기본 정보
- 표준 SMILES
[O-][Cl+3]([O-])([O-])O- InChIKey
VLTRZXGMWDSKGL-UHFFFAOYSA-N- 분자식
- ClHO4
- 평균 분자량
- 100.46 g/mol
- 단동위원소 질량
- 99.95633619
개요
Perchloric acid, with more than 50% but not more than 72% acid appears as a clear colorless odorless aqueous solution. Corrosive to metals and tissue. Closed containers may rupture violently under prolonged exposure to heat.
이름 및 식별자
- 우선 이름
- Perchloric Acid
- IUPAC
- perchloric acid
- 현지명
- 과염소산
- 영어명
- PERCHLORIC ACID
- 분자식
- ClHO4
- 분자량
- 100.46
이름 및 동의어
이름 더 보기
데이터베이스 식별자
- CAS
7601-90-3- PubChem CID
- 24247
- DTXSID
DTXSID8047004- ChEBI
CHEBI:29221- UNII
- V561V90BG2
- EC Number
- 231-512-4
- Nikkaji
- J43.590B
물성
구조 계산 물성
- XLogP
- 2.3
- 극성 표면적
- 71.4 Ų
- 수소 결합 공여자 수
- 1
- 수소 결합 수용자 수
- 4
- 회전 가능 결합 수
- 0
- 무거운 원자 수
- 5
- 형식 전하
- 0
- 복잡도
- 114
실험 및 물리화학적 성질
Chemical Classes
Toxic Gases & Vapors -> Oxidizers
Reactive agents - 3rd degree
Density
1.6 to 1.7 at 77 °F (USCG, 1999)
1.768 @ 22 °C
VERY HYGROSCOPIC; COMBINES VIGOROUSLY WITH WATER WITH EVOLUTION OF HEAT; AQ ACID IS VERY CAUSTIC; DECOMP WHEN DISTILLED @ ATMOSPHERIC PRESSURE; DENSITY OF AQ SOLN @ 25 °C: 65.0%= 1.597; 70.0%= 1.664; 75.0%= 1.731; DENSITY OF AQ SOLN @ 15 °C: 1%= 1.0050; 10%= 1.0597; 20%= 1.1279; 30%= 1.2067; 40%= 1.2991; 50%= 1.4103; 60%= 1.5389; 70%= 1.6736
Relative density (water = 1): 1.76 (22 °C)
1.77 @25 °C
Solubility
MISCIBLE IN COLD WATER
Solubility in water: miscible
Melting Point
-170 °F (USCG, 1999)
-112 °C
-112 °C
-112 °C
Physical Description
Perchloric acid, with more than 50% but not more than 72% acid appears as a clear colorless odorless aqueous solution. Corrosive to metals and tissue. Closed containers may rupture violently under prolonged exposure to heat.
Perchloric acid, with not more than 50% acid appears as a clear colorless odorless aqueous solution. Corrosive to metals and tissue. Closed containers may rupture violently under prolonged exposure to heat.
Colorless, odorless oily liquid; [HSDB] Highly hygroscopic; [Merck Index]
COLOURLESS LIQUID WITH PUNGENT ODOUR.
Stability/Shelf Life
VOLATILE
ON STORAGE EVEN IN DARK, ANHYDROUS ACID BECOMES DISCOLORED OWING TO DECOMPOSITION PRODUCTS & MAY EXPLODE SPONTANEOUSLY
UNSTABLE IN CONCENTRATED FORM
fuming
물리화학적 성질
- 녹는점
- -18 °C · -18 °C
- 끓는 점
- 203 °C · 203 °C
- 밀도
- 1.664 g/mL · 1.664 g/mL at 25 °C
- 증기 밀도
- 2.1 · ~2.1 (vs air)
- 증기압
- 6.8 mm · 6.8 mm Hg ( 25 °C)
- 굴절률
- 1.419 · 1.419
- 인화점
- 104 °F · 104 °F
- 저장 조건
- Flammables area
- 용해도
- 물 (난용성)
- 산도 계수 (pKa)
- -7 · -7[at 20 ℃]
- 물리적 상태
- 액체
- 색상
- 10 · APHA: ≤10
- Specific Gravity
- 1.54 · approximate 1.54
- 냄새
- 냄새 없는
- 수소이온지수(pH)
- 0.1 · 0.1 (H2O, 20°C)
- 수용성
- 물과 섞일 수 있습니다.
