HomeMCPWorkbenchSkills
HomeWorkbenchNotificationsMe
llms.txt · MCP GuidePrivacy Policy · Terms of Service · Supportv1.8.3
  1. Home
  2. /Reaction

Morpholine → 4-(6-Bromoquinolin-4-yl)morpholine

HRID 2284618
Print

Reaction equation

HRID 2284618 reaction equation
[Br:1][C:2]1[CH:3]=[C:4]2[C:9](=[CH:10][CH:11]=1)[N:8]=[CH:7][CH:6]=[C:5]2Cl.[NH:13]1[CH2:18][CH2:17][O:16][CH2:15][CH2:14]1.C([O-])([O-])=O.[K+].[K+]>CN1C(=O)CCC1.O>[Br:1][C:2]1[CH:3]=[C:4]2[C:9](=[CH:10][CH:11]=1)[N:8]=[CH:7][CH:6]=[C:5]2[N:13]1[CH2:18][CH2:17][O:16][CH2:15][CH2:14]1
ParticipantsProcedureWorkupSources & evidenceReaction notes

Participants

6

Reactant 3

HCID 8083MorpholineHCID 11430Potassium CarbonateHCID 51395376-Bromo-4-chloroquinoline

Product 1

HCID 220314084-(6-Bromoquinolin-4-yl)morpholineYield 58.2%

Reagents, catalysts & solvents 2

HCID 962WaterSolvent
HCID 13387
N-methyl-2-pyrrolidone
Solvent

Procedure

6-Bromo-4-chloroquinoline (1.0 G, 4.1 mmol), morpholine (0.468 g, 5.3 mmol) and K2CO3 (1.0 G, 7.2 mmol) in NMP (5 mL) were heated at 100° C. for 12 h. The reaction mixture was cooled to room temperature, diluted with water (20 mL) and the product was extracted into EtOAc/hexanes (140 mL/60 mL). The organic layer was washed with water (75 mL) and brine (20 mL) successively, dried over MgSO4 and filtered. The filtrate was concentrated and purified by flash column chromatography (Combiflash® companion System® with RediSep® silica gel column 40 g and 30-70% EtOAC/hexanes as an eluting solvent]. The product fractions were concentrated to provide 4-(6-bromoquinolin-4-yl)morpholine (700 mg) as a white solid. 1H NMR (300 MHz, DMSO-d6) δ 8.73 (d, J=5.0 Hz, 1H), 8.13 (d, J=2.2 Hz, 1H), 7.90 (d, J=8.9 Hz, 1H), 7.81 (dd, J=9.0, 2.2 Hz, 1H), 7.06 (d, J=5.0 Hz, 1H), 3.87-3.84 (m, 4H), 3.18-3.02 (m, 4H).

Workup

  1. extractionthe product was extracted into EtOAc/hexanes (140 mL/60 mL)
  2. washThe organic layer was washed with water (75 mL) and brine (20 mL) successively
  3. dry with materialdried over MgSO4
  4. filtrationfiltered
  5. concentrationThe filtrate was concentrated
  6. custompurified by flash column chromatography (Combiflash® companion System® with RediSep® silica gel column 40 g and 30-70% EtOAC/hexanes as an eluting solvent]
  7. concentrationThe product fractions were concentrated

Sources & evidence

ORD record
ord-eac667dd0dc4450da7de12aca07d5ad0
Source dataset
uspto-grants-2015_09
DOI
10.6084/m9.figshare.5104873.v1
Patent number
US09145433B2

Reaction notes

On this pageParticipantsProcedureWorkupSources & evidenceReaction notes