Back
HuagongsheHuagongshe Chemistry Print Report · For research reference only
HRID 1729122Generated: October 26, 2026

Nitrate → Nitrate

https://huagongshe.com/reaction/1729122

Reaction equation

Participants

RoleNameHCIDCharge
ReactantNitrateHCID 943—
ReactantOxalic AcidHCID 971—
ReactantOxalic acid dihydrateHCID 61373—
ReactantEuropium oxideHCID 159371—
ReactantYttrium oxideHCID 159374—
ReactantAzane;hydrateHCID 12896473—
SolventNitric AcidHCID 944—
SolventWaterHCID 962—
ProductNitrateHCID 943—
ProductOxalic AcidHCID 971—
ProductEuropiumHCID 23981—
ProductYttriumHCID 23993—

Reaction Conditions

Temperature60 °C

Reaction Steps

A mixed rare earth nitrate aqueous solution was prepared by dissolving 94.5 g of yttrium oxide and 5.5 g of europium oxide in 200 ml of a concentrated nitric acid followed by the addition of water to make up a volume of 3.3 liters. Separately, an aqueous ammoniacal oxalic acid solution was prepared by dissolving 240 g of oxalic acid dihydrate in 6.6 liters of water and adding 290 ml of a 28% ammonia water thereto. The mixed rare earth nitrate solution cooled to room temperature was added gradually to this oxalic acid solution under agitation at room temperature taking 20 minutes and agitation was further continued for additional 10 minutes. The pH value of the aqueous medium was 2.0. The precipitate thus formed was collected by filtration under suction and repeatedly washed with deionized water until no nitrate ions could be detected in the washing taking 1.5 hours as measured from the start of the precipitation reaction. The precipitate after washing was added to 8 liters of deionized water at 50° C. and dispersed therein by agitation and the dispersion was agitated for 4 hours at 60° C. The dispersion was filtered to collect the precipitate which was dried and calcined for 2 hours at 900° C. to give a powder of mixed rare earth oxide of yttrium and europium. This oxide powder was examined by the scanning electron microscopy to find that the particles mostly has a polyhedral configuration. The powder had a specific surface area of 6.8 m2 /g as determined by using an instrument Flow Souve 2300 (manufactured by Micromeritex Co.), an average particle diameter of 1.71 μm as determined by using a Fischer Subsieve Sizer Model 95 (manufactured by Fischer Co.) and a QD value of 0.20 calculated from a cumulative particle volume distribution curve prepared by using the histogram of the volume fractions of particles obtained by using a Coulter Model TA-II (manufactured by Coulter Electronics Co.) and shown in FIG. 1 of the accompanying drawing.

Provenance & Evidence

DOI10.6084/m9.figshare.5104873.v1
Patent numberUS05332558
Source datasetuspto-grants-1994_07
ORD IDord-8ad4360a9e9844a289a98f2cec7c1da6
Source noteuspto-grants-1994_07