3-Benzyloxy-phenylboronic acid → 1,3,5-Trimethoxybenzene

HRID 498894

Reaktionsgleichung

Reaktionsgleichung von HRID 498894
COC(=O)/C(C)=C(/OS(=O)(=O)c1ccc(C)cc1)C1CC1.OB(O)c1cccc(OCc2ccccc2)c1>CC#N.O.O=P([O-])([O-])[O-].[Cl][Pd]([Cl])<-[P](C1=CC=C[CH]1[Fe][CH]1C=CC=C1P(c1ccccc1)c1ccccc1)(c1ccccc1)c1ccccc1.[K+].[K+].[K+]>COC(=O)/C(C)=C(/c1cccc(OCc2ccccc2)c1)C1CC1.COC(=O)/C(C)=C(\c1cccc(OCc2ccccc2)c1)C1CC1

Komponenten

12

Reaktionsbedingungen

Temperatur
25 °C

Versuchsvorschrift

To a 4 ml reaction vial equipped with a magnetic tumble stir disc under N2 atmosphere was charged (E)-methyl 3-cyclopropyl-2-methyl-3- (tosyloxy)acrylate 3-(E) (40.0 mg, 0.129 mmol), (3-(benzyloxy)phenyl)boronic acid 4 (32.3 mg, 0.142 mmol), palladium precatalyst 5 (5.96 mg, 6.44 µmol) and 1,3,5-trimethoxybenzene (2.17 mg, 0.013 mmol). ACN (1000 µl) and water (10 µl) were added and the mixture agitated to dissolve all solids. To a 40 ml vial was charged K3PO4 (2.12 g, 10.0 mmol) and water to dilute to 10 ml. The resulting 1 M aqueous K3PO4 solution was then sparged with N2 gas for 30 min in preparation for automated dispensing (387 µl, 0.387 mmol). Finally, to a 96-well sample dilution plate was charged 400 µl of a 9:1 mixture of acetonitrile and aqueous pH 3.5 ammonium formate buffer.

Aufarbeitung

  1. aliquotReaction aliquots were sampled into 96-well dilution plates (Analytical Sales 17P687) capped with pre-slit silicone/PTFE cap mats (Analytical Sales 965075).
  2. additionKeine Vorschrift aufgezeichnet

Quellen und Nachweise

ORD-Eintrag
ord-c2765f052e4d456ca9fb07cfb28c3328
Quelldatensatz
Development of an automated kinetic profiling system with online HPLC for reaction optimization
Originallink
Quelle ansehen