ホームMCPワークベンチSkills
ホームワークベンチ通知マイページ
llms.txt · MCPガイドプライバシーポリシー · 利用規約 · サポートv1.8.0
  1. ホーム
  2. /化合物

二過塩素酸マグネシウム

Magnesium perchlorate

HCID 24840
ノートを作成反応を作成見積依頼を出す
印刷プレビュー
基本情報概要名称と識別子物性安全と法規制化学と産業関連反応化合物ノート
部分構造検索類似構造を探す

基本情報

CAS
10034-81-8
標準SMILES
[Mg+2].[O-][Cl+3]([O-])([O-])[O-].[O-][Cl+3]([O-])([O-])[O-]
InChIKey
MPCRDALPQLDDFX-UHFFFAOYSA-L
分子式
Mg(ClO4)2
平均分子量
223.2 g/mol
単同位体質量
221.88206402

概要

Magnesium perchlorate appears as a white crystalline solid. Strongly absorbs water from air and dissolves in it. Accordingly, used as a regenerable drying agent. May explode under prolonged exposure to heat or fire.

名称と識別子

優先名称
Magnesium perchlorate
IUPAC
magnesium diperchlorate
現地名
二過塩素酸マグネシウム
英語名
Magnesium perchlorate
分子式
2ClO4.Mg
分子量
223.2

名称と別名

MAGNESIUM PERCHLORATE10034-81-8AnhydroneDehydritePerchloric acid, magnesium saltAnhydrous magnesium perchloratePerchlorate de magnesium7N77Z541YFDTXSID70890617magnesium(2+) ion diperchlorateRefChem:800558DTXCID401029865
名称をさらに表示
アンヒドロン二過塩素酸マグネシウムデヒドリット過塩素酸マグネシウムビス過塩素酸マグネシウム素酸マグネシウム過塩素酸マグネシウム ACS REAGENT過塩素酸マグネシウム PURISS. P.A.,DRYING AGENT,ACS REAGENT,≥98.0% (CALC. BASED ON DRY SUBSTANCE,KT)過塩素酸マグネシウム PURISS.,FREE-FLOWING POWDER,≥99.0% (CALC. BASED ON DRY SUBSTANCE,KT)過塩素酸マグネシウム,青色過塩素酸マグネシウム 1.18~3.35MM(6~14MESH)過塩素酸マグネシウム 300~850ΜM(20~48MESH)過塩素酸マグネシウム 710ΜM~2.36MM(8~24MESH)過塩素酸マグネシウム, ACS過塩素酸マグネシウム, reagent (99.9%-Mg)anhydrous magnesiumXKM 300KhKM 300ANHYDRONE(R)nesium perchLMagnesium perchLMAGNESIUM PERCHORATE

物性

構造計算による物性

極性表面積
149 Ų
水素結合供与体数
0
水素結合受容体数
8
回転可能結合数
0
重原子数
11
形式電荷
0
複雑度
95.8

実験および物理化学的性質

Chemical ClassesOther Classes -> Perchlorates
OdorOdorless
Density · 4 件

2.21 at 68 °F (USCG, 1999) - Denser than water; will sink

2.2

Density = 1.98; decomposes at 185-190 °C /Hexahydrate/

2.2 @25 °C

Color/FormWhite, granular, or flaky powder
Solubility99.3 G/100 CC OF H20 & 23.96 G/100 CC OF ALCOHOL, EACH AT 25 °C
Boiling PointDecomposes above 482.0 °F (USCG, 1999)
Decomposition · 2 件

When heated to decomposition it emits toxic fumes of /magnesium oxide and hydrogen chloride/.

/Decomposes/ above 250 °C.

Melting PointDecomposes at 250 °C
Physical Description · 2 件

Magnesium perchlorate appears as a white crystalline solid. Strongly absorbs water from air and dissolves in it. Accordingly, used as a regenerable drying agent. May explode under prolonged exposure to heat or fire.