- Merck
- 14 · 14,7153
- Henry's Law Constant
- 9.9 · 9.9×103 mol/(m3Pa) at 25℃, Jaeglé et al. (1996)
- 안정성
- Stable. Avoid heat. May form explosive peroxides. Incompatible with a wide variety of substances, including organic materials, alcohols, amines, strong acids, strong bases, acid anhydrides, finely powdered metals, strong reducing agents. Contact with wood, paper and other celullose products may lead to explosion, as may contact with a vari
- InChI
- 1S/ClHO4/c2-1(3,4)5/h(H,2,3,4,5)
- InChIKey
- VLTRZXGMWDSKGL-UHFFFAOYSA-N
- SMILES
- OCl(=O)(=O)=O
- LogP
- -4.62 · -4.62
- NIST
- Perchloric acid(7601-90-3)
- EPA
- Perchloric acid (7601-90-3)
화학적 성질
Perchloric acid, HCIO4, also known as Fraude's reagent,is a colorless, fuming,hygroscopic liquid that boils at 16°C(61OF). It is a strong oxidizer and is soluble in water. Cold dilute perchloric acid reacts with metals such as zinc and iron to yield hydrogen gas and the metallic perchlorate. Perchloric acid is used in electrolytic baths, electropolishing, explosives, analytical chemistry, and medicine.
안전 및 규제
GHS 분류
GHS Classification
Danger
H271: May cause fire or explosion; strong Oxidizer [Danger Oxidizing liquids; Oxidizing solids]
P210, P220, P260, P264, P280, P283, P301+P330+P331, P302+P361+P354, P304+P340, P305+P354+P338, P306+P360, P316, P321, P363, P370+P378, P371+P380+P375, P405, P420, and P501 (click each P-code to see the statement)
Danger
H271 (100%): May cause fire or explosion; strong Oxidizer [Danger Oxidizing liquids; Oxidizing solids]
P210, P220, P234, P260, P264, P270, P280, P283, P301+P317, P301+P330+P331, P302+P361+P354, P304+P340, P305+P354+P338, P306+P360, P316, P321, P330, P363, P370+P378, P371+P380+P375, P390, P405, P406, P420, and P501 (click each P-code to see the statement)
유해성 정보
Regulatory Information
Chemical: Perchloric acid
Status: Active Update: 30-05-2018 https://echa.europa.eu/registration-dossier/-/registered-dossier/8872
Perchloric acid: Does not have an individual approval but may be used under an appropriate group standard
The New Jersey Worker and Community Right to Know Act requires public and private employers to provide information about hazardous substances at their workplaces. (N.J.S.A. 34:5A-1 et. seq.)
DOT Label
Oxidizer Corrosive
Corrosive Oxidizer
Fire Hazards
Behavior in Fire: Above 160 °C (320 °F) will react with combustible material and increase intensity of fire. Containers may explode. (USCG, 1999)
Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:
· May explode from friction, heat or contamination.
· Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes.
Not combustible but enhances combustion of other substances. Many reactions may cause fire or explosion. Gives off irritating or toxic fumes (or gases) in a fire. Risk of fire and explosion on contact with metals, reducing agents or organic materials.
Fire Potential
AQ ACID...MAY DEFLAGRATE IN CONTACT WITH OXIDIZABLE SUBSTANCES. /AQUEOUS SOLN/
WILL INCREASE THE INTENSITY OF A FIRE. MAY CAUSE FIRE ON CONTACT WITH COMBUSTIBLES. /AQUEOUS SOLN/
ANHYDROUS ACID IGNITES IN CONTACT WITH SODIUM IODIDE OR HYDRIODIC ACID. ...MIXTURES OF 2-METHYLPROPENE & PERCHLORIC ACID VAPOR (5:1 MOLAR) IN NITROGEN IGNITE SPONTANEOUSLY @ 250 °C.
