Back
HuagongsheHuagongshe Chemistry Print Report · For research reference only
HRID 269706Generated: October 25, 2026

1,5-Naphthalenedisulfonic acid → Phosphate

https://huagongshe.com/reaction/269706

Reaction equation

Participants

RoleNameHCIDCharge
Reactant1,5-Naphthalenedisulfonic acidHCID 6666—
ReactantSodium HydroxideHCID 14798—
ReactantSodium TripolyphosphateHCID 24455—
ReactantDisodiumHCID 141233—
ReactantDisodium naphthalene disulfonic acidHCID 87774290—
ReactantCID 131727175HCID 131727175—
SolventWaterHCID 962—
ProductPhosphateHCID 1061—
ProductTriphosphateHCID 3440921—

Reaction Steps

Here is an example of the use of 1,5 naphthalenedisulfonic acid, disodium salt at a coal-fired power plant. The 1,5 naphthalenedisulfonic acid was applied to the high-pressure steam generator operating at 2000 psig (636° F.). The 1,5 naphthalenedisulfonic acid, disodium salt was added in combination with sodium/phosphate-based program. The treatment was supplied to the boiler by diluting a liquid product in a daytank and pumping the resulting dilute solution into the chemical injection line in the steam drum of the boiler. Sodium hydroxide was added to the tank as needed to control boiler pH. The liquid product contained sodium tripolyphosphate and disodium naphthalene disulfonic acid dissolved in deionized water. The mass ratio of sodium tripolyphosphate to disodium naphthalene disulfonic acid in the liquid product was 28:1. The tripolyphosphate ion hydrolyses immediately in the high temperature boiler conditions to produce orthophosphate ion PO4. The orthophosphate ion was analyzed by various wet chemistry and spectroscopic techniques in the boiler water. The fluorometers measuring the naphthalene disulfonic acid fluorescence were calibrated to read directly in ppm orthophosphate based on the ratio of sodium tripolyphosphate to disodium naphthalene disulfonic acid in the liquid product. This fluorometer calibration allowed for a direct comparison of the data from the orthophosphate tests and the fluorometric readings. If the orthophosphate test data differed from the fluorometric readings that would be evidence of a chemical reaction that had changed the ratio of phosphate to fluorophore in the boiler water as compared to the ratio found in the original liquid product injected into the boiler. FIG. 2 shows the 1,5 naphthalenedisulfonic acid, disodium salt and PO4 readings, both in terms of ppm PO4 over eighty day time period.

Provenance & Evidence

DOI10.6084/m9.figshare.5104873.v1
Patent numberUS07448255B2
Source datasetuspto-grants-2008_11
ORD IDord-04bbc27c5ca84264a7efe1e4081bf493
Source noteuspto-grants-2008_11