HRID330095

反应详情

EQUATION

反应方程式

HRID 330095 的结构方程式

AUXILIARIES

试剂、催化剂与溶剂

1

PROCEDURE

实验过程

An ion exchange column is prepared by filling a glass column with 380 mL of AmberliteRIRA-68. The resin is rinsed with a dilute ammonia solution, 140 mL ammonium hydroxide in 3 L water, followed by deionized water to a neutral pH, (about 2 L). A 1 N solution of (1-aminomethyl)-cyclohexaneacetic acid hydrochloride is prepared by dissolving 64.6 g of (1-aminomethyl)-cyclohexaneacetic acid hydrochloride hydrate (4:4:1) in 310 mL of deionized water. This solution is filtered through a filter to remove any insoluble material or extracted with an organic solvent such as dichloromethane.

WORKUP

后处理

  1. customAn ion exchange column is prepared
  2. washThe resin is rinsed with a dilute ammonia solution, 140 mL ammonium hydroxide in 3 L water
  3. filtrationThis solution is filtered through
  4. filtrationa filter
  5. customto remove any insoluble material
  6. extractionextracted with an organic solvent such as dichloromethane