION: When in contact with refrigerated/cryogenic liquids, many materials become brittle and are likely to break without warning. (ERG, 2024)
Isolation and Evacuation
Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.;LARGE SPILL: Consider initial downwind evacuation for at least 800 meters (1/2 mile).;FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions. In fires involving Liquefied Petroleum Gases (LPG) (UN1075), Butane (UN1011), Butylene (UN1012), Isobutylene (UN1055), Propylene (UN1077), Isobutane (UN1969), and Propane (UN1978), also refer to the "BLEVE - Safety Precautions" section. (ERG, 2024)
Immediate precautionary measure;· Isolate spill or leak area for at least 100 meters (330 feet) in all directions.;Large Spill;· Consider initial downwind evacuation for at least 800 meters (1/2 mile).;Fire;· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions.;· In fires involving Liquefied Petroleum Gases (LPG) (UN1075), Butane (UN1011), Butylene (UN1012), Isobutylene (UN1055), Propylene (UN1077), Isobutane (UN1969), and Propane (UN1978), also refer to the "BLEVE - Safety Precautions" section.
Immediate precautionary measure;· Isolate spill or leak area for at least 100 meters (330 feet) in all directions.;Large Spill;· Consider initial downwind evacuation for at least 800 meters (1/2 mile).;Fire;· If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions.;· In fires involving Liquefied Petroleum Gases (LPG) (UN1075), Butane (UN1011), Butylene (UN1012), Isobutylene (UN1055), Propylene (UN1077), Isobutane (UN1969), and Propane (UN1978), also refer to the "BLEVE - Safety Precautions" section.
Personal Protective Equipment (PPE)
Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. Always wear thermal protective clothing when handling refrigerated/cryogenic liquids. (ERG, 2024)
Emergency Response Planning Guidelines
· DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED.;CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966) and Hydrogen and Methane mixture, compressed (UN2034) will burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.);Small Fire;· Dry chemical or CO2.;Large Fire;· Water spray or fog.;· If it can be done safely, move undamaged containers away from the area around the fire.;CAUTION: For LNG - Liquefied natural gas (UN1972) pool fires, DO NOT USE water. Use dry chemical or high-expansion foam.;Fire Involving Tanks;· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.;· Cool containers with flooding quantities of water until well after fire is out.;· Do not direct water at source of leak or safety devices; icing may occur.;· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.;· ALWAYS stay away from tanks in direct contact with flames.;· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.
· DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED.;CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966) and Hydrogen and Methane mixture, compressed (UN2034) will burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.);Small Fire;· Dry chemical or CO2.;Large Fire;· Water spray or fog.;· If it can be done safely, move undamaged containers away from the area around the fire.;CAUTION: For LNG - Liquefied natural gas (UN1972) pool fires, DO NOT USE water. Use dry chemical or high-expansion foam.;Fire Involving Tanks;· Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.;· Cool containers with flooding quantities of water until well after fire is out.;· Do not direct water at source of leak or safety devices; icing may occur.;· Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.;· ALWAYS stay away from tanks in direct contact with flames.;· For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn.
Toxikologische Informationen
Regulatorische Informationen
Sicherheitsdaten
- tsca
- TSCA listed
- ridadr
- UN 2453 (ETHYL FLUORIDE (REFRIGERANT GAS R 161))
- hs_code
- 2903499090
- risk_code
- 10-23/24/25
- Toxizität
- LCLo inhalation in rat: 26pph/4H
- hazard_code
- F
- hazard_note
- Flammable
- safety_code
- 23-36/37/39
- hazard_class
- 2.1
Chemie und Industrie
Verwendung und Herstellung
Vor- und nachgelagerte Produkte
Vorgelagerte Rohstoffe
Nachgelagerte Produkte
Zugehörige Reaktionen
Notizen zur Verbindung
Wird geladen…