White deliquescent solid; [CAMEO] Odorless; [HSDB] White odorless granules; [Alfa Aesar MSDS]

安全と法規制

安全情報は参考情報です。供給元の安全データシート(SDS)、適用法令、専門家による評価に代わるものではありません。

GHS分類

GHS Classification · 6 件

Danger

H271 (16.4%): May cause fire or explosion; strong Oxidizer [Danger Oxidizing liquids; Oxidizing solids]

P210, P220, P261, P264, P264+P265, P270, P271, P280, P283, P301+P317, P302+P352, P304+P340, P305+P351+P338, P306+P360, P319, P321, P330, P332+P317, P337+P317, P362+P364, P370+P378, P371+P380+P375, P403+P233, P405, P420, and P501 (click each P-code to see the statement)

Aggregated GHS information provided per 61 reports by companies from 10 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.

Danger

H272: May intensify fire; oxidizer [Danger Oxidizing liquids; Oxidizing solids]

危険有害性情報

Regulatory Information · 3 件

Chemical: Perchloric acid, magnesium salt

Status: Active Update: 11-08-2020 https://echa.europa.eu/registration-dossier/-/registered-dossier/29608

Perchloric acid, magnesium salt: HSNO Approval: HSR001331 Approved with controls

Other Safety InformationIMAP assessments - Perchlorates: Human health tier II assessment
DOT LabelOxidizer
Fire Hazards · 2 件

Behavior in Fire: Can form explosive mixture with combustible material or finely powdered metals. Increases the intensity of fires. (USCG, 1999)

CAUTION: Ammonium nitrate products may explode if involved in fire or contaminated with hydrocarbons (fuels), organic matter, other contaminants or when hot molten and contained. Treat as an explosive (GUIDE 112).

Fire Potential · 2 件

POWERFUL OXIDIZING MATERIAL; MIXTURES WITH COMBUSTIBLE ORG OR OTHER EASILY OXIDIZABLE MATERIALS...ARE IGNITED READILY BY FRICTION OR HEAT.

It is noncombustible but it will accelerate the burning of combustible materials.

化学と産業

薬理情報

Metabolism/MetabolitesThere is no evidence that magnesium perchlorate is metabolized in the body. It is rapidly eliminated from the body through the urinary tract (L894).

用途と製造

Uses · 4 件

Used as a drying agent for gases and an oxidizing agent; [HSDB]

AS REGENERABLE DRYING AGENT FOR GASES

Oxidizing agent /Magnesium perchlorate hexahydrate/

Breathing in contaminated air; drinking contaminated water; eating contaminated food; dermal and eye exposure (L894).

ImpuritiesGrade or purity: Pure anhydrous; 65-68% solution of hexahydrate in water.
Methods of ManufacturingREACTION OF MAGNESIUM HYDROXIDE & PERCHLORIC ACID.
General Manufacturing InformationPerchloric acid, magnesium salt (2:1): ACTIVE
応用分野 · 5 件

用途ガスの乾燥剤、市販品は二水塩に相当する水分を含有しているが、三水塩でもガスの乾燥に有効といわれている :(MERCK (14TH, 2006))

用途分析ガス 乾燥剤

説明Magnesium perchlorate is a powerful oxidizing agent, with the formula Mg(ClO4)2. Magnesium perchlorate decomposes at 250°C. The heat of formation is 568.90 kJ/mol. If water is added to magnesium perchlorate, the reaction is highly exothermic and may cause damage to the eyes. Thus, this salt should be added to a sufficient amount of water in order to form a dilute solution.Mg(ClO4)2·6H2O is composed of white, deliquescent crystals which are soluble in water and alcohol but explosive when in contact with reducing materials. This compound is used as a drying agent for gases. This salt is highly exothermic when added to water and releases steamy HCl gas. It can be dried to form the anhydrate by heating to 250°C under vacuum. The hexahydrate losses two molecules of water at 244°C in air and further decomposes to the dihydrate at 336°C and the anhydrate at 438°C. The anhydrate has been used as a desiccant to dry gas streams or air samples. However, it is no longer used since perchlorates tend to form explosive compounds with a variety of organic materials as well as other substances.

