反应详情
EQUATION
反应方程式
REACTANTS
反应物
PRODUCTS
生成物
AUXILIARIES
试剂、催化剂与溶剂
PROCEDURE
实验过程
The 3-hexene feedstock was assumed to have a composition of 33 wt % cis-3-hexene and 67 wt % trans-3-hexene. The normal boiling points for 1-, 2-, and 3-hexene are listed in Example 2. The normal boiling for DMF, the extraction solvent in this example, is 152° C. (305° F.). The isomerization reaction was assumed to occur at the bottom of the column. The column was assumed to have 150 theoretical stages, a kettle reboiler, and a total condenser. The operating conditions for the column consisted of a pressure of 7 atm, condenser temperature of 140° C. (283° F.), and reboiler temperature of 232° C. (450° F.). In addition, 100 lb/hr of DMF was added to the 10th theoretical stage of the column (near the top). This resulted in a column with a diameter of 11.8 ft and a reflux ratio of 518. For this case, the 1000 lb/hr 3-hexene feed resulted in 980 lb/hr of 99 wt % 1-hexene product. The column bottoms contained 91 wt % DMF, which can be recycled back to the column. A detailed material balance is shown in the following table. RXFEED is the distillation column feed stream, SOLVENT is the DMF extractive distillation solvent stream, BOTTOMS is the distillation column bottoms stream, and 1-HEXENE is the product stream, which is obtained from the top of the column.
WORKUP
后处理
- customis 152° C.
- custom(305° F.)
- customThe isomerization reaction
- customconsisted of a pressure of 7 atm, condenser temperature of 140° C. (283° F.), and reboiler temperature of 232° C. (450° F.)
- customThis resulted in a column with a diameter of 11.8 ft