ANHYDROUS ACID IGNITES SULFINYL CHLORIDE.
...will ignite...by shock or heat.
Health Hazards
Inhalation of vapors or mist causes burning sensation of nose and throat, and lung irritation with coughing; prolonged or excessive exposure could cause vomiting and severe coughing. Ingestion causes blistering and burns of mouth and stomach. Contact with eyes or skin causes blistering and burns. (USCG, 1999)
Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:
· TOXIC; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death.
· TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance may cause severe injury, burns or death.
Hazards Summary
Highly corrosive to skin; [Quick CPC] High inhalation exposure can cause pneumonitis and pulmonary edema; Causes liver injury in high-dose animal studies; [HSDB] Evolves heat when mixed with water--may explode; [Merck Index] A strong oxidant--a fire and explosion hazard; Corrosive to skin, eyes, and respiratory tract; Inhalation may cause pulmonary edema; [ICSC]
DOT ID and Guide
1873 143
1802 157
Reactive Group
Acids, Strong Oxidizing
Acids, Strong Oxidizing
Special Reports
A REVIEW OF THE TOXICITY & HEALTH HAZARD OF PERCHLORIC ACID (17 REFERENCES).[MOREL C ET AL; TOXICOLOGICAL PAPER, NO 141: PERCHLORIC ACID (HCLO4); CAH NOTES DOC 94: 173-6 (1979)]
This data sheet describes the hazards of perchloric acid and the procedures necessary to avoid physical harm. Contents: Properties; uses; containers; shipping regulations; storage; personal hazards; handling; personal protective equipment; ventilation; fire and explosion hazards; symptoms of poisoning; first aid; toxicity; medical examinations; waste disposal.[Perchloric acid; National Safety Council, 444 North Michigan Ave, Chicago, IL 60611, USA, 4 pages (1982)]
안전 및 보호
Fire Fighting
Excerpt from ERG Guide 143 [Oxidizers (Unstable)]:
Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:
In case of fire in the surroundings: water in large amounts, water spray. In case of fire: keep drums, etc., cool by spraying with water. Combat fire from a sheltered position.
First Aid Measures
Fresh air, rest. Half-upright position. Artificial respiration may be needed. Refer for medical attention.
Remove contaminated clothes. Rinse skin with plenty of water or shower. Refer for medical attention .
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Rinse mouth. Do NOT induce vomiting. Refer for medical attention .
Accidental Release Measures
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
· Keep combustibles (wood, paper, oil, etc.) away from spilled material.
· CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
· ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area.
First Aid
Get medical attention following all exposures to this compound.
Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:
General First Aid:
General First Aid:
Exposure Control and Personal Protection
· Wear positive pressure self-contained breathing apparatus (SCBA).
· Wear positive pressure self-contained breathing apparatus (SCBA).
Fire Fighting Procedures
COMBAT FIRES FROM SAFE DISTANCE OR PROTECTED LOCATION. FLOOD DISCHARGE AREA WITH WATER. COOL EXPOSED CONTAINERS WITH WATER. /AQUEOUS SOLN/
USE WATER SPRAY.
Storage Conditions
REAGENT BOTTLE--MAX 1-LB, GLASS-STOPPERED, GLASS BOTTLE; KEPT IN A HEAVY GLASS TRAY WITH LARGER CAPACITY. ADDN LAB STORAGE SHOULD BE IN ORIGINAL BOTTLES INSIDE A GLASS CONTAINER PADDED WITH GLASS WOOL & HAVING GREATER CAPACITY THAN THE CONTAINER. CARBOYS & LARGE BOTTLES SHOULD BE STORED ON ACID-RESISTING NONCOMBUSTIBLE SHELVES, IN A NONCOMBUSTIBLE STRUCTURE. ALL STORAGE MUST BE SEPARATED FROM COMBUSTIBLE MATERIALS, ORG MATERIALS, STRONG DEHYDRATING AGENTS, OXIDIZING & REDUCING AGENTS. ...MUST BE STORED WHERE IT WILL NOT FREEZE... PROTECT AGAINST PHYSICAL DAMAGE. ELECTRICAL WIRING...IN STORAGE AREAS MUST BE OF WATERTIGHT TYPE TO PROTECT AGAINST CORROSIVE ACTION OF VAPORS.