関連反応

35 件
反応記録を作成
HRID 222730 の反応式
HRID 222730反応物としてuspto-grants-2012_06
HRID 237328 の反応式
HRID 237328反応物としてuspto-grants-2014_02
HRID 247835 の反応式
HRID 247835反応物としてuspto-grants-1993_05
HRID 275422 の反応式
HRID 275422反応物としてuspto-grants-1995_02
HRID 370317 の反応式
HRID 370317反応物としてuspto-grants-2000_10
HRID 384869 の反応式
HRID 384869反応物としてuspto-grants-2013_02
HRID 389103 の反応式
HRID 389103反応物としてuspto-grants-2013_02
HRID 401597 の反応式
HRID 401597反応物としてuspto-grants-2014_06
1 / 5 ページ

化合物ノート

読み込み中…

このページの内容基本情報概要名称と識別子物性安全と法規制化学と産業関連反応化合物ノート
その他の操作
ノートを作成反応を作成見積依頼を出す
233-108-3magnesium;diperchlorateMFCD00011102Perchloric acid, magnesium salt (2:1)Magnesium perchlorate, dessicantmagnesium diperchlorateHSDB 661Magnesium Perchlorate, Anhydrous

データベース識別子

CAS
10034-81-8
PubChem CID
24840
DTXSID
DTXSID70890617
ChEBI
CHEBI:184579
UNII
7N77Z541YF
EC Number
233-108-3
Nikkaji
J43.886C
Other Experimental Properties · 3 件

Crystallizes from water with 6H2O; very hygroscopic; decomposes above 250 °C; dissolves in water with evolution of considerable amount of heat

Oxidizing agent

Heat of solution: -260 Btu/lb= -140 cal/g= -6.0X10+5 J/kg

物理化学的性質

融点
251 °C · 251 °C
比重(密度)
2 · 2,21 g/cm3
蒸気圧
0 Pa · 0Pa at 25℃
貯蔵温度
Hygroscopic, Room Temperature, Under inert atmosphere
溶解性
エタノール(微量)、水(微量)
外見
個体
比重
2.21 · 2.21
色
白い
水溶解度
過塩素酸マグネシウムは水、エタノールに溶けます。
Merck
14 · 14,5678
安定性
安定していますが、湿気に弱いです。酸化剤、可燃物との接触は火災の原因となります。還元剤、有機物、リン酸トリメチル、金属粉、強酸、リンとは相容れない。
InChI
1S/2ClHO4.Mg/c2*2-1(3,4)5;/h2*(H,2,3,4,5);/q;;+2/p-2
InChIKey
MPCRDALPQLDDFX-UHFFFAOYSA-L
SMILES
[Mg++].[O-]Cl(=O)(=O)=O.[O-]Cl(=O)(=O)=O
LogP
-6.53 at · -6.53 at 25℃
CAS データベース
10034 · 10034-81-8(CAS DataBase Reference)
EPAの化学物質情報
Perchloric acid, magnesium salt (2:1) (10034-81-8)
Health Hazards · 2 件

Inhalation of dust irritates mucous membranes. Ingestion of large amounts may be fatal; immediate symptoms include adominal pains, nausea and vomiting, diarrhea, pallor, blueness, shortness of breath, unconsciousness. Contact with eyes or skin causes irritation. (USCG, 1999)

· Inhalation, ingestion or contact (skin, eyes) with vapors or substance may cause severe injury, burns or death.

Hazards Summary · 1 件

Skin and mucous membrane irritant; [HSDB] Information is limited, but concentrated solutions are probably not irritating; May induce methemoglobinemia after ingestion; [CHEMINFO] Very toxic by ingestion; [CAMEO] A skin, eye, and mucous membrane irritant; [CHRIS] An oxidizing agent that may cause fire on contact with combustible materials; A skin and strong eye irritant; [Alfa Aesar MSDS] See PERCHLORATES.

