HRID1243126

反应详情

EQUATION

反应方程式

HRID 1243126 的结构方程式

AUXILIARIES

试剂、催化剂与溶剂

4

CONDITIONS

反应条件

温度
80 °C

PROCEDURE

实验过程

Nine 15 mL test tubes with screw threads were equipped with one 10×3 mm Teflon-coated stirring bar each and charged with K3PO4 (430 mg, 2.03 mmol) and one of the following copper sources: 1) copper powder, bronze (Aldrich, 99%; 3.2 mg, 0.050 mmol); 2) CuI (Strem, 98%; 9.6 mg, 0.050 mmol); 3) CuCl (Strem, 97+%; 5.0 mg, 0.050 mmol); 4) CuSCN (Aldrich, 98+%; 6.1 mg, 0.050 mmol); 5) Cu2O (Alfa Aesar, 99%; 3.6 mg, 0.025 mmol); 6) CuCl2 (Strem, 98%; 6.8 mg, 0.051 mmol); 7) CuSO4.5H2O (Aldrich, 98+%; 12.5 mg, 0.0501 mmol); 8) Cu(OAc)2 (Strem, 99%; 9.1 mg, 0.050 mmol); 9) Cu(II) acetylacetonate (Lancaster, 98%; 13.1 mg, 0.0500 mmol). Each test tube was closed with an open-top screw cap fitted with a Teflon-lined silicon rubber septum, evacuated through a 21-gauge needle, and then backfilled with argon. Meanwhile, a stock solution of 5-iodo-m-xylene (2.16 mL, 15.0 mmol), N-methylformamide (1.06 mL, 18.1 mmol), N,N′-dimethylethylenediamine (160 μL, 1.50 mmol) and dodecane (internal GC standard, 0.68 mL) in toluene (15 mL) was prepared in a 25 mL pear-shaped flask under argon. To each test tube was added 1.28 mL of the stock solution containing 1.0 mmol of 5-iodo-m-xylene, 1.2 mmol of N-methylformamide, 0.10 mmol of N,N′-dimethylethylenediamine using a syringe. The top of the septum was then covered with a dab of vacuum grease to seal the injection spot. The reaction mixtures in the test tubes were stirred in a 80±5° C. oil bath for 7 h. The test tubes were then allowed to reach room temperature, the screw caps were removed, and ethyl acetate (2 mL) was added. A 50–100 μL sample of the supernatant solution from each test tube was diluted with ethyl acetate (1 mL) and the resulting solutions were analyzed by GC. The results are reported in FIG. 21.

WORKUP

后处理

  1. customEach test tube was closed with an open-top screw
  2. customcap
  3. customevacuated through a 21-gauge needle
  4. customto seal the injection spot
  5. customto reach room temperature
  6. customthe screw caps were removed
  7. additionethyl acetate (2 mL) was added
  8. additionA 50–100 μL sample of the supernatant solution from each test tube was diluted with ethyl acetate (1 mL)