HRID1373353

反应详情

EQUATION

反应方程式

HRID 1373353 的结构方程式

AUXILIARIES

试剂、催化剂与溶剂

3

PROCEDURE

实验过程

In a nitrogen atmosphere at room temperature, 600 ml of a cyclohexane solution containing 20 g of norbornene was placed in a 1-liter stainless steel autoclave purged thoroughly with nitrogen. 0.6 mmol of triisobutylaluminum was added, and nitrogen in the autoclave was replaced with ethylene. The inside of the autoclave was pressurized with ethylene, and then the temperature in the autoclave was raised so that the temperature and the pressure in the autoclave were 70° C. and 0.7 MPa, respectively. 12.8 ml of the above catalyst solution was forced into the autoclave with pressurized nitrogen to initiate the polymerization. After the initiation of the polymerization, with supplying only ethylene, the polymerization was conducted at a pressure of 0.7 MPa and a temperature of 70° C. for 5 min. After 5 min from the initiation of the polymerization, 5 ml of isopropanol (IPA) was forced into the autoclave with pressurized nitrogen to terminate the polymerization. After decompression, the polymer solution was taken out. With vigorously agitating by a homomixer, the polymer solution was brought into contact with an aqueous solution prepared by adding 5 ml of concentrated hydrochloric acid based on 1 liter of water at a ratio of 1 to 1, and the catalyst residue was passed into the water phase. The contacted mixed solution was allowed to stand still, and then the water phase was removed. The polymer solution was washed twice with water to purify the same, and the phase of the polymer solution was separated. The purified and separated polymer solution was allowed to contact with acetone, which was three times as much as the polymer solution, with vigorously agitating. After the precipitation of the copolymer, the solid product (copolymer) was collected by filtration and was thoroughly washed with acetone. To extract unreacted norbornene remained in the polymer, the solid product was put in acetone so as to be a concentration of 40 g/liter, and the extraction was conducted at 60° C. for 2 hr. After the extraction, the solid product was collected by filtration and was dried under reduced pressure in flowing nitrogen at 130° C. and 350 mmHg for 12 hr.

WORKUP

后处理

  1. custompurged thoroughly with nitrogen
  2. temperaturethe temperature in the autoclave was raised so that the temperature
  3. customwere 70° C.
  4. customthe polymerization
  5. customAfter the initiation of the polymerization
  6. customto terminate
  7. customthe polymerization
  8. customprepared
  9. additionThe contacted mixed solution
  10. customthe water phase was removed
  11. washThe polymer solution was washed twice with water
  12. customto purify the same, and the phase of the polymer solution
  13. customwas separated
  14. customThe purified
  15. customseparated polymer solution
  16. stirringwith vigorously agitating
  17. customAfter the precipitation of the copolymer
  18. filtrationthe solid product (copolymer) was collected by filtration
  19. washwas thoroughly washed with acetone
  20. extractionTo extract unreacted norbornene
  21. extractionthe extraction
  22. waitwas conducted at 60° C. for 2 hr
  23. extractionAfter the extraction
  24. filtrationthe solid product was collected by filtration
  25. customwas dried under reduced pressure
  26. customat 130° C.
  27. wait350 mmHg for 12 hr