DOT ID and Guide1475 140
Reactive GroupOxidizing Agents, Strong
Reactivity AlertsExplosive
Reactivity Profile · 1 件

MAGNESIUM PERCHLORATE is a strong oxidizing agent. Decomposes at 185-190 °C [Hawley]. Noncombustible but accelerates the burning of combustible materials. If large quantities are involved in the fire or the combustible material is finely divided an explosion may result. Avoid contact with mineral acids because of the danger of explosion. In the preparation of anhydrous dimethyl sulfoxide by vacuum distillation from anhydrous magnesium perchlorate, an explosion occurred [MCA Case History 1187, 1966]. Drying ethylene oxide with magnesium perchlorate resulted in an explosion [NSC Newsletter. Chem. Soc. 1959]. Magnesium perchlorate used in drying hydrocarbons exploded when heated to 220 °C [Ind. & Eng. News 17:70. 1939]. As soon as trimethyl phosphite contacted a small amount of magnesium perchlorate in a flask, there was a flash and an explosion that shattered the flask [Allison 1968].

DOT Emergency Guidelines · 5 件

/GUIDE 140: OXIDIZERS/ Fire or Explosion: These substances will accelerate burning when involved in a fire. Some may decompose explosively when heated or involved in a fire. May explode from heat or contamination. Some will react explosively with hydrocarbons (fuels). May ignite combustibles (wood, paper, oil, clothing, etc.). Containers may explode when heated. Runoff may create fire or explosion hazard.

/GUIDE 140: OXIDIZERS/ Health: Inhalation, ingestion or contact (skin, eyes) with vapors or substance may cause severe injury, burns or death. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may cause pollution.

/GUIDE 140: OXIDIZERS/ Public Safety: CALL Emergency Response Telephone Number on Shipping Paper first. If Shipping Paper not available or no answer, refer to appropriate telephone number listed on the inside back cover. As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids. Keep unauthorized personnel away. Stay upwind. Keep out of low areas. Ventilate closed spaces before entering.

/GUIDE 140: OXIDIZERS/ Protective Clothing: Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection. Structural firefighters' protective clothing will only provide limited protection.

For more DOT Emergency Guidelines (Complete) data for MAGNESIUM PERCHLORATE (8 total), please visit the HSDB record page.

安全と保護具

Fire FightingExcerpt from ERG Guide 140 [Oxidizers]:
Accidental Release Measures · 2 件

· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.

· Keep combustibles (wood, paper, oil, etc.) away from spilled material.

First Aid · 2 件

INHALATION: remove victim to fresh air; get medical attention if irritation persists.

General First Aid:

Exposure Control and Personal Protection· Wear positive pressure self-contained breathing apparatus (SCBA).
Fire Fighting Procedures · 2 件

If material on fire or involved in fire: Flood with water. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible.

Evacuation: If fire becomes uncontrollable - consider evacuation of one-half (1/2) mile radius.

Storage Conditions · 2 件

PROTECT AGAINST PHYSICAL DAMAGE. STORE IN DRY PLACE OF NONCOMBUSTIBLE CONSTRUCTION, SEPARATE FROM COMBUSTIBLE, ORG, READILY OXIDIZABLE MATERIALS, & ACIDS.

Keep tightly closed.

Cleanup MethodsIMMEDIATELY REMOVE & CAREFULLY DISPOSE OF ANY SPILLED PERCHLORATE.
Nonfire Spill ResponseExcerpt from ERG Guide 140 [Oxidizers]:
Disposal Methods · 1 件

SRP: At the time of review, criteria for land treatment or burial (sanitary landfill) disposal practices are subject to significant revision. Prior to implementing land disposal of waste residue (including waste sludge), consult with environmental regulatory agencies for guidance on acceptable disposal practices.

Preventive Measures · 3 件

If material not on fire and not involved in fire: Keep sparks, flames, and other sources of ignition away. Keep material out of water sources and sewers.

Personnel protection: ... Do not handle broken packages unless wearing appropriate personal protective equipment. Wash away any material which may have contacted the body with copious amounts of water or soap and water. Wear positive pressure self-contained breathing apparatus when fighting fires involving this material.

