Triethylamine → 3-(3-(methylsulfonamido)pyridin-4-yl)-N-(2-phenylpropan-2-yl)benzamide

HRID 219315Notes

Reaction equation

HRID 219315 reaction equation
[NH2:1][C:2]1[CH:3]=[N:4][CH:5]=[CH:6][C:7]=1[C:8]1[CH:9]=[C:10]([CH:23]=[CH:24][CH:25]=1)[C:11]([NH:13][C:14]([C:17]1[CH:22]=[CH:21][CH:20]=[CH:19][CH:18]=1)([CH3:16])[CH3:15])=[O:12].C(N(CC)CC)C.[CH3:33][S:34](Cl)(=[O:36])=[O:35].[F-].C([N+](CCCC)(CCCC)CCCC)CCC>ClCCl.C1COCC1>[CH3:33][S:34]([NH:1][C:2]1[CH:3]=[N:4][CH:5]=[CH:6][C:7]=1[C:8]1[CH:9]=[C:10]([CH:23]=[CH:24][CH:25]=1)[C:11]([NH:13][C:14]([C:17]1[CH:22]=[CH:21][CH:20]=[CH:19][CH:18]=1)([CH3:16])[CH3:15])=[O:12])(=[O:36])=[O:35]

Participants

7

Procedure

To a solution containing 3-(3-aminopyridin-4-yl)-N-(2-phenylpropan-2-yl)benzamide (1.7 g, 5.1 mmol), triethylamine (5.2 g, 51.3 mmol), and dichloromethane (85 mL) was added methanesulfonylchloride (0.90 mL, 11.3 mmol) in dichloromethane (75 mL) dropwise over 3 min. The solution was maintained at room temperature for 1 h and concentrated to remove all solvent. The residue thus obtained was dissolved in THF (51 mL) and tetrabutylammoniumfluoride (24 mL, 1.0 M in THF) was added in a steady stream via syringe. The solution was maintained at 60° C. for 18 h, concentrated and dissolved in ethyl acetate (75 mL). The solution was washed with water (5×50 mL), washed with brine (50 mL), dried over MgSO4, filtered and concentrated. Purification on silica gel (0-8% methanol/dichloromethane, 60 min gradient) afforded 3-(3-(methylsulfonamido)pyridin-4-yl)-N-(2-phenylpropan-2-yl)benzamide as a pale yellow foam. 1H NMR (500 MHz, DMSO-D6) δ ppm 9.42 (s, 1H), 8.64 (s, 1H), 8.56 (d, J=4.88 Hz, 1H), 8.45 (s, 1H), 8.03 (s, 1H), 7.90 (d, J=7.63 Hz, 1H), 7.71 (d, J=7.63-7.63 Hz, 1H), 7.58 (t, J=7.78 Hz, 1H), 7.49 (d, J=4.88 Hz, 1H), 7.40 (d, J=7.93 Hz, 2H), 7.29 (t, J=7.63 Hz, 2H), 7.17 (t, J=7.17 Hz, 1H), 2.85 (s, 3H), 1.69 (s, 6H). LCMS: retention time: 1.277 min. LC data was recorded on a Shimadzu LC-10AS liquid chromatograph equipped with a Waters-Sunfire, 5u, C18, 4.6×50 mm column using a SPD-10AV LTV-Vis detector at a detector wave length of 220 nM. The elution conditions employed a flow rate of 4 mL/min, a gradient of 100% solvent A/0% solvent B to 0% solvent A/100% solvent B, a gradient time of 3 min, a hold time of 1 min, and an analysis time of 4 mM where solvent A was 10% CH3CN/90% H2O/10 mM TFA and solvent B was 10% H2O/90% CH3CN/10 mM TFA. MS data was determined using a Micromass Platform for LC in electrospray mode. m/z 410 (MH+).

Workup

  1. concentrationconcentrated
  2. customto remove all solvent
  3. customThe residue thus obtained
  4. temperatureThe solution was maintained at 60° C. for 18 h
  5. concentrationconcentrated
  6. dissolutiondissolved in ethyl acetate (75 mL)
  7. washThe solution was washed with water (5×50 mL)
  8. washwashed with brine (50 mL)
  9. dry with materialdried over MgSO4
  10. filtrationfiltered
  11. concentrationconcentrated
  12. customPurification on silica gel (0-8% methanol/dichloromethane, 60 min gradient)

Sources & evidence

ORD record
ord-6a7655a749fd4082961b4c472c1a22cd
Source dataset
uspto-grants-2012_06
Patent number
US08198449B2

Reaction notes

Loading…