펜타플루오로에틸트리플루오로비닐에테르

Perfluoroethyl vinyl ether

HCID 82672

기본 정보

CAS
10493-43-3
표준 SMILES
FC(F)=C(F)OC(F)(F)C(F)(F)F
InChIKey
GWTYBAOENKSFAY-UHFFFAOYSA-N
분자식
C4F8O
평균 분자량
216.03 g/mol
단동위원소 질량
215.98213992

이름 및 식별자

우선 이름
Perfluoroethyl vinyl ether
IUPAC
1,1,1,2,2-pentafluoro-2-(1,2,2-trifluoroethenoxy)ethane
현지명
펜타플루오로에틸트리플루오로비닐에테르
영어명
Pentafluoroethyl trifluorovinyl ether
분자식
C4F8O
분자량
216.03

이름 및 동의어

pentafluoroethyl trifluorovinyl ether10493-43-3perfluoroethyl vinyl etherTrifluoro(pentafluoroethoxy)ethylene1VSV99CMSREINECS 234-018-7Perfluoroethylvinyl etherEthene, trifluoro(pentafluoroethoxy)-DTXSID1075305Ethene, 1,1,2-trifluoro-2-(1,1,2,2,2-pentafluoroethoxy)-ETHER, PENTAFLUOROETHYL TRIFLUOROVINYLRefChem:860249
이름 더 보기
펜타플루오로에틸트리플루오로비닐에테르PEVEperfluoroethylvinyletherOctafluoro-3-oxa-1-pentenePerfluoro(alkylvinylether)Perfluoroethylvinyl Ether (PEVE)trifluoro(pentafluoroethoxy)ethenetrifluoro(pentafluoroethoxy)-ethenether,pentafluoroethyltrifluorovinyl
perfluoro(ethylvinyl ether)DTXCID4032906234-018-71,1,1,2,2-pentafluoro-2-(1,2,2-trifluoroethenoxy)ethanePENTAFLUOROETHYLTRIFLUOROVINYLETHERMFCD02101232Ethene,1,1,2-trifluoro-2-(1,1,2,2,2-pentafluoroethoxy)-1,1,2-TRIFLUORO-2-(1,1,2,2,2-PENTAFLUOROETHOXY)ETHENE

데이터베이스 식별자

CAS
10493-43-3
PubChem CID
82672
DTXSID
DTXSID1075305
UNII
1VSV99CMSR
EC Number
234-018-7
Nikkaji
J212.428I

물성

구조 계산 물성

XLogP
3.1
극성 표면적
9.2 Ų
수소 결합 공여자 수
0
수소 결합 수용자 수
9
회전 가능 결합 수
2
무거운 원자 수
13

실험 및 물리화학적 성질

Physical Description · 2건

Perfluoro(ethylvinyl ether) appears as a colorless gas. Heavier than air. Easily liquefied. Contact with the unconfined liquid may cause frost bite by evaporative cooling. May asphyxiate by displacing air. A flame may flash back from a point of ignition to source of a leak. Under prolonged exposure to fire or heat containers may rupture violently and rocket.

Gas Vapor

물리화학적 성질

끓는 점
7 °C · 7°C
밀도
1.4133 · 1.4133 (estimate)
수용성
2.4 mg/L · 2.4mg/L at 20℃
InChI
InChI=1S/C4F8O/c5-1(6)2(7)13-4(11,12)3(8,9)10
InChIKey
GWTYBAOENKSFAY-UHFFFAOYSA-N
SMILES
C(/F)(\F)=C(/F)\OC(F)(F)C(F)(F)F

안전 및 규제

GHS 분류

GHS Classification · 5건

Danger

H220 (100%): Extremely flammable gas [Danger Flammable gases];H280 (100%): Contains gas under pressure; may explode if heated [Warning Gases under pressure];H332 (16.7%): Harmful if inhaled [Warning Acute toxicity, inhalation]

P203, P210, P222, P261, P271, P280, P304+P340, P317, P377, P381, P403, and P410+P403 (click each P-code to see the statement)

Aggregated GHS information provided per 6 reports by companies from 2 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.;Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown. For more detailed information, please visit ECHA C&L website.

유해성 정보

Regulatory Information · 3건

Ethene, 1,1,2-trifluoro-2-(1,1,2,2,2-pentafluoroethoxy)- is listed on the EPA's Chemical Data Reporting (CDR) system. Manufacturers and importers of Ethene, 1,1,2-trifluoro-2-(1,1,2,2,2-pentafluoroethoxy)- are required to report information about their production and use of this chemical to the EPA under the Toxic Substances Control Act (TSCA). (40 eCFR Part 711)

PMN - indicates a commenced PMN (Pre-Manufacture Notices) substance.