SRP: The scientific literature for the use of contact lenses in industry is conflicting. The benefit or detrimental effects of wearing contact lenses depend not only upon the substance, but also on factors including the form of the substance, characteristics and duration of the exposure, the uses of other eye protection equipment, and the hygiene of the lenses. However, there may be individual substances whose irritating or corrosive properties are such that the wearing of contact lenses would be harmful to the eye. In those specific cases, contact lenses should not be worn. In any event, the usual eye protection equipment should be worn even when contact lenses are in place.

Isolation and Evacuation · 2 件

Excerpt from ERG Guide 140 [Oxidizers]:

Immediate precautionary measure

Minimum Risk LevelChronic Oral: 0.0007 mg/kg/day (L900)

毒性情報

Treatment · 1 件

In case of oral exposure, immediately dilute with 4 to 8 ounces (120 to 240 mol) of water or milk. Consider after ingestion of a potentially life-threatening amount of poison if it can be performed soon after ingestion (generally within 1 hour). Protect airway by placement in Trendelenburg and left lateral decubitus position or by endotracheal intubation. Control any seizures first. Maintain ventilation and oxygenation and evaluate with frequent arterial blood gas or pulse oximetry monitoring. Early use of PEEP and mechanical ventilation may be needed. Following inhalation, Move patient to fresh air. Monitor for respiratory distress. If cough or difficulty breathing develops, evaluate for respiratory tract irritation, bronchitis, or pneumonitis. Administer oxygen and assist ventilation as required. Treat bronchospasm with inhaled beta2 agonist and oral or parenteral corticosteroids. In case of acute lung injury, maintain ventilation and oxygenation and evaluate with frequent arterial blood gas or pulse oximetry monitoring. Following eye exposure, irrigate exposed eyes with copious amounts of room temperature water for at least 15 minutes. Following dermal exposure, remove contaminated clothing and wash exposed area thoroughly with soap and water. A physician may need to examine the area if irritation or pain persists. Treat dermal irritation or burns with standard topical therapy. Patients developing dermal hypersensitivity reactions may require treatment with systemic or topical corticosteroids or antihistamines. (T36)

Health Effects · 1 件

Adverse effects on a wide variety of organ systems can result from disruption in the availability of T3 to target tissues. Organ systems affected by disturbances in T3 levels include the skin, cardiovascular system, pulmonary system, kidneys, gastrointestinal tract, liver, blood, neuromuscular system, central nervous system, skeleton, male and female reproductive systems, and numerous endocrine organs, including the pituitary and adrenal glands. Such an array of secondary potential targets underscores the need to maintain an adequate level of circulating thyroid hormones. Perchlorate, an environmental contaminant, is known to disturb the hypothalamus-pituitary-thyroid (HPT) axis by blocking iodide accumulation in the thyroid. Iodide deficiency can lead to hypothyroidism and goiter (L894, A267).

Adverse EffectsMethemoglobinemia - The presence of increased methemoglobin in the blood; the compound is classified as secondary toxic effect
Exposure RoutesInhalation (L894) ; oral (L894) ; dermal (L894) ; eye contact (L894).
Toxicity Summary · 1 件

The primary and most sensitive target of the perchlorate anion (perchlorate) is the thyroid gland. Perchlorate inhibits the transport of iodide (I-) from the blood into the thyroid follicle cells. The inhibition is thought to be accomplished by perchlorate competitively blocking iodide binding to a carrier, or sodium/iodide symporter (NIS), which catalyzes the simultaneous transfer of Na+ and I-across the basolateral membrane of thyroid follicle cells. Perchlorate inhibition of the NIS can limit the availability of iodide needed for the production of the thyroid hormones thyroxine (T4) and triiodothyronine (T3), which in turn, may affect the circulating levels of T4 and T3. All known effects of perchlorate on the thyroid hormone system derive directly or secondarily from the inhibition of the NIS. T3 is essential for normal development of the nervous system and for the regulation of metabolism of cells in nearly all tissues of the body. Disruption in the availability of T3 in target tissues can result in adverse effects on a wide variety of organs and systems (L894).