...SHOULD BE STORED & USED IN GLASS OR OTHER INERT CONTAINERS (PREFERABLY UNBREAKABLE), & CORKS & RUBBER STOPPERS SHOULD NOT BE USED.
Cleanup Methods
NEUTRALIZING AGENTS FOR ACIDS & CAUSTICS: FLUSH WITH WATER & RINSE WITH DILUTE SODIUM BICARBONATE OR SODA ASH SOLUTION.
REMOVE SPILLED PERCHLORIC ACID BY IMMEDIATE & THOROUGH WASHING WITH LARGE AMT OF WATER.
RADIOACTIVE WASTEWATER CONTAINING PERCHLORIC ACID IS TREATED BY SN, TI3+ OR MOO3, & AQ HCL. AFTER 2 HR 92.3% OF PERCHLORIC ACID WAS REDUCED.
Nonfire Spill Response
Excerpt from ERG Guide 143 [Oxidizers (Unstable)]:
Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:
Disposal Methods
SRP: At the time of review, criteria for land treatment or burial (sanitary landfill) disposal practices are subject to significant revision. Prior to implementing land disposal of waste residue (including waste sludge), consult with environmental regulatory agencies for guidance on acceptable disposal practices.
Neutralization, landfill, & discharge to sewer: Reduce perchloric acid with weak reducing agent (hypobisulfite or ferrous salt, plus sulfuric acid as accelerator have been recommended), neutralize with sodium carbonate or calcium oxide. The reduced neutralized slurry may be flushed to the drain with high dilution; otherwise deposit in an approved landfill.
독성 정보
Signs and Symptoms
Sore throat. Burning sensation. Cough. Laboured breathing. Symptoms may be delayed.
Redness. Pain. Serious skin burns.
Redness. Pain. Loss of vision. Severe deep burns.
Sore throat. Abdominal pain. Burning sensation. Diarrhoea. Shock or collapse. Vomiting.
Human Toxicity Excerpts
SYMPTOMATOLOGY (...INGESTION OR SKIN CONTACT): 1. CORROSION OF MUCOUS MEMBRANES OF MOUTH, THROAT AND ESOPHAGUS, WITH IMMEDIATE PAIN AND DYSPHAGIA. NECROTIC AREAS...GRAYISH WHITE BUT SOON ACQUIRE A BLACKISH DISCOLORATION (YELLOW IN CASE OF NITRIC ACID) & SOMETIMES SHRUNKEN OR WRINKLED TEXTURE... 2. EPIGASTRIC PAIN...MAY BE ASSOC WITH NAUSEA & VOMITING... AT TIMES, GASTRIC HEMORRHAGE MAY BE INTENSE, AND VOMITUS THEN CONTAINS FRESH BLOOD. PROFOUND THIRST. 3. ULCERATION OF ALL MEMBRANES AND TISSUES WITH WHICH THE ACID COMES IN CONTACT. AFTER THE INGESTION OF CONCN MINERAL ACID, THIS CORROSION MAY LEAD WITHIN A FEW HR OR A FEW DAYS TO GASTRIC PERFORATION AND PERITONITIS. 4. CIRCULATORY COLLAPSE WITH CLAMMY SKIN, WEAK & RAPID PULSE, SHALLOW RESP, AND SCANTY URINE. CIRCULATORY SHOCK IS OFTEN IMMEDIATE CAUSE OF DEATH. /ACIDS/
규제 정보
State Drinking Water Standards
(CA) CALIFORNIA 6 ug/L /Perchlorate ion/
(MA) MASSACHUSETTS 2 ug/L /Perchlorate ion/
State Drinking Water Guidelines
(CA) CALIFORNIA 6 ug/L /Perchlorate ion/