Status: Active Update: 28-09-2021 https://echa.europa.eu/registration-dossier/-/registered-dossier/21612

DOT LabelFlammable Gas
Fire Hazards · 1건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;EXTREMELY FLAMMABLE. Will be easily ignited by heat, sparks or flames. Will form explosive mixtures with air. Vapors from liquefied gas are initially heavier than air and spread along ground. CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966), Methane (UN1971) and Hydrogen and Methane mixture, compressed (UN2034) are lighter than air and will rise. Hydrogen and Deuterium fires are difficult to detect since they burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.) Vapors may travel to source of ignition and flash back. Cylinders exposed to fire may vent and release flammable gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket. CAUTION: When LNG - Liquefied natural gas (UN1972) is released on or near water, product may vaporize explosively. (ERG, 2024)

Health Hazards · 1건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas. Some may be irritating if inhaled at high concentrations. Contact with gas, liquefied gas or cryogenic liquids may cause burns, severe injury and/or frostbite. Fire may produce irritating and/or toxic gases. (ERG, 2024)

Reactive GroupEthers;Hydrocarbons, Aliphatic Unsaturated;Fluorinated Organic Compounds
Reactivity AlertsHighly Flammable;Peroxidizable Compound

안전 및 보호

Fire Fighting · 1건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED. CAUTION: Hydrogen (UN1049), Deuterium (UN1957), Hydrogen, refrigerated liquid (UN1966) and Hydrogen and Methane mixture, compressed (UN2034) will burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.).;SMALL FIRE: Dry chemical or CO2.;LARGE FIRE: Water spray or fog. If it can be done safely, move undamaged containers away from the area around the fire. CAUTION: For LNG - Liquefied natural gas (UN1972) pool fires, DO NOT USE water. Use dry chemical or high-expansion foam.;FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks in direct contact with flames. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2024)

First Aid · 1건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;Refer to the "General First Aid" section. Specific First Aid: Clothing frozen to the skin should be thawed before being removed. In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts. In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing if adhering to skin. (ERG, 2024)

Nonfire Spill Response · 1건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. If possible, turn leaking containers so that gas escapes rather than liquid. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Do not direct water at spill or source of leak. CAUTION: For LNG - Liquefied natural gas (UN1972), DO NOT apply water, regular or alcohol-resistant foam directly on spill. Use a high-expansion foam if available to reduce vapors. Prevent spreading of vapors through sewers, ventilation systems and confined areas. Isolate area until gas has dispersed. CAUTION: When in contact with refrigerated/cryogenic liquids, many materials become brittle and are likely to break without warning. (ERG, 2024)

Isolation and Evacuation · 1건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.;LARGE SPILL: Consider initial downwind evacuation for at least 800 meters (1/2 mile).;FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions. In fires involving Liquefied Petroleum Gases (LPG) (UN1075), Butane (UN1011), Butylene (UN1012), Isobutylene (UN1055), Propylene (UN1077), Isobutane (UN1969), and Propane (UN1978), also refer to the "BLEVE - Safety Precautions" section. (ERG, 2024)

Personal Protective Equipment (PPE) · 1건

Excerpt from ERG Guide 115 [Gases - Flammable (Including Refrigerated Liquids)]:;Wear positive pressure self-contained breathing apparatus (SCBA). Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. Always wear thermal protective clothing when handling refrigerated/cryogenic liquids. (ERG, 2024)

규제 정보

Regulatory Information · 3건

Ethene, 1,1,2-trifluoro-2-(1,1,2,2,2-pentafluoroethoxy)- is listed on the EPA's Chemical Data Reporting (CDR) system. Manufacturers and importers of Ethene, 1,1,2-trifluoro-2-(1,1,2,2,2-pentafluoroethoxy)- are required to report information about their production and use of this chemical to the EPA under the Toxic Substances Control Act (TSCA). (40 eCFR Part 711)

PMN - indicates a commenced PMN (Pre-Manufacture Notices) substance.

Status: Active Update: 28-09-2021 https://echa.europa.eu/registration-dossier/-/registered-dossier/21612

안전 데이터

tsca
TSCA listed
ridadr
UN 3154
HS 번호
2909199090
risk_code
11
hazard_code
Xi,F
safety_code
9-16-33

화학 및 산업

용도 및 제조

U.S. Production2023: 250,000 - <550,000 lb;2022: 250,000 - <550,000 lb;2021: 250,000 - <550,000 lb;2020: 250,000 - <550,000 lb
Industry UsesMonomers
Use ClassificationPFAS (per- and polyfluoroalkyl substances) -> OECD Category
General Manufacturing Information · 2건

Plastics Material and Resin Manufacturing

Ethene, 1,1,2-trifluoro-2-(1,1,2,2,2-pentafluoroethoxy)-: ACTIVE

응용 분야 · 1건

일반 설명A colorless gas. Heavier than air. Easily liquefied. Contact with the unconfined liquid may cause frost bite by evaporative cooling. May asphyxiate by displacing air. A flame may flash back from a point of ignition to source of a leak. Under prolonged exposure to fire or heat containers may rupture violently and rocket.

공급사46 곳

上海恩氟佳科技有限公司15800445152 · [email protected]
广州纳珑化工有限公司13192879270; 13192879270 · [email protected]
上海比阳实业有限公司+86-21-52699951; +8613917686115 · [email protected]
杭州摩库生物医药科技有限公司+86-057181025280; +8617767106207 · [email protected]
陕西缔都新材料有限公司029-63373950 17392216152 · [email protected]

관련 반응

2건

화합물 노트

불러오는 중…