Signs and SymptomsIrritating to skin, eyes, and respiratory system, depending on the route of exposure. Esophageal or gastrointestinal tract irritation could occur following exposures (L894).
Carcinogen ClassificationNo indication of carcinogenicity to humans (not listed by IARC).
Antidote and Emergency Treatment · 4 件

Basic treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary ... . Monitor for shock and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with normal saline during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool ... . /Magnesium and Related Compounds/

Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious or in severe respiratory distress. Positive pressure ventilation techniques with a bag valve mask device may be beneficial. Monitor cardiac rhythm and treat arrhythmias if necessary ... . Start an IV with D5W /SRP: "To keep open", minimal flow rate/. Use lactated Ringer's if signs of hypovolemia are present. Watch for signs of fluid overload. Consider drug therapy for pulmonary edema ... . For hypotension with signs of hypovolemia, administer fluid cautiously. Consider vasopressors for hypotension with a normal fluid volume. Watch for signs of fluid overload ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Magnesium and Related Compounds/

Basic treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Anticipate seizures and treat if necessary ... . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with normal saline during transport ... . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool ... . /Chlorates and Related Compounds/

Advanced treatment: Consider orotracheal or nasotracheal intubation for airway control in the patient who is unconscious. Start an IV with D5W /SRP: "To keep open", minimal flow rate/. Use lactated Ringer's if signs of hypovolemia are present. Watch for signs of fluid overload. Treat seizures with diazepam ... . Use proparacaine hydrochloride to assist eye irrigation ... . /Chlorates and Related Compounds/

Non-Human Toxicity ValuesLD50 Mouse intraperitoneal 1500 mg/kg

法規制情報

State Drinking Water Standards · 2 件

(CA) CALIFORNIA 6 ug/L /Perchlorate ion/

(MA) MASSACHUSETTS 2 ug/L /Perchlorate ion/

State Drinking Water Guidelines · 2 件

(CA) CALIFORNIA 6 ug/L /Perchlorate ion/

(ME) MAINE 1 ug/L /Perchlorate ion/

安全データ

F
3-10
wgk
3
tsca
TSCA listed
rtecs
SC8925000
ridadr
UN 1475 (MAGNESIUM PERCHLORATE)
毒性
LD50 ipr-mus: 1500 mg/kg JAFCAU 14,512,66
hs_code
28299010
risk_code
8-36/37/38-14/15
消防法
危-1-PC-1-I
hazard_code
O,Xi
safety_code
17-26-27-36/37/39-43-7/8
hazard_class
5.1
packing_group
II
Hazard Classifications
Eye Irrit. 2Ox. Sol. 2Skin Irrit. 2STOT SE 3
ストレージクラス
5.1A - Strongly oxidizing hazardous materials
有毒物質データの
10034-81-8(Hazardous Substances Data)

使用Magnesium perchlorate is commonly utilized as a potent oxidizing agent. It is used as dehydrating agent in organic synthesis. It is practiced in many domains like pharma industry, pyrotechnics industry,in rechargeable batteries and it is a versatile tool in organic synthesis. It possesses photoelectronic and optical properties. Thus it can be used in photo electronic and optoelectronic devices. It is applied as a strong drying agent for gases.

一般的な説明A white crystalline solid. Strongly absorbs water from air and dissolves in it. Accordingly, used as a regenerable drying agent. May explode under prolonged exposure to heat or fire.

調製方法 · 2 件

製造方法Magnesium perchlorate can be prepared by reacting magnesium carbonate with a solution of perchloric acid: MgCO3+ HClO4→Mg(ClO4)2+ CO2 This salt can also be prepared by an electrochemical method in water whereby magnesium perchlorate is formed from magnesium chlorate in which a platinum anode and a rotating stainless steel cathode are employed.

純化方法Magnesium perchlorate (Anhydrone, Dehydrite) [10034-81-8 (anhydrous)] M 259.2, m >250o, pK2 5

上流・下流製品情報

上流原料

マグネシウムカルボナート過塩素酸塩