(ME) MAINE 1 ug/L /Perchlorate ion/
안전 데이터
- wgk
- 1
- tsca
- TSCA listed
- rtecs
- SC7500000
- ridadr
- UN 1873 5.1/PG I (PERCHLORIC ACID with more than 50 % but not more than 72 % acid, by mass)
- 독성
- LD50 oral (rat) 1100 mg/kg LD50 oral (dog) 400 mg/kg
- HS 번호
- 3822 00 00
- risk_code
- 5-8-35-10-34-36/38
- hazard_code
- C,O,Xi
- safety_code
- 23-26-36-45-36/37/39
- 포장분류
- II
- 위험 등급
- 8
- 기존화학 물질
- KE-28137
- F 고인화성물질
- 3
- 자연 발화 온도
- 485 °C
- Hazard Classifications
- Acute Tox. 4 OralEye Dam. 1Met. Corr. 1Ox. Liq. 1Skin Corr. 1ASTOT RE 2
- 스토리지 클래스
- 5.1A - Strongly oxidizing hazardous materials
- 유해 물질 데이터
- 7601-90-3(Hazardous Substances Data)
화학 및 산업
용도 및 제조
Uses
Used as an oxidizer in analytical chemistry; its salts are used in explosives and electroplating baths; [Merck Index] Used as a catalyst, to make various esters, and in electrolytic bathes for lead deposition; [HSDB]
Electroplating [Category: Plate]
IN ANALYTICAL CHEMISTRY AS AN OXIDIZER & FOR SEPARATION OF POTASSIUM FROM SODIUM
EXPLOSIVES & FOR PLATING OF METALS /PERCHLORATE SALTS/
TITRATION REAGENT IN DETERMINATION OF 1H-BENZOTRIAZOLE IN AIR
CATALYST; MFR OF VARIOUS ESTERS; INGREDIENT OF ELECTROLYTIC BATH IN DEPOSITION OF LEAD
Methods of Manufacturing
...FROM POTASSIUM PERCHLORATE & SULFURIC ACID: HANDBOOK OF PREPARATIVE INORGANIC CHEMISTRY VOL 1, G BRAUER, ED (ACADEMIC PRESS, NEW YORK, 2ND ED, 1963) PAGES 318-320. COMPREHENSIVE MONOGRAPH: JC SCHUMACHER, PERCHLORATES (REINHOLD, NEW YORK, 1960).
Chemical reaction of sodium perchlorate and hydrochloric acid; direct electrolytic oxidation of cold (18 °C), very dilute (0.5N) hydrochloric acid; irradiating aqueous solutions of chlorine dioxide; passing ozonized air through a solution of hydrochloric acid or sodium hypochloride; electrodialysis of perchlorate salts using ion-selective membranes
Formulations/Preparations
GRADES: TECHNICAL; CP
...MARKETED ONLY IN MIXTURE WITH WATER CONTAINING 60-70% PERCHLORIC ACID, DENSITY 1.5 & 1.6, RESPECTIVELY.
DIOXONIUM PERCHLORATE SOLUTION; PERCHLORIC ACID SOLUTION
Technical grade, CP; commercial aqueous solutions contain 65-70% HClO4
General Manufacturing Information
Perchloric acid: ACTIVE
METHOD OF PURIFICATION: RECTIFICATION
응용 분야
용도Perchloric acid salts are used as explosivesand in metal plating. They are also used as anoxidizer and as a reagent in chemical analysis. These salts are produced by distillingpotassium chlorate with concentrated H2SO4under reduced pressure..
일반 설명A clear colorless odorless aqueous solution. Corrosive to metals and tissue. Closed containers may rupture violently under prolonged exposure to heat.
상·하류 제품 정보
상류 원료
하류 제품
관련 반응
연결된 노트
불러